EARU EARU-1006

EARU Electric Single Phase Energy Meter 220V 80A Instruction Manual

Model: EARU-1006

1. تعارف

The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.

2. حفاظت جي ڄاڻ

  • مقامي اليڪٽريڪل ڪوڊس ۽ ضابطن جي مطابق، انسٽاليشن هڪ قابل اليڪٽريشن طرفان ڪئي وڃي.
  • Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
  • جيڪڏهن ڊوائيس خراب نظر اچي ته ان کي نه هلايو.
  • This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
  • The maximum current rating is 80A. Do not exceed this limit.

3. پراڊڪٽ ختمview

The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

EARU Electric Single Phase Energy Meter front view LCD ڊسپلي سان

شڪل 1: سامهون view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Close-up of EARU Electric Energy Meter LCD display showing readings

شڪل 2: تفصيلي view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.

4. پيڪيج مواد

پيڪيج ۾ عام طور تي شامل آهن:

  • 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)

5. وضاحتون

Technical data table for EARU Electric Energy Meter

Figure 3: Technical data table providing detailed specifications of the energy meter.

ٽيڪنيڪل وضاحتون
پيرا ميٽرقدر
برانڊاي آر يو
ماڊلEARU-1006
درجه بندي VoltageAC110V/220V (230 Volts)
موجوده درجه بندي80A
تعدد50/60Hz
ماپ جي درستگي±1% / Class 1
بجلي جو استعمال<2W
تنصيب35 ايم ايم ڊن ريل
ڪم ڪندڙ درجه حرارت-10°C کان +55°C
اسٽوريج جي درجه حرارت-40°C کان +70°C
ڪم ڪندڙ نمي5٪ کان 95٪ RH
ڊسپلي جو قسمايل سي ڊي
Max kWh Record999999kWh
پيداوار جي ماپ10 x 5 x 10 سينٽي
شيءِ جو وزن450 جي
Dimensions of EARU Electric Energy Meter in millimeters and inches

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.

6. سيٽ اپ ۽ تنصيب

اهم: پڪ ڪريو ته انسٽاليشن سان اڳتي وڌڻ کان اڳ سموري طاقت ختم ٿي وئي آهي.

  1. چڙهڻ: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
  2. وائرنگ: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
    • Connect the Live (L) input wire to the designated 'L In' terminal.
    • Connect the Neutral (N) input wire to the designated 'N In' terminal.
    • Connect the Live (L) output wire to the designated 'L Out' terminal.
    • Connect the Neutral (N) output wire to the designated 'N Out' terminal.
  3. پاور آن: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.
Wiring diagram for EARU Electric Single Phase Energy Meter

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.

7. آپريٽنگ هدايتون

The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.

  • Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
  • kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
  • kWh Reset: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.

8. سار سنڀال

  • صفائي: ميٽر جي ٻاهرين حصي کي صاف ڪرڻ لاءِ نرم، سڪل ڪپڙو استعمال ڪريو. رگڙيندڙ ڪلينر يا سالوينٽس استعمال نه ڪريو.
  • چڪاس: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
  • ماحول: پڪ ڪريو ته آپريٽنگ ماحول مخصوص درجه حرارت ۽ نمي جي حدن اندر رهي.

9. مسئلا حل ڪرڻ

مسئلوممڪن سببحل
ڊسپلي خالي آهيNo power supply; Incorrect wiringCheck power connections and ensure power is supplied. Verify wiring against the diagram.
غلط پڙھڻIncorrect wiring; Faulty connectionDouble-check all wiring connections. Ensure wires are securely fastened.
kWh not accumulatingNo load connected; Meter malfunctionEnsure there is an active electrical load connected through the meter. If problem persists, contact support.

10. وارنٽي ۽ سپورٽ

The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's webرابطي جي تفصيل لاءِ سائيٽ.

© 2023 EARU Electric. All rights reserved.