ڊانفاس 034L0097

Danfoss KVR15 Pressure Regulator Instruction Manual

ماڊل: 034L0097

1. تعارف

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss KVR15 Pressure Regulator. The KVR15 is designed to maintain a constant evaporating pressure in refrigeration and air conditioning systems. It features a 5/8 inch ODF connection and an access port for pressure measurement.

Please read this manual thoroughly before installing or operating the unit. Keep this manual for future reference.

2. حفاظت جي ڄاڻ

WARNING: Improper installation, operation, or maintenance can result in serious injury or equipment damage.

3. پيڪيج مواد

پڪ ڪريو ته سڀئي جزا موجود آهن ۽ پيڪنگ کولڻ تي نقصان کان بچيل آهن:

Danfoss KVR15 Pressure Regulator with 5/8 inch ODF connections and an access port

Image: Danfoss KVR15 Pressure Regulator. This image shows the compact design of the regulator, highlighting its 5/8 inch ODF connections on both ends and a small access port located on the side for pressure monitoring.

4. سيٽ اپ ۽ تنصيب

Follow these steps for proper installation of the KVR15 Pressure Regulator:

  1. سسٽم جي تياري: Ensure the refrigeration system is depressurized and isolated before beginning installation.
  2. جڳھ: Install the regulator in the suction line, upstream of the compressor, and preferably in a horizontal pipe run. Ensure there is sufficient space for service and adjustment.
  3. ڪنيڪشن: The KVR15 features 5/8 inch ODF (Outside Diameter Flare) connections. Use appropriate brazing techniques for copper tubing. Ensure the regulator is clean and free of debris before brazing. Protect the valve body from excessive heat during brazing by wrapping it with a wet cloth or using a heat sink compound.
  4. وهڪري جي هدايت: Observe the arrow on the regulator body, which indicates the correct flow direction. Install the regulator so that the refrigerant flows in the direction of the arrow.
  5. رسائي پورٽ: The access port allows for pressure measurement. Ensure the cap is securely tightened after use to prevent leaks.
  6. ليڪ ٽيسٽ: After installation, perform a thorough leak test on all connections using an appropriate leak detection method.
  7. نڪرڻ: Evacuate the system to the required vacuum level before charging with refrigerant.

تجويز ڪيل اوزار: Brazing torch, nitrogen for purging, leak detector, vacuum pump, manifold gauge set, pipe cutters, deburring tool, wet rags or heat sink compound.

5. آپريٽنگ هدايتون

The KVR15 regulator is designed to maintain a constant evaporating pressure. Adjustment is typically performed during system commissioning.

  1. شروعاتي سيٽنگ: The regulator is factory set to a nominal pressure. For specific system requirements, adjustment may be necessary.
  2. دٻاء کي ترتيب ڏيڻ:
    • Remove the protective cap from the adjustment spindle.
    • Turn the adjustment spindle clockwise to increase the evaporating pressure.
    • Turn the adjustment spindle counter-clockwise to decrease the evaporating pressure.
    • Use a pressure gauge connected to the access port or elsewhere in the suction line to monitor the pressure while adjusting.
    • Make small adjustments and allow the system to stabilize before making further changes.
    • Once the desired pressure is achieved, replace and tighten the protective cap to secure the setting and prevent leaks.
  3. Access Port Usage: The access port allows for temporary connection of a pressure gauge to verify the regulated pressure. Always ensure the port cap is securely tightened when not in use.

6. سار سنڀال

The Danfoss KVR15 Pressure Regulator is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

نوٽ: Internal components of the KVR15 are not user-serviceable. If the regulator malfunctions, it should be replaced by a qualified technician.

7. مسئلا حل ڪرڻ

This section provides solutions to common issues that may arise with the KVR15 Pressure Regulator.

مسئلوممڪن سببحل
Regulated pressure is too high/low.Incorrect adjustment setting.Adjust the regulator setting as described in the "Operating Instructions" section.
Pressure fluctuates significantly.System instability; debris in regulator; incorrect sizing.Check for system issues (e.g., TXV operation). If debris is suspected, the regulator may need replacement. Verify regulator sizing for the application.
Refrigerant leak at connections.Improper brazing; loose access port cap.Re-braze connections if necessary. Ensure access port cap is securely tightened.
No pressure regulation.Internal failure; completely clogged.The regulator may need to be replaced. Consult a qualified technician.

If troubleshooting steps do not resolve the issue, contact a qualified HVAC/R technician or Danfoss technical support.

8. وضاحتون

خاصيتتفصيل
برانڊڊينفوس
ماڊل نمبر034L0097
قسمEvaporating Pressure Regulator (KVR15)
ڪنيڪشن سائيز5/8 inch ODF (Outside Diameter Flare)
ماپ جو نظامانچ
خاصيتونرسائي پورٽ
ٺاهيندڙڊينفوس
ASINB0085POK2G
تاريخ پهرين دستيابڊسمبر 27، 2017

9. وارنٽي ڄاڻ

Danfoss products are manufactured to high-quality standards. This product is covered by Danfoss's standard manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage details, can be found on the official Danfoss website or by contacting Danfoss customer service. Please retain your proof of purchase for warranty claims.

نوٽ: The warranty may be voided by improper installation, unauthorized modifications, or use outside of specified operating conditions.

10. ڪسٽمر سپورٽ

For technical assistance, spare parts, or further information regarding the Danfoss KVR15 Pressure Regulator, please visit the official Danfoss webسائيٽ تي وڃو يا انهن جي ڪسٽمر سپورٽ ڊپارٽمينٽ سان رابطو ڪريو.

ڊين فاس آفيشل Webسائيٽ: www.danfoss.com

When contacting support, please have your product model number (034L0097) and serial number (if applicable) ready.