1. تعارف
The Pilz PNOZ s3 is a compact safety relay designed for monitoring safety functions in industrial applications. It is specifically engineered to monitor E-STOP pushbuttons, safety gates, and light grids, ensuring the safe operation of machinery by reliably detecting and reacting to hazardous conditions. This manual provides essential information for the proper installation, operation, and maintenance of the PNOZ s3 safety relay.
2. حفاظت جي ڄاڻ
اهم: Read and understand all safety instructions before installing, operating, or performing maintenance on the PNOZ s3 safety relay. Failure to comply with these instructions may result in serious injury or death, and/or damage to the equipment.
- Installation and commissioning must only be carried out by qualified and authorized personnel.
- Always disconnect power to the device and the machine before performing any installation, wiring, or maintenance work.
- Adhere to all local and national safety regulations, standards, and directives (e.g., EN ISO 13849-1, IEC 62061).
- Do not bypass or modify safety functions.
- Ensure proper grounding and protection against electrical hazards.
3. پراڊڪٽ ختمview
The Pilz PNOZ s3 safety relay features a compact design with clearly labeled terminals and status indicators on the front panel. It is designed for plug-in mounting, allowing for easy installation and replacement.

شڪل 1: سامهون view of the Pilz PNOZ s3 Safety Relay, showing input/output terminals and status indicators.
3.1. ٽرمينلز
The relay is equipped with screw terminals for secure electrical connections. Key terminals include:
- A1، A2: Power supply connection (24VDC).
- S11, S12, S21, S22, S34: Input terminals for connecting safety devices such as E-STOP buttons, safety gates, or light grids.
- 13, 14; 23, 24; 33, 34: Safety output contacts (Normally Open, n/o) for controlling contactors or other safety-related parts of the control system.
- Y32: ان پٽ ري سيٽ ڪريو.
3.2. اشارا
The front panel includes LED indicators to provide status information:
- طاقت: Indicates power supply status.
- In1, In2: Indicate the status of the input circuits.
- ٻاهر: Indicates the status of the output contacts.
- تبديل ڪريو Indicates the status of the reset function.
- غلطي: Illuminates in case of an internal fault or wiring error.
4. سيٽ اپ ۽ تنصيب
4.1. چڙهڻ
The PNOZ s3 is designed for plug-in mounting onto a compatible base or DIN rail adapter. Ensure the mounting location is free from excessive vibration, moisture, and extreme temperatures. Allow adequate space for ventilation and wiring.
- پڪ ڪريو ته چڙهڻ واري سطح صاف ۽ سڪل آهي.
- Align the relay with the corresponding slots on the base unit or DIN rail adapter.
- Gently push the relay into place until it clicks securely.
4.2. وائرنگ
All wiring must be performed according to the provided wiring diagrams from PILZ and relevant electrical standards. Use appropriate wire gauges and ensure all connections are secure to prevent loose contacts.
- Connect the 24VDC power supply to terminals A1 (+) and A2 (-).
- Connect the safety device inputs (e.g., E-STOP, safety gate contacts) to the S11, S12, S21, S22, S34 terminals as per the application's safety circuit design.
- Connect the safety outputs (13/14, 23/24, 33/34) to the control circuit of the machine, typically to contactor coils or other safety-related components.
- Connect the reset circuit to terminal Y32 if an external manual reset is required.
- Verify all wiring connections for correctness and tightness before applying power.
5. آپريٽنگ هدايتون
Once properly installed and wired, the PNOZ s3 safety relay operates by monitoring the status of its input circuits. When all safety inputs are closed (e.g., E-STOP released, safety gate closed), and after a successful reset, the safety outputs will close, allowing the machine to operate. If any safety input opens, the outputs will immediately open, bringing the machine to a safe state.
5.1. شروعاتي پاور اپ ۽ ري سيٽ
- Apply power to the PNOZ s3. The 'Power' LED should illuminate.
- Ensure all safety inputs are in their safe (closed) state. The 'In1' and 'In2' LEDs should indicate the status of the input circuits.
- If configured for manual reset, activate the reset button connected to Y32. The 'Reset' LED will briefly illuminate, and then the 'Out' LED should turn on, indicating the safety outputs are closed.
- If configured for automatic reset, the outputs will close automatically once all safety inputs are in their safe state.
5.2. عام آپريشن
During normal operation, the 'Power', 'In1', 'In2', and 'Out' LEDs should be illuminated, indicating that the safety circuit is closed and the machine is enabled. If a safety function is activated (e.g., E-STOP pressed, safety gate opened), the corresponding input LED(s) will change state, and the 'Out' LED will turn off as the safety outputs open.
6. سار سنڀال
The Pilz PNOZ s3 safety relay is designed for minimal maintenance. Regular inspections are recommended to ensure continued safe operation.
- بصري چڪاس: Periodically check the relay for any signs of physical damage, discoloration, or loose connections.
- صفائي: If necessary, gently clean the exterior of the relay with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- فنڪشنل ٽيسٽ: Regularly test the safety functions connected to the relay (e.g., activate E-STOP, open safety gate) to ensure the relay responds correctly and brings the machine to a safe state.
7. مسئلا حل ڪرڻ
This section provides guidance for common issues encountered with the PNOZ s3 safety relay.
| علامتي | ممڪن سبب | حل |
|---|---|---|
| Fault indicator (LED) is on. | Internal fault, wiring error, or short circuit in the safety circuit. | Check wiring for shorts or open circuits. Verify power supply. If fault persists, contact PILZ support. |
| No power LED illumination. | بجلي جي فراهمي ناهي، غلط وولٽtage, or faulty wiring to A1/A2. | Verify 24VDC power supply. Check connections to A1 and A2. |
| Outputs not activating (Out LED off). | Safety inputs not closed, reset not performed, or internal fault. | Ensure all safety inputs are in their safe state. Perform a manual reset if required. Check input LEDs. |
| Inputs (In1, In2) LEDs not illuminating correctly. | Faulty safety device, wiring issue to input terminals, or incorrect input configuration. | Check the connected safety devices (E-STOP, safety gate). Verify wiring to S11, S12, S21, S22, S34. |
8. وضاحتون
Key technical specifications for the Pilz PNOZ s3 safety relay (Model: 750103):
- ماڊل نمبر: 750103
- برانڊ: PILZ
- پيداوار جي ماپ: 4.72 x 5.51 x 13.78 انچ؛ 3.49 اونس
- انٽ واليمtage: 24 وي ڊي سي
- ڪنيڪٽر جو قسم: پلگ ان
- مواد جو رابطو Silver Tungsten
- رابطي جو قسم: 2 Normally Open (n/o) safety contacts
- چڙهڻ جو قسم: پلگ ان ماؤنٽ
- درخواست: E-STOP, safety gates, light grids monitoring
9. وارنٽي ۽ سپورٽ
For detailed warranty information, please refer to the official PILZ warranty policy available on their website or contact your authorized PILZ distributor. In case of technical issues or questions not covered in this manual, please contact PILZ technical support for assistance. Ensure you have the model number (750103) and serial number of your device ready when contacting support.
PILZ Official Webسائيٽ: www.pilz.com