1. Introduction and General Safety
The 3M Particulate Respirator 8576 P95 is designed to provide respiratory protection against certain oil and non-oil based particles, and nuisance levels of acid gases. This product is intended for industrial and occupational use only and is not for consumer sale or use.
خبردار:
- These respirators help protect against certain airborne contaminants. Before use, the wearer must read and understand the User Instructions provided as part of the product packaging.
- A written respiratory protection program must be implemented meeting all the requirements of OSHA 1910.132 and 1910.134, and all other applicable health and safety standards.
- This includes training, fit testing, and medical evaluation.
- Misuse of personal protective equipment may result in injury, sickness, or death.
- For correct product selection and use, individuals should consult their on-site safety professional or industrial hygienist.
2. پراڊڪٽ ختمview
The 3M Particulate Respirator 8576 P95 is a NIOSH-approved respirator offering at least 95% filtration efficiency against both oil and non-oil based particles. It features a carbon filter material for relief against nuisance levels of acid gases.

Image 2.1: A pack of ten 3M Particulate Respirator 8576 P95 masks, highlighting the P95 rating and NIOSH approval.
اهم خاصيتون شامل آهن:
- NIOSH P95 Approval: Provides 95% filtration efficiency against certain oil and non-oil based particles.
- 3M ٿڌي وهڪري جي اخراج جو والو: Designed to reduce heat and humidity buildup inside the respirator, enhancing comfort during extended wear.
- M-Noseclip: Adjustable to help achieve a secure seal and reduce eyewear fogging.
- ڪاربان فلٽر: Offers relief from nuisance levels of acid gases.
- Soft Inner Material and Braided Headbands: Contribute to wearer comfort and secure fit.

Image 2.2: Diagram showing the internal workings of the 3M Cool Flow Valve, which releases exhaled air.
Video 2.1: This video demonstrates the patented 3M Cool Flow Valve, explaining how it helps reduce heat and moisture buildup inside the respirator for increased comfort.
Recommended applications include grinding, sanding, sweeping, bagging, and other dusty/oily operations, as well as environments with nuisance levels of acid gases such as sulfur dioxide, hydrogen fluoride, and/or chlorine.
وڊيو 2.2: هڪ 360 درجا view of the 3M 8576 Particulate Respirator, showcasinان جي ڊيزائن ۽ خاصيتن کي سڀني زاوين کان ڏسو.
3. Setup: Fitting Instructions
Proper fit is crucial for the respirator to provide its intended protection. Follow these steps to ensure a secure seal:
- پوزيشن: پنهنجي هٿ ۾ ريسپائريٽر کي پنهنجي آڱرين تي نوز پيس سان جهليو، هيڊ بينڊ کي پنهنجي هٿ هيٺ آزاديءَ سان لٽڪڻ ڏيو.
- لڳائڻ: Place the respirator over your nose and mouth.
- Headbands: Pull the top headband over your head and position it high on the crown of your head. Pull the bottom headband over your head and position it around your neck, below your ears.
- نڪ جي ڪلپ جي ترتيب: Use both hands to mold the M-noseclip to the shape of your nose. Pinching with one hand may result in a less effective seal.
- مهر چيڪ: Perform a user seal check according to the instructions on the product packaging. If you detect any leakage, readjust the respirator and repeat the seal check.

Image 3.1: Visual guide demonstrating the four key steps for correctly fitting the 3M Particulate Respirator.
Video 3.1: This video emphasizes the importance of proper respirator fit and demonstrates how to achieve a secure seal for effective protection.
4. آپريٽنگ هدايتون
Once properly fitted, the respirator functions by filtering airborne particles and providing relief from nuisance levels of acid gases as you breathe. The Cool Flow Valve opens during exhalation to release warm, moist air, and closes during inhalation to maintain filtration.
- Wear the respirator for the duration required by your task or until breathing becomes difficult.
- Do not remove the respirator in contaminated areas.
- If the respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area immediately and replace the respirator.
5. مينٽيننس ۽ اسٽوريج
The 3M Particulate Respirator 8576 P95 is a disposable respirator. It is not designed to be cleaned or reused. Discard the respirator after each use, or if it becomes damaged, soiled, or breathing becomes difficult.
Store unused respirators in their original packaging in a clean, dry environment, away from contaminants, extreme temperatures, and direct sunlight.
6. مسئلا حل ڪرڻ
If you experience any issues with your 3M Particulate Respirator 8576 P95, consider the following:
- غريب مهر: If you feel air leaking around the edges of the respirator during a seal check, readjust the headbands and reshape the M-noseclip. Ensure the respirator is positioned correctly on your face.
- تڪليف: If the respirator feels uncomfortable, ensure the headbands are not too tight or twisted. The soft inner material and cup shape are designed for comfort, but individual fit may vary.
- Breathing Difficulty: If breathing becomes difficult, this indicates the filter media may be clogged. Immediately leave the contaminated area and replace the respirator with a new one.
- Eyewear Fogging: Ensure the M-noseclip is properly molded to your nose to create a tight seal, which helps direct exhaled air away from eyewear.
7. وضاحتون
| خاصيت | تفصيل |
|---|---|
| ماڊل نمبر | 8576 |
| فلٽر ڪلاس | P95 (NIOSH Approved) |
| فلٽريشن ڪارڪردگي | At least 95% against oil and non-oil based particles |
| Acid Gas Relief | Yes, for nuisance levels |
| Exhalation والو | 3M Cool Flow Valve |
| Noseclip | Adjustable M-Noseclip |
| هيڊ بينڊ | لٽيل |
| مواد جي خصوصيت | Biodegradable Warning |
| رنگ | اڇو |
| پيداوار جي ماپ | 5 x 6.2 x 8.5 انچ |
| شيءِ جو وزن | 1.6 اونس |
| شين جو تعداد | 10 (في پيڪ) |
8. سپورٽ
For additional product information or technical assistance, please contact 3M PSD Technical Service:
- فون (آمريڪا): 1-800-243-4630
- Webسائيٽ: گهمڻ www.3M.com
Please have your product model number (8576) available when contacting support.