Tyenaza ETCR2100A+

Tyenaza ETCR2100A+ Digital Clamp Resistance Tester User Manual

Model: ETCR2100A+

1. تعارف

This manual provides essential instructions for the safe and effective operation of the Tyenaza ETCR2100A+ Digital Clamp Resistance Tester. This device is designed for accurate measurement of grounding resistance and circuit resistance, featuring a dustproof and shockproof structure for reliable performance in various industrial and departmental settings.

Please read this manual thoroughly before using the instrument to ensure proper handling and to prevent damage or injury.

Tyenaza ETCR2100A+ Digital Clamp مزاحمتي جاچ ڪندڙ

Image 1.1: The Tyenaza ETCR2100A+ Digital Clamp Resistance Tester, showing its overall design with the clamp jaw and control panel.

2. حفاظت جي ڄاڻ

Always observe the following safety precautions to avoid electric shock, injury, or damage to the instrument:

  • Do not use the instrument if it appears damaged or is operating abnormally.
  • آپريشن کان اڳ پڪ ڪريو ته بيٽري جو ڪمپارٽمينٽ محفوظ طور تي بند ٿيل آهي.
  • Do not attempt to measure live circuits beyond the specified voltage limits (CAT III 150V).
  • Avoid using the instrument in wet environments or during thunderstorms.
  • Refer to qualified personnel for any repairs or servicing.
  • Keep the instrument away from strong magnetic fields and electric fields exceeding specified limits.

3. پيڪيج مواد

پڪ ڪريو ته سڀئي شيون پيڪيج ۾ موجود آهن:

  • 1 x ETCR2100A+ Digital Clamp مزاحمتي جاچ ڪندڙ
  • 1 x Accessory (likely a test ring or similar calibration aid)
  • 1 x استعمال ڪندڙ دستياب (هي دستاويز)
  • 1 x اسٽوريج باڪس

Note: 1.5V AA batteries (x4) are required and are not included in the package.

ETCR2100A+ Digital Clamp Resistance Tester with included accessory

Image 3.1: The ETCR2100A+ tester shown with a standard test ring, which is typically included as an accessory for calibration or verification.

4. مصنوعات جون خاصيتون

The ETCR2100A+ Digital Clamp Resistance Tester offers the following key features:

  • ملٽي فنڪشنل ڊسپلي: Resistance and current values are displayed simultaneously on a new black luxury screen.
  • اعلي درستگي: Microprocessor-controlled for precise grounding resistance detection, utilizing fast filtering technology to minimize interference.
  • ڊيٽا جو انتظام: Features real-time clock, data storage for up to 99 sets, and data retrieval capabilities.
  • ٻڌڻ ۽ ڏسڻ جو الارم: "Beep beep beep" alarm sound with adjustable threshold settings for resistance (1-199 Ω) and current (1-499mA).
  • خودڪار ڪم: Automatic shutdown and fully automatic gear shifting for ease of use.
  • مضبوط ڊيزائن: Shockproof and dustproof structure, suitable for demanding industrial environments.
  • وسيع ايپليڪيشن: Ideal for telecommunications, power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, and lightning rod systems.
بند ڪرڻ view ڪل جوamp jaws of the ETCR2100A+ tester

تصوير 4.1: هڪ ويجهو تصوير view مضبوط ڪل جوamp jaws, highlighting the double insulation and structural features designed for durability and safety.

5. سيٽ اپ

5.1 بيٽري لڳائڻ

The ETCR2100A+ requires four (4) 1.5V AA batteries (not included).

  1. Locate the battery compartment cover on the back of the instrument.
  2. Use a suitable tool (if necessary) to open the battery compartment.
  3. Insert four 1.5V AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. بيٽري جي ڪمري واري ڍڪ کي محفوظ طور تي بند ڪريو.

5.2 شروعاتي پاور آن

بيٽري لڳائڻ کان پوءِ، دٻايو آن/بند button to power on the device. The LCD display will illuminate, indicating the device is ready for use.

6. آپريٽنگ هدايتون

6.1 بنيادي ماپ

To perform a grounding resistance test:

  1. پڪ ڪريو ته اوزار فعال آهي.
  2. cl کوليوamp ٽرگر کي دٻائڻ سان جبڙن کي بند ڪريو.
  3. cl رکيamp around the grounding conductor or circuit to be measured. Ensure the jaws are fully closed around the conductor.
  4. The resistance value will be displayed on the LCD screen. The device features fully automatic shifting.
  5. The single measurement time is approximately 0.5 seconds.
ETCR2100A+ tester clamping an insulated ground wire

Image 6.1: The ETCR2100A+ tester shown clamping an insulated ground wire, demonstrating its capability to accurately test even insulated conductors.

6.2 Single Point Grounding System, Auxiliary Measurement

For single point grounding systems where direct clamp measurement of the lead wire is not feasible, auxiliary methods can be used. The two-point method is illustrated below:

Diagram illustrating the two-point auxiliary measurement method for single point grounding systems

Image 6.2: Diagram showing the two-point method for auxiliary grounding resistance measurement. It depicts a grounding rod (RA) connected to a single point, with a wire extending to a natural grounding point (e.g., water pipe, buried metal) for measurement.

هن طريقي کي استعمال ڪرڻ لاء:

  • Identify a natural grounding point with a low resistance value near the grounding point to be measured. Examples include a water pipe, fire hydrant, or other deeply buried metal structure.
  • Connect a wire from the point to be measured to this auxiliary grounding point.
  • Clamp the ETCR2100A+ around the connecting wire to perform the measurement.
ETCR2100A+ Digital Clamp Resistance Tester in an industrial substation environment

Image 6.3: The ETCR2100A+ tester positioned in an industrial substation, illustrating a typical application environment for grounding resistance measurement.

6.3 Data Storage and Retrieval

The instrument can store up to 99 sets of measurement data.

  • To store data: After a measurement, press the ايم ايم button to save the current reading.
  • To retrieve data: Press the ايم ايم button repeatedly to cycle through stored data.

6.4 الارم فنڪشن

The ETCR2100A+ features an audible and visual alarm for out-of-range measurements.

  • To activate/deactivate the alarm: Press the AL بٽڻ
  • To set alarm thresholds: Refer to the device's on-screen menu or specific instructions for setting resistance (1-199 Ω) and current (1-499mA) alarm limits.
Hand holding the ETCR2100A+ Digital Clamp مزاحمتي جاچ ڪندڙ

Image 6.4: A hand holding the ETCR2100A+ tester, demonstrating its ergonomic design and ease of handling during operation.

7. سار سنڀال

7.1 صفائي

Wipe the instrument's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off before cleaning.

7.2 اسٽوريج

When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in its provided storage box in a cool, dry place, away from direct sunlight and extreme temperatures.

7.3 حساب ڪتاب

Regular calibration by qualified personnel is recommended to maintain measurement accuracy, especially after prolonged use or if accuracy is suspected to be compromised.

8. مسئلا حل ڪرڻ

مسئلوممڪن سببحل
ڊوائيس تي طاقت نه آهي.مئل يا غلط طور تي نصب ٿيل بيٽريون.Replace batteries with new 1.5V AA batteries, ensuring correct polarity.
غلط پڙھڻ.Jaws not fully closed; interference from external fields; dirty jaws; need for calibration.Ensure jaws are fully closed. Move away from strong magnetic/electric fields. Clean jaws. Consider professional calibration.
الارم جو آواز مسلسل.Measurement exceeds set alarm threshold.Check the measured value against the set alarm limits. Press the AL button to silence or deactivate the alarm.
ڊسپلي خالي آهي يا ٽمٽار آهي.Low battery power; environmental conditions (extreme temperature/humidity).Replace batteries. Operate within specified temperature and humidity ranges (-20 ℃ to 55 ℃; 10% RH to 90% RH).

9. وضاحتون

ماڊلETCR2100A+
فنڪشنGrounding resistance test, circuit resistance test, leakage current test
مزاحمت جي حد0.01 Ω کان 200 Ω
مزاحمت جي قرارداد0.001 اي
موجوده حدNone (for leakage current test, the range is 1-499mA for alarm setting)
ڊيٽا اسٽوريج99 سيٽ
Alarm Threshold Setting Range (Resistance)1-199 Ω
Alarm Threshold Setting Range (Current)1-499 ايم اي
ڪم ڪندڙ حرارت ۽ نمي-20 ℃ to 55 ℃; 10% RH to 90% RH
LCD ڊسپلي4 digit LCD digital display
ڊسپلي سائيزApprox. 47 x 28.5mm / 1.85 x 1.12in (L x W)
Jaw Size (Round)Approx. 32mm / 1.26in diameter
Jaw Opening Size (Long)تقريبن 32 ملي ميٽر / 1.26 انچ
Clamp Size (Long Jaw)تقريبن 260 x 90 x 56 ملي ميٽر / 10.24 x 3.54 x 2.2 انچ
تحفظ جي سطحٻيڻو موصليت
ساخت جون خاصيتونClamp shaped CT
گيئر شفٽنگFully automatic shifting
خارجي مقناطيسي ميدان<40A/m
خارجي اليڪٽرڪ فيلڊ<1V/m
Single Measurement Time0.5 سيڪنڊ
Resistance Measurement FrequencyGreater than 1KHz
Tested Current Frequency50/60Hz automatic
بجلي جي فراهمي4 x 1.5V AA بيٽريون (شامل نه آھن)
موادABS
شيءِ جو وزن2.13 ڪلوگرام / 4.69 پائونڊ

10. وارنٽي ۽ سپورٽ

وارنٽي جي معلومات، ٽيڪنيڪل سپورٽ، يا سروس جي پڇا ڳاڇا لاءِ، مھرباني ڪري پنھنجي پرچون ڪندڙ يا ٺاھيندڙ سان سڌو رابطو ڪريو. خريداري جي ثبوت طور پنھنجي خريداري جي رسيد رکو.

Manufacturer: Tyenaza

© 2023 Tyenaza. All rights reserved.