Elitech RCW-3200-TH

Elitech RCW-3200-TH Wireless Temperature and Humidity Data Logger User Manual

Model: RCW-3200-TH

1. پراڊڪٽ ختمview

The Elitech RCW-3200-TH is a wireless data collector designed for temperature and humidity monitoring. It operates as part of the RCW-3000 split network monitoring system, utilizing various communication technologies such as LoRa, 4G, Wi-Fi, and Ethernet. This system comprises wireless data collectors (like the RCW-3200-TH), gateways (RCW-3000), a cloud platform, and a mobile application.

The RCW-3200-TH sensor can be flexibly deployed in various monitoring locations. The RCW-3000 gateway facilitates data upload to the cloud platform via 4G, Wi-Fi, or Ethernet. This integrated system enables remote data viewing, historical data querying, and remote alarm notifications through the cloud platform and mobile application.

The RCW-3000 network monitoring system is suitable for applications in large-scale cold storage facilities, shaded storage areas, hospitals, and fresh produce supermarkets.

Diagram showing Elitech RCW-3200 sensors communicating wirelessly with an RCW-3000 gateway in a warehouse setting.

Figure 1: Elitech RCW-3200 sensors deployed in a warehouse, communicating with an RCW-3000 gateway. The system supports up to 100 sensors with a 1-minute upload interval.

2. اهم خاصيتون

  • وائرلیس رابطي Eliminates the need for extensive wiring, simplifying installation. Supports wireless data transmission up to 1000 meters in visible distance.
  • وڌايل بيٽري جي زندگي: Equipped with a 3200mAh rechargeable lithium battery, providing over 12 months of operation with a 10-minute or 3-minute upload interval.
  • گهڻن رابطي جا اختيار: Offers flexible 4G and Wi-Fi connectivity, allowing adaptation to various environmental communication requirements.
  • الارم نوٽيفڪيشن: Supports email, SMS, and mobile application alarm notifications. The Elitech App (available for iOS and Android) enables remote parameter settings and device management.
  • Cloud Data Service: The standard plan provides email alerts, remote settings, and 30 days of data review and storage. Advanced and professional plans offer extended data storage (3-5 years), data export, and user management.

3. ڊوائيس جي ترتيب

Familiarize yourself with the components of the RCW-3200-TH sensor:

سامهون view of the Elitech RCW-3200-TH data logger with labels for LCD screen, power button, unit switch button, USB interface, charging indicator, status indicator, bracket, and built-in sensor.

شڪل 2: سامهون view of the RCW-3200-TH device components.

  • چارجنگ اشارو: چارج جي حالت کي اشارو ڪري ٿو.
  • حالت اشارو: Displays device operational status.
  • LCD اسڪرين: Shows real-time temperature, humidity, time, and logging status.
  • پاور بٽڻ: Used to power the device on or off.
  • بریکٹ: For mounting the device.
  • اندروني سينسر: Integrated temperature and humidity sensor.
  • يونٽ سوئچ بٽڻ: Toggles between Celsius (°C) and Fahrenheit (°F).
  • USB انٽرفيس: Micro USB port for charging and data export.
پوئتي view of the Elitech RCW-3200-TH data logger showing a QR code, GUID numbers, and four strong magnets for mounting.

شڪل 3: پوئتي view of the RCW-3200-TH device, showing the QR code for app integration and magnetic mounts.

  • آر آر ڪوڊ: Used for scanning and adding the device to the mobile application.
  • GUID Numbers: Unique identification numbers for the device.
  • مضبوط مقناطيس: Four integrated magnets for secure mounting on metallic surfaces.

4. سيٽ اپ جون هدايتون

4.1 ڊوائيس تي پاور لڳائڻ

  1. Locate the Power Button on the side of the RCW-3200-TH device.
  2. Press and hold the Power Button until the LCD screen illuminates.
  3. Once powered on, the RCW-3200-TH will automatically attempt to connect to the RCW-3000 gateway. Ensure your RCW-3000 gateway is powered on and configured.
پاسي view of the Elitech RCW-3200-TH data logger highlighting the power button.

Figure 4: Location of the Power Button on the RCW-3200-TH.

4.2 ايپ انٽيگريشن

To integrate the sensor with the Elitech iCold cloud platform and mobile app:

  1. Ensure the RCW-3000 gateway is set up and connected to the internet.
  2. Download the Elitech iCold mobile application from your device's app store (iOS or Android).
  3. ايپ کوليو ۽ اڪائونٽ ٺاهيو يا لاگ ان ٿيو.
  4. Navigate to the device management section within the app.
  5. Select the option to add a new device. The app will prompt you to scan a QR code.
  6. Scan the QR code located on the back of your RCW-3200-TH device (refer to Figure 3).
  7. After scanning, the connected sensors should appear in the app automatically within approximately 10 minutes, provided the gateway is active and the sensor is powered on and within range.

4.3 ڊوائيس تي چڙهڻ

The RCW-3200-TH features four strong magnets on its back for easy mounting. Simply place the device on any suitable metallic surface. Ensure the device is positioned to allow for optimal signal transmission to the RCW-3000 gateway.

5. آپريٽنگ هدايتون

5.1 Reading Data on the LCD Screen

The LCD screen displays real-time temperature and humidity readings, along with other status indicators such as battery level and signal strength.

5.2 گرمي پد يونٽن کي تبديل ڪرڻ

Press the Unit Switch Button (labeled °C/°F) on the front of the device to toggle between Celsius and Fahrenheit temperature displays.

5.3 Data Logging and Upload Intervals

The device logs data at a default interval of 5 minutes, which is adjustable from 1 to 1440 minutes. Alarm log intervals are adjustable from 1 to 1440 minutes, with a default of 2 minutes. These settings can typically be configured remotely via the Elitech iCold cloud platform or mobile application.

5.4 Remote Monitoring via App/Cloud

Once the device is connected to the RCW-3000 gateway and integrated with the Elitech iCold platform, you can:

  • View real-time data from multiple sensors.
  • Access historical data and generate reports.
  • Set up alarm thresholds and receive notifications via email, SMS, or app push.
  • Adjust device parameters remotely.

6. سار سنڀال

6.1 بيٽري کي چارج ڪرڻ

The RCW-3200-TH is equipped with a 3200mAh rechargeable lithium battery. When the battery level is low, connect the device to a 5V/1A power source using a Micro USB cable. The charging indicator will show the charging status.

6.2 صفائي

Wipe the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the device. Ensure no liquids enter the USB port or sensor openings.

7. مسئلا حل ڪرڻ

  • ڊوائيس تي طاقت نه آهي: Ensure the battery is charged. Connect to a power source via Micro USB.
  • No data in app/cloud: Verify the RCW-3200-TH is powered on and within range of the RCW-3000 gateway. Check the gateway's internet connection (4G/Wi-Fi/Ethernet). Ensure the device has been correctly added to the app by scanning the QR code.
  • غلط پڙهڻ: Ensure the sensor is not obstructed and is placed in an area with proper air circulation. Avoid placing it near heat sources or direct sunlight.
  • Poor signal strength: Reposition the RCW-3200-TH or the RCW-3000 gateway to improve signal reception. Avoid physical obstructions between the sensor and gateway.

8. ٽيڪنيڪل وضاحتون

تفصيلقدر
ماڊل نمبرRCW-3200-TH
درجه حرارت جي ماپ جي حد-20 ~ 50 ℃
نمي جي ماپ جي حد0 ~ 99% RH
لاگ انٽال1~1440 min (adjustable, 5 min by default)
Alarm Log Interval1~1440 min (adjustable, 2 min by default)
رکڻ جي گنجائش32,000 ڊيٽا پوائنٽ
Charging/Data Exportمائڪرو USB
ڪم جي فريڪئنسي470~510 MHz ISM Frequency Band
بيٽري جي گنجائش3200mAh ريچارجبل ليتيم بيٽري
پاور ان پٽ5V/1A
تحفظ جو درجوIP65
طول و عرض110 x 70 x 18 ملي ايم (4.33 x 2.76 x 0.71 انچ)
وزن226.8 جي
بيٽريون شامل آهنها (1 ليتيم آئن بيٽري)

9. سپورٽ

For technical assistance or support, Elitech offers 24/7 US Technician Support via email and phone. Please refer to the Elitech official webرابطي جي تفصيل لاءِ سائيٽ.