YUWELL YX303

Yuwell YX303 Fingertip Pulse Oximeter User Manual

ماڊل: YX303

1. تعارف

Thank you for choosing the Yuwell YX303 Fingertip Pulse Oximeter. This device is designed for non-invasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate. It is suitable for use in hospitals, homecare, outdoor activities, and sports. Please read this manual carefully before use to ensure safe and effective operation.

Yuwell YX303 Fingertip Pulse Oximeter

Image 1.1: The Yuwell YX303 Fingertip Pulse Oximeter. This image shows the compact device, typically with a display screen and a finger insertion area.

2. حفاظت جي ڄاڻ

اهم: This device is intended for non-medical use and is not a substitute for professional medical advice or diagnosis. Consult your physician for any medical concerns.

  • ايم آر آئي يا سي ٽي ماحول ۾ آڪسيميٽر استعمال نه ڪريو.
  • مسلسل نگراني جي ضرورت وارين حالتن ۾ آڪسيميٽر استعمال نه ڪريو.
  • Keep the device away from children. Small parts may be a choking hazard.
  • Do not use the oximeter on the same arm as a blood pressure cuff or arterial catheter.
  • Avoid placing the oximeter on fingers with nail polish, artificial nails, or excessive dirt, as this may affect accuracy.
  • Ensure the finger is clean and dry before use.

3. پراڊڪٽ ختمview

3.1. اهم خاصيتون

  • Low power consumption, simple to operate, light, and portable.
  • Oxygen saturation (SpO2) and Pulse Rate (PR) display.
  • Automatic power-off in 8 seconds when no finger is detected.
  • Pulse strength indicator.
  • Strong anti-interference capability.

3.2. ڊسپلي موڊس

The device features an OLED display. It shows:

  • Oxygen Saturation (SpO2) percentage.
  • Pulse Rate (BPM).
  • Pulse bar graph.

4. سيٽ اپ

4.1. بيٽري لڳائڻ

  1. ڊوائيس جي پٺي تي بيٽري جي ڪمري واري ڍڪ کي کوليو.
  2. Insert two (2) AAA 1.5V alkaline batteries, ensuring correct polarity (+ and -).
  3. بيٽري جي ڪمري واري ڍڪ کي محفوظ طور تي بند ڪريو.

ڊوائيس هڪ حجم اندر هلندي آهيtagاي رينج 2.6V کان 3.6V تائين.

5. آپريٽنگ هدايتون

  1. Ensure the oximeter has batteries installed.
  2. cl کوليوamp آڪسيميٽر جو.
  3. Insert one finger into the rubber opening of the oximeter, ensuring the finger is placed correctly and comfortably.
  4. cl جاري ڪريوamp. The oximeter will automatically turn on and begin measurement.
  5. ماپ دوران پنھنجو ھٿ ساڪن رکو. حرڪت درستگي کي متاثر ڪري سگھي ٿي.
  6. Read the SpO2 and Pulse Rate values displayed on the OLED screen.
  7. After removing your finger, the device will automatically power off after approximately 8 seconds.

5.1. Measurement Accuracy Considerations

  • آڪسيجن جي سنترپت: Accuracy is ±2% for readings between 70% and 99%. For readings below 70%, accuracy is not defined.
  • پلس جي شرح Accuracy is ±1% or ±1 BPM, whichever is greater.
  • Weak Perfusion: The oximeter can accurately display oxygen saturation and pulse rate even with a pulse filling degree as low as 0.6%.
  • روشني جي مداخلت: Compared to measurements in a dark room, the deviation in oxygen saturation under natural light and illuminated conditions is less than ±1%.

6. سار سنڀال

6.1. صفائي

  • آڪسيميٽر جي مٿاڇري کي نرم ڪپڙي سان صاف ڪريو dampened with medical alcohol (75% ethanol) or isopropyl alcohol.
  • ڊوائيس کي پاڻي يا ڪنهن به صفائي واري محلول ۾ نه ٻوڙيو.
  • ٻيهر استعمال ڪرڻ کان اڳ پڪ ڪريو ته ڊوائيس مڪمل طور تي سڪي ويو آهي.

6.2. اسٽوريج

  • آڪسيميٽر کي ٿڌي، سڪل جاءِ تي، سڌي سج جي روشني ۽ انتهائي گرمي پد کان پري رکو.
  • Remove batteries if the device will not be used for an extended period to prevent battery leakage.

7. مسئلا حل ڪرڻ

مسئلوممڪن سببحل
بجلي ڏيکارڻ بعد ڪوبه ڊسپلي نهبيٽريون مئل يا غلط نصب ٿيل آهن.Replace batteries or re-install them with correct polarity.
غلط پڙھڻFinger not inserted properly; excessive movement; nail polish; cold finger.Re-insert finger correctly; remain still; remove nail polish; warm finger.
"فنگر آئوٽ" يا ساڳيو غلطي پيغامآڱر نه ملي يا غلط طريقي سان رکيل هجي.Ensure finger is fully inserted into the sensor.

8. وضاحتون

پيرا ميٽرقدر
ڊسپلي موڊOLED ڊسپلي
SpO2 Measurement Range70% ~ 100%
SpO2 جي درستگي±2% (70%~99%), undefined (<70%)
نبض جي شرح جي ماپ جي حد25 ~ 250 بي پي ايم
نبض جي شرح جي درستگي±1% or ±1 BPM (whichever is greater)
بجلي جي فراهمي2 x AAA 1.5V الڪلائن بيٽريون
جلدtage حد2.6V ~ 3.6 وي
بجلي جو استعمال30 mA کان گھٽ
Weak Perfusion MeasurementSpO2 and PR can be displayed when pulse filling degree is 0.6%
خودڪار بند-بندAfter 8 seconds of no finger use
ٺاهيندڙYUWELL
ماڊل نمبرYX303 (Internal Item No: 31681163949)
پيڪيج جي ماپ11.52 x 7.21 x 3.8 سينٽي
وزن300 گرام (پيڪيجنگ سميت)

9. وارنٽي ۽ سپورٽ

For warranty information and customer support, please refer to the documentation provided with your purchase or contact your retailer. Keep your purchase receipt as proof of purchase.

© 2023 YUWELL. All rights reserved.