1. تعارف
The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.
2. پراڊڪٽ ختمview
The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

شڪل 1: مٿي کان هيٺ view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

شڪل 2: زاويه view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.
3. خاصيتون
- Eight individually fused outputs for device protection.
- انٽ واليمtage: 12 to 24 Volt AC or DC.
- اوٽ وولٽtage: 12 to 24 Volt AC or DC.
- UL Recognized and UL294 compliant for access control applications.
- Constructed from durable Phenolic or Fiberglass material.
- Compact dimensions for easy integration.
4. وضاحتون
| تفصيل | تفصيل |
|---|---|
| ماڊل نمبر | ACM8 |
| پيداوار جي ماپ (L x W x H) | 8 x 4.5 x 1.25 انچ |
| انٽ واليمtage | 12 to 24 Volt AC or DC |
| اوٽ وولٽtage | 12 to 24 Volt AC or DC |
| ٻاھرين جو تعداد | 8 (Fused) |
| مواد | Phenolic or Fiberglass |
| معيار | UL RECOGNIZED, UL294 |
| شيءِ جو وزن | 11.2 اونس |
| ٺاهيندڙ | ALTRONIX |
5. سيٽ اپ
- يونٽ لڳائڻ: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
- پاور ڪنيڪشن: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
- Connectاھر ڪنيڪشن: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
- ٽرگر ان پٽ: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
- گرائونڊنگ: Ensure the unit is properly grounded according to local electrical codes and safety standards.
6. آپريٽنگ هدايتون
- طاقت ڪر، همت ڪر: Once all connections are secure and verified, apply power to the ACM8 unit.
- LED اشارا: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
- Trigger Functionality: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
- Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.
7. سار سنڀال
- باقاعده چڪاس: Periodically inspect all wiring connections to ensure they are secure and free from corrosion or damage.
- فيوز مٽائڻ: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
- صفائي: Keep the unit free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
- ماحولياتي حالتون: Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.
8. مسئلا حل ڪرڻ
- No Power to Any Outputs:
- Verify that the main input power supply is active and correctly connected to the ACM8.
- Check the main fuse (if applicable to your power supply) and ensure it is intact.
- Individual Output Failure (LED off when active):
- Check the specific output fuse for the affected channel. Replace if blown.
- Verify the wiring to the connected device for shorts or disconnections.
- Ensure the trigger signal for that specific output is being received correctly.
- وقتي آپريشن:
- Inspect all terminal connections for looseness.
- حجم لاء چيڪ ڪريوtage fluctuations from the input power supply.
9. وارنٽي ۽ سپورٽ
For detailed warranty information, technical assistance, or to inquire about service, please contact Altronix customer service directly or visit the official Altronix webسائيٽ. وارنٽي جي دعوي لاء توهان جي خريداري جي رسيد رکو.





