This manual provides instructions for the safe and effective operation of your ATD Tools 70001 Laser Infrared Thermometer. This device is designed for non-contact temperature measurement, offering a wide measurement range and an automatic power-off feature for convenience.
حفاظت جي ڄاڻ
مھرباني ڪري ھن پراڊڪٽ کي استعمال ڪرڻ کان پھريان سڀ حفاظتي ڊيڄاريندڙ ۽ ھدايتون احتياط سان پڙھو. انھن ھدايتن تي عمل ڪرڻ ۾ ناڪامي جي نتيجي ۾ ڊوائيس کي زخم يا نقصان ٿي سگھي ٿو.
ليزر حفاظت جي خبرداري
CAUTION: LASER RADIATION. DO NOT STARE INTO BEAM.
- ليزر کي سڌو سنئون اکين يا عکاس سطحن ڏانهن اشارو نه ڪريو.
- ليزر شعاع جي سڌي طرح اکين جي نمائش کان پاسو ڪريو.
- Use caution when operating the laser thermometer in areas where others may be present.
عام حفاظتي احتياط
- Do not immerse the device in water, despite its waterproof feature, to prevent damage to internal components.
- ڊوائيس کي مضبوط برقي مقناطيسي شعبن کان پري رکو.
- Do not attempt to disassemble or modify the thermometer.
- ڊوائيس کي سڪي، ٿڌي جاء تي ذخيرو ڪريو جڏهن استعمال ۾ نه هجي.
پيداوار جا اجزاء
The ATD Tools 70001 Laser Infrared Thermometer includes the following:
- ATD Tools 70001 Laser Infrared Thermometer unit
- هڪ 9V بيٽري
- ھدايت وارو دستور

سيٽ اپ ڪريو
بيٽري لڳائڻ
- Locate the battery compartment cover, typically on the handle.
- ڪپڙا کوليو.
- شامل ڪيل 9V بيٽري داخل ڪريو، صحيح پولارٽي (+/-) کي يقيني بڻائي.
- بيٽري جي ڪمري واري ڍڪ کي محفوظ طور تي بند ڪريو.
نوٽ: The device requires one 9V battery for operation. Ensure the battery is properly installed before use.
آپريٽنگ هدايتون
ماپ وٺڻ
- Point the thermometer at the target object.
- Press and hold the trigger to activate the laser and begin measurement. The laser dot indicates the center of the measurement area.
- درجه حرارت پڙهڻ LCD اسڪرين تي ڏيکاري ويندي.
- ڊسپلي تي ريڊنگ رکڻ لاءِ ٽرگر ڇڏايو.
اسپاٽ جي نسبت کان مفاصلو (D:S)
The ATD Tools 70001 has a Distance to Spot ratio of 12:1. This means that at a distance of 12 inches from the target, the measurement area (spot) will be 1 inch in diameter. To ensure accurate readings, position the thermometer at an appropriate distance from the target so that the measurement spot is entirely within the object being measured.

خودڪار پاور بند
The thermometer features an automatic power-off function to conserve battery life. The device will power off after a period of inactivity (approximately 10-15 seconds after releasinجي ٽرگر).
سار سنڀال
صفائي
To clean the thermometer, wipe the exterior with a clean, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lens and sensor are kept clean for accurate readings.
بيٽري مٽائڻ
When the battery indicator appears on the display, replace the 9V battery following the installation steps outlined in the "Setup" section.
مشڪلاتون
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| ڊوائيس تي طاقت نه آهي | مئل يا غلط نصب ٿيل بيٽري | Replace the 9V battery or ensure it is installed with correct polarity. |
| غلط پڙھڻ |
|
|
| ليزر نظر نه ٿو اچي | Laser function disabled or malfunction | Ensure the laser is enabled (if applicable, check device specific controls). If problem persists, contact support. |
وضاحتون
- ماڊل: ATD Tools 70001
- ماپ جي حد: -76°F کان 1022°F (-60°C کان 550°C)
- ڊسپلي قرارداد: LCD ڊجيٽل
- Distance to Spot Ratio (D:S): 12:1
- جواب ڏيڻ جو وقت: 1 سيڪنڊ
- طاقت جو ذريعو: 1 x 9V بيٽري (شامل)
- خودڪار پاور بند: Yes (approx. 10-15 seconds)
- خاص خاصيتون: پنروڪ
- پيداوار جي ماپ: 4.43 x 1.63 x 5.82 انچ
- شيء جو وزن: 8 اونس
- اصليت جو ملڪ: چين
- UPC: 663126700010
وارنٽي ۽ سپورٽ
For warranty information or technical support, please refer to the documentation included with your purchase or contact ATD Tools customer service. Contact details are typically available on the manufacturer's official webسائيٽ.
ATD Tools Official Webسائيٽ: www.atdtools.com