mypin DA8-RRB

mypin DA8-RRB Digital Sensor Meter Instruction Manual

Multi-Functional Intelligent LED Display with 2 Relay Alarm Output

1. تعارف

The mypin DA8-RRB is a versatile digital sensor meter designed for precise measurement and monitoring of various industrial signals. It features a clear 4-digit LED display for Process Value (PV) and Set Value (SV), and supports multiple input types including 0-75mV, 4-20mA, and 0-10V. Equipped with two relay alarm outputs, this meter provides stable performance and is easy to operate, making it suitable for integration with a wide range of sensors such as transformers, pressure sensors, weighing sensors, and more.

2. حفاظت جي ڄاڻ

  • ڪنهن به وائرنگ ڪنيڪشن ٺاهڻ يا سار سنڀال ڪرڻ کان اڳ هميشه بجلي بند ڪريو.
  • Ensure all wiring is done by qualified personnel and complies with local electrical codes.
  • تصديق ڪريو پاور سپلائي voltage matches the meter's specifications (90-265V AC/DC).
  • Avoid exposing the device to excessive moisture, dust, or extreme temperatures.
  • Do not attempt to open or repair the device yourself; refer to qualified service personnel.
  • برقي جھٽڪو کي روڪڻ لاءِ مناسب گرائونڊنگ کي يقيني بڻايو وڃي.

3. پراڊڪٽ ختمview

3.1 فرنٽ پينل

Front panel of mypin DA8-RRB Digital Sensor Meter
Figure 1: Front panel showing PV/SV displays, control buttons, and alarm indicators (AL1, AL2, OUT).

The front panel features a large 4-digit LED display for the Process Value (PV) and a smaller 4-digit LED display for the Set Value (SV). Control buttons include SET, <<RST (Reset/Shift), Up arrow, and Down arrow for configuration and operation. Indicators for AL1, AL2 (Alarm 1, Alarm 2), and OUT (Output) are also present.

3.2 Rear Panel and Terminals

Rear panel with terminal block and wiring diagram
شڪل 2: پوئتي view of the meter, detailing the terminal block for power, input, and output connections, along with product specifications.

The rear panel houses the terminal block for all electrical connections, including power input, auxiliary power, sensor inputs, and relay outputs. A detailed wiring diagram is provided on the label for easy installation.

3.3 چڙهڻ واري ڪلپس

پاسي view of the meter with mounting clips
شڪل 3: پاسي view showing the included mounting clips for panel installation.

The meter comes with mounting clips for secure panel installation. These clips slide into grooves on the side of the meter and are tightened to hold the unit in place.

4. وضاحتون

پيرا ميٽرتفصيل
ماڊلDA8-RRB
انٽرويو سگنل0-75mV, 4-20mA, 0-10V
بجلي جي فراهمي90-265V AC/DC
معاون بجلي جي فراهمي24V ڊي سي
بجلي جو استعمال3W کان گھٽ
درستگي0.3%F.S ±2dgt
Sampلنگ جي شرح≤8 times/second
الارم ٻاھر2 x RELAY (Normal Open, AC250V/3A or DC 30V/3A COS=1)
اينالاگ آئوٽ4-20mA (Wiring not explicitly shown on provided diagram)
طول و عرض (W x H x D)48mm x 96mm x 80mm
وزن171 جي
موادABS

5. سيٽ اپ

5.1 تنصيب

  1. Prepare a panel cutout of appropriate dimensions for the meter (typically 45mm x 92mm, though not explicitly stated, this is standard for 48x96mm meters).
  2. Insert the meter into the panel cutout from the front.
  3. Slide the provided mounting clips into the grooves on the sides of the meter from the rear.
  4. Tighten the screws on the mounting clips to secure the meter firmly in the panel.

5.2 وائرنگ ڊاگرام

Detailed wiring diagram on the meter's rear label
Figure 4: Close-up of the wiring diagram on the rear label. Refer to this diagram for all electrical connections.

5.3 ٽرمينل ڪنيڪشن

Refer to Figure 4 and the following instructions for correct wiring:

ٽرمينل نمبروصفنوٽس
1، 2Power Supply (90-265V AC/DC)Connect to main power source.
3، 4Auxiliary Power (24V DC)For external devices or sensors requiring 24V DC.
5، 6Alarm Output 1 (AL1)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
7، 8Alarm Output 2 (AL2)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
9Common (com.mV.mA.V)Common terminal for mV, mA, and V inputs.
10mV / mA InputConnect positive terminal of 0-75mV or 4-20mA sensor here.
11جلدtagاي ان پٽ (V)Connect positive terminal of 0-10V sensor here.
12مثبت (+)Typically for 4-wire sensors or external sensor power.

اهم: Ensure correct polarity for all input signals. Incorrect wiring can damage the meter or sensor.

6. آپريٽنگ هدايتون

6.1 پاور کوليو

After completing all wiring, apply power to the meter. The LED displays will illuminate, showing the current Process Value (PV) and potentially a Set Value (SV).

6.2 بٽڻ جا ڪم

  • سيٽ بٽڻ: پيرا ميٽر سيٽنگ موڊ ۾ داخل ٿيڻ ۽ چونڊن جي تصديق ڪرڻ لاءِ استعمال ڪيو ويندو آهي.
  • <<RST button: Used to shift digits during value setting or to reset certain functions.
  • Up (↑) button: Used to increase values or navigate through menu options.
  • Down (↓) button: Used to decrease values or navigate through menu options.

6.3 Basic Operation (General)

While specific programming steps are not detailed in the provided information, typical operation involves:

  1. Viewing PV/SV: The main display shows the current Process Value (PV). The smaller display shows the Set Value (SV), which might be an alarm setpoint or other configured parameter.
  2. سيٽنگ پيٽرولر: Press the SET button to enter the parameter setting mode. Use the Up/Down arrows to select parameters and adjust their values. Use the <<RST button to shift between digits when setting numerical values. Press SET again to confirm and save changes.
  3. الارم فنڪشن: The AL1 and AL2 indicators will light up when the measured PV exceeds or falls below their respective setpoints, triggering the corresponding relay outputs.

For detailed parameter configuration, refer to the full product manual (if available from the manufacturer) or contact technical support.

7. سار سنڀال

  • صفائي: ڊسپلي کي نرميءَ سان صاف ڪريو ۽ casing نرم، سڪل ڪپڙي سان. گھڙڻ وارا صاف ڪندڙ يا محلول استعمال نه ڪريو.
  • ڪنيڪشن چيڪ: وقتي طور تي سڀني وائرنگ ڪنيڪشنن جو معائنو ڪريو ته جيئن يقيني بڻائي سگهجي ته اهي محفوظ ۽ سنکنرن کان پاڪ آهن.
  • ماحولياتي حالتون: پڪ ڪريو ته آپريٽنگ ماحول مخصوص درجه حرارت ۽ نمي جي حدن اندر رهي ته جيئن ڊوائيس جي زندگي کي ڊگهو ڪري سگهجي.

8. مسئلا حل ڪرڻ

مسئلوممڪن سببحل
ميٽر چالو نٿو ٿئي.بجلي جي فراهمي نه آهي يا غلط وائرنگ.Check power connections (Terminals 1, 2) and ensure voltage is within 90-265V AC/DC.
Display shows "----" or erratic readings.Incorrect sensor wiring, sensor malfunction, or wrong input type selected.Verify sensor connections (Terminals 9-12) and ensure the sensor is functioning correctly. Check meter configuration for correct input signal type.
Alarm outputs (AL1/AL2) not activating.Alarm setpoints incorrect or relay wiring issue.Check alarm setpoints (SV) and ensure they are configured correctly relative to the PV. Verify wiring to external alarm devices (Terminals 5-8).
غلط پڙھڻ.Sensor calibration issue or environmental interference.Calibrate the sensor if possible. Ensure the meter is not exposed to strong electromagnetic interference.

9. استعمال ڪندڙ ٽوٽڪا

  • Input Signal Selection: Before connecting your sensor, ensure the meter is configured for the correct input signal type (mV, mA, or V) to avoid incorrect readings or potential damage.
  • صاف ليبلنگ: For complex setups, clearly label all wires connected to the terminal block to simplify future troubleshooting or maintenance.
  • ٽيسٽ الارم: After setting alarm points, perform a test to ensure the relay outputs activate as expected.

10. وارنٽي ۽ سپورٽ

وارنٽي جي معلومات، ٽيڪنيڪل سپورٽ، يا سروس جي پڇا ڳاڇا لاءِ، مھرباني ڪري پنھنجي خريداري واري جاءِ يا ٺاھيندڙ سان سڌو رابطو ڪريو. خريداري جي ثبوت طور پنھنجي خريداري جي رسيد رکو.

لاڳاپيل دستاويز - DA8-RRB

اڳيview MYPIN D Series Intelligent Sensor Meter Instruction Manual | Specifications & Wiring
Comprehensive instruction manual for the MYPIN D Series Intelligent Sensor Meter. Covers specifications, operation, parameter setting, wiring diagrams, and troubleshooting for models like DM8A, DK8A, and DM8E.
اڳيview MYPIN DW سيريز سنگل فيز پاور ميٽر هدايت نامو - ٽيڪنيڪل گائيڊ
MYPIN DW سيريز سنگل فيز پاور ميٽر لاءِ جامع هدايت نامو. وضاحتون، آپريشن، وائرنگ ڊاگرام، پيرا ميٽر سيٽنگون، ۽ صحيح بجلي جي ماپ لاءِ ايپليڪيشنون شامل آهن.
اڳيview MYPIN LM سيريز وزن ڪنٽرولر هدايتون ۽ موڊبس استعمال ڪندڙ هدايتون
MYPIN LM سيريز وزن ڪنٽرولر لاءِ جامع گائيڊ، انسٽاليشن، آپريشن، پيرا ميٽر سيٽنگون، ۽ موڊبس ڪميونيڪيشن پروٽوڪول کي ڍڪيندي. تفصيلي وضاحتون، آرڊرنگ جي معلومات، ۽ ماؤنٽنگ طول و عرض شامل آهن.
اڳيview MYPIN FH سيريز انٽيليجنٽ ميٽرز: فريڪوئنسي، ٽيچو، ڳڻپ، بيچ - ٽيڪنيڪل وضاحتون
MYPIN FH سيريز انٽيليجنٽ ميٽرز لاءِ جامع ٽيڪنيڪل وضاحتون، خاصيتون، ۽ آپريشنل موڊس، جن ۾ فريڪوئنسي، ٽيچو، ڳڻپ، ۽ بيچ فنڪشن شامل آهن. هي دستاويز طول و عرض، پيرا ميٽرز، ۽ ڪنيڪشن ڊاگرام جي تفصيل ڏئي ٿو.
اڳيview MYPIN FH سيريز ڪائونٽر/ڊگھائي/بيچ ميٽر هدايت نامو
ڪائونٽر، ڊيگهه، ۽ بيچ ميٽرن جي MYPIN FH سيريز لاءِ هدايت نامو. ماڊل FH4، FH7، ۽ FH8 لاءِ وضاحتون، خاصيتون، آرڊرنگ، آپريشن، ان پٽ/آئوٽ پٽ موڊس، ۽ ٽرمينل ڪنيڪشن شامل آهن.
اڳيview MYPIN FH/FC سيريز ڊجيٽل ڪائونٽر ۽ ڊيگهه ميٽر - وضاحتون ۽ دستور
MYPIN FH/FC سيريز ڊجيٽل ڪائونٽر ۽ ڊيگهه ميٽرن لاءِ جامع دستور. تفصيل وضاحتون، آرڊرنگ ڪوڊ، آپريشن، پيرا ميٽر سيٽنگون، ۽ ماڊلز FH4، FH6، FH7، FH8، FH9، FH10 لاءِ ٽرمينل ڪنيڪشن.