پهريون الرٽ SCO500

First Alert Logo: Protecting Homes & Families Since 1958

پهرين الرٽ SCO501CN-3ST وائرليس انٽرڪنيڪٽڊ ڪمبينيشن اسموڪ ۽ ڪاربن مونو آڪسائيڊ الارم يوزر مينوئل

Model: SCO500

1. تعارف

This manual provides essential information for the proper installation, operation, and maintenance of your First Alert SCO501CN-3ST Wireless Interconnected Combination Smoke and Carbon Monoxide Alarm. This device is designed to detect both smoke and carbon monoxide (CO) hazards, offering enhanced safety for your home. It features wireless interconnection capabilities, allowing multiple alarms to communicate and activate simultaneously throughout your residence.

2. حفاظت جي ڄاڻ

Carbon monoxide is an invisible, odorless, and deadly gas that can be produced by any fuel-burning appliance. CO alarms detect this poisonous gas and provide early warning. For maximum protection, it is recommended to use both ionization and photoelectric sensing technologies. This alarm incorporates a photoelectric smoke sensor, designed to reduce false alarms from cooking smoke or shower steam, and an advanced electrochemical CO sensor.

What Is Carbon Monoxide? Carbon monoxide is an invisible, odorless, and deadly gas that can be produced by any fuel-burning appliance. CO alarms detect this poisonous gas and provide early warning.

Common Sources of Carbon Monoxide

Carbon monoxide can originate from various household appliances and systems. Be aware of potential sources such as:

  • ڀتيون
  • خشڪ وينٽس
  • چمني
  • واٽر هيٽر
  • Gas stoves and ovens
  • باھمي
  • Automobiles in attached garages
Text: Common Sources of Carbon MonoxideIcon of a furnaceIcon of a dryer ventIcon of a chimney

تجويز ڪيل جڳهه

Install smoke alarms on every level of your home and in every bedroom. Carbon monoxide alarms should also be placed on every level and in every bedroom. Avoid placing alarms in 'dead zones' where walls and ceilings meet, as smoke detectors are less effective in these areas.

Diagram showing recommended placement of smoke alarms, CO alarms, and fire extinguishers in a house, including bedrooms, hallway, living room, kitchen, basement, and garage.

3. مصنوعات جون خاصيتون

  • Combination Detection: Detects both smoke and carbon monoxide.
  • وائرليس ڪنيڪشن: Connects with up to 18 other compatible First Alert alarms for a synchronized safety network.
  • Voice Location: Announces the type of threat and its location (e.g., "Fire in the Kitchen!"). Features 11 programmable locations.
  • Photoelectric Smoke Sensor: Designed to minimize false alarms from cooking or steam while effectively detecting smoldering fires.
  • Electrochemical CO Sensor: Provides accurate detection of carbon monoxide.
  • بيٽري هلائيندڙ: Easy installation without hardwiring.
  • هڪ بٽڻ آپريشن: A single button for testing the unit and silencing false alarms.
  • بلند آواز الارم: Emits an 85-decibel siren to alert occupants.
  • EZ Access Battery Drawer: Allows for easy battery replacement without removing the alarm from the ceiling.
First Alert SCO501CN-3ST Combination Smoke and Carbon Monoxide Alarm, front view.

سامهون view of the First Alert SCO501CN-3ST Combination Alarm.

4. سيٽ اپ

4.1. تنصيب

The alarm is battery-operated for easy installation. Mount the alarm securely to the ceiling or wall in accordance with local codes and the recommended placement guidelines. Ensure the mounting plate is firmly attached before twisting the alarm onto it.

4.2. بيٽري لڳائڻ

Your alarm requires two (2) AA batteries (included). To install or replace batteries:

  1. Locate the EZ access battery drawer on the side of the alarm.
  2. Open the battery drawer.
  3. Insert the two AA batteries, ensuring correct polarity (+ and -).
  4. Close the battery drawer until it clicks securely into place.

4.3. وائرليس انٽر ڪنيڪشن

To create a wireless safety network, follow the pairing instructions provided in the full user manual to interconnect this alarm with other compatible First Alert alarms. This allows all interconnected alarms to sound when one detects a hazard.

Video: Product Summary - Demonstrates key features and ease of use for the First Alert Combination Alarm.

5. آپريٽنگ

5.1. الارم جي جانچ ڪرڻ

Test your alarm weekly to ensure proper function. Press and hold the 'Test/Silence' button on the alarm until it sounds. The alarm will emit a loud 85-decibel sound and announce its status. If interconnected, all alarms should sound.

5.2. خاموشي جي خصوصيت

In case of a nuisance alarm (e.g., from cooking smoke), press the 'Test/Silence' button to temporarily silence the alarm. The alarm will reset after a few minutes if the smoke or CO levels return to normal.

5.3. الارم سگنل

The alarm provides distinct audible and voice alerts for different conditions:

  • تماڪ جي الارم: Three loud beeps followed by a voice announcement like "Fire! Fire!" and the location.
  • ڪاربن مونو آڪسائيڊ الارم: Four loud beeps followed by a voice announcement like "Warning! Carbon Monoxide!" and the location.
  • گھٽ بيٽري ڊيڄاريندڙ: One chirp every minute.
  • خرابي: Three chirps every minute.
  • زندگي جي پڄاڻي: Five chirps every minute.
Text: What does the beep mean?Icon for 4 beeps and a pause, indicating CO alarmIcon for 1 beep every minute, indicating low batteryIcon for 5 beeps every minute, indicating end of life

6. سار سنڀال

6.1. صفائي

Gently vacuum or use clean compressed air to remove accumulated dust monthly. Never use water, cleaners, or solvents, as these can damage the unit. If the alarm becomes excessively dirty, it may need to be replaced.

6.2. بيٽري مٽائڻ

Replace the two (2) AA batteries once a year, or immediately when the low battery warning (one chirp per minute) sounds. Refer to section 4.2 for battery installation instructions.

7. مسئلا حل ڪرڻ

If your alarm sounds, identify the type of alert based on the beeping pattern and voice announcement. Take appropriate action:

  • Smoke Alarm (3 beeps + voice): Immediately evacuate the premises and call emergency services (Fire Department or 911).
  • CO Alarm (4 beeps + voice): Immediately move to fresh air outdoors or by an open door/window. Call emergency services if symptoms persist.
  • Low Battery (1 chirp/minute): بيٽرين کي فوري طور تي تبديل ڪريو.
  • Malfunction (3 chirps/minute): Replace the alarm unit.
  • End of Life (5 chirps/minute): Replace the alarm unit.

8. وضاحتون

برانڊپهريون خبرداري
ماڊل نمبرSCO500
طاقت جو ذريعوبيٽري سان هلندڙ (2 AA بيٽريون شامل آهن)
پيداوار جي ماپ2"ڊي x 5"ڊي x 5"ايڇ
شيءِ جو وزن3.2 اونس
الارم جو قسمAudible (85 dB) with Voice Location
سينسر جو قسمڦوٽو اليڪٽرڪ (دونھون)، اليڪٽرو ڪيميڪل (CO)
ڪنيڪشنWireless, up to 18 compatible alarms
پاسي view of the First Alert SCO501CN-3ST Combination Alarm, showing dimensions of 5 inches width and 2 inches depth.

پاسي view with approximate dimensions.

9. وارنٽي ۽ سپورٽ

This First Alert alarm comes with a 7-year limited warranty. For warranty claims, technical support, or further assistance, please refer to the contact information provided in the original product packaging or visit the official First Alert webسائيٽ.