1. تعارف
This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of the Legrand 412544 CX3 Contactor. Please read this manual thoroughly before installation and use, and retain it for future reference. This device is designed for controlling electrical circuits, typically for switching loads in residential, commercial, or industrial applications.
2. حفاظت جي ڄاڻ
خبردار: Electrical installation and maintenance should only be performed by qualified and authorized personnel. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Always disconnect power at the main circuit breaker or fuse box before installing, servicing, or removing the contactor.
- پڪ ڪريو ته سڀئي وائرنگ مقامي ۽ قومي برقي ڪوڊن جي تعميل ڪن ٿيون.
- جلد جي تصديق ڪريوtage and current ratings of the contactor are suitable for the intended application.
- جيڪڏهن ڪانٽيڪٽر خراب نظر اچي ته ان کي نه هلايو.
- انسٽاليشن ۽ سار سنڀال دوران مناسب ذاتي حفاظتي سامان (PPE) استعمال ڪريو.
3. پراڊڪٽ ختمview
The Legrand 412544 CX3 Contactor is a modular device designed for DIN rail mounting. It features two Normally Open (NO) contacts and is rated for 25 Amperes at 230-250 Volts AC. The contactor includes a manual override function for testing or temporary operation.

شڪل 1: Legrand 412544 CX3 Contactor. This image displays the Legrand 412544 CX3 Contactor. Visible features include the 25A rating, 250V operating voltage, and the Legrand brand logo. The front panel shows the manual override lever with 'AUTO' and 'O' (Off) positions, and screw terminals labeled A1, A2 for the coil, and 1, 2, 3, 4 for the main contacts.
اهم خاصيتون:
- رابطي جو قسم: 2 Normally Open (NO) contacts
- Rated Current (I max): 25 اي
- آپريٽنگ جلدtage (Ue): 230-250 V اي سي
- ڪنٽرول Voltage: 230 V AC
- ماڊلز جو تعداد: 1 (for DIN rail mounting)
- آپريٽنگ موڊ: چالو بند
- ٽرمينل جو قسم: اسڪرو ٽرمينل
- ايڪٽيوٽر جو قسم: پسٽن
- مواد جو رابطو لوهي اسٽيل
4. سيٽ اپ ۽ تنصيب
Before proceeding, ensure power is disconnected as per Section 2, "Safety Information."
4.1 چڙهڻ
- Locate an appropriate position on a standard DIN rail within an electrical enclosure.
- Clip the contactor onto the DIN rail. Ensure it is securely fastened.
4.2 وائرنگ
The contactor features screw terminals for secure electrical connections. Refer to the markings on the device for correct wiring.
- Coil Terminals (Control Circuit): ڪنٽرول حجم سان ڳنڍيوtage (230V AC) to terminals A1 ۽ A2. A1 is typically for the phase/live wire, and A2 for the neutral.
- Main Contacts (Power Circuit):
- Connect the incoming power supply to terminals 1 ۽ 3.
- Connect the load to terminals 2 ۽ 4.
- پڪ ڪريو ته سڀئي ڪنيڪشن تنگ ۽ محفوظ آهن ته جيئن رابطن کي ڍلو ٿيڻ ۽ گرم ٿيڻ کان روڪيو وڃي.
- Double-check all wiring against the electrical diagram of your installation before restoring power.
5. آپريٽنگ هدايتون
Once installed and wired correctly, the contactor operates by applying voltage to its control coil (A1-A2).
- خودڪار آپريشن: جڏهن ڪنٽرول voltage (230V AC) is applied to terminals A1 and A2, the contactor coil energizes, closing the main contacts (1-2 and 3-4). This allows power to flow to the connected load. When the control voltage is removed, the coil de-energizes, and the contacts open, disconnecting the load.
- دستي اوور رائڊ: The contactor is equipped with a manual override lever on the front panel.
- Move the lever to the 'AUTO' position for normal automatic operation via the control circuit.
- Move the lever to the 'O' (Off) position to manually open the contacts, regardless of the control circuit status. This can be used for maintenance or to ensure the load remains off.
- Some models may also feature a manual 'ON' position for continuous closure of contacts, independent of the control circuit. Refer to the specific markings on your device.
6. سار سنڀال
The Legrand 412544 CX3 Contactor is designed for reliable, long-term operation with minimal maintenance. However, periodic checks are recommended.
- بصري چڪاس: جسماني نقصان، رنگ بدلجڻ، يا ڍڪيل ڪنيڪشن جي ڪنهن به نشاني لاءِ وقتي طور تي ڪانٽيڪٽر جو معائنو ڪريو.
- ٽرمينل سختي: Ensure all screw terminals remain tight. Loose connections can lead to overheating and potential failure.
- صفائي: If necessary, gently clean the exterior of the contactor with a dry, lint-free cloth. Do not use liquids or abrasive cleaners.
- ڪارڪردگي چيڪ: With power disconnected from the load circuit, test the manual override function to ensure smooth operation.
اهم: ڪنهن به سار سنڀال ڪرڻ کان اڳ هميشه بجلي بند ڪريو.
7. مسئلا حل ڪرڻ
If the contactor is not functioning as expected, consider the following common issues and solutions:
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| Contactor does not energize (contacts do not close) |
|
|
| Contactor energizes but load does not receive power |
|
|
| Contactor makes humming noise |
|
|
If problems persist after attempting these solutions, contact a qualified electrician or Legrand customer support.
8. وضاحتون
| برانڊ | Legrand |
| ماڊل نمبر | 412544 |
| Rated Current (I max) | 25 اي |
| آپريٽنگ جلدtage (Ue) | 230-250 V اي سي |
| ڪنٽرول Voltage | 230 V AC |
| رابطي جو قسم | 2 عام طور تي کليل (NO) |
| ماڊلز جو تعداد | 1 |
| آپريٽنگ موڊ | چالو بند |
| ٽرمينل جو قسم | اسڪرو ٽرمينل |
| سرڪٽ جو قسم | 2-رستو |
| عمل ڪندڙ جو قسم | پسٽن |
| رابطي جو مواد | لوهي اسٽيل |
| چڙهڻ | ڊين ريل |
9. وارنٽي ۽ سپورٽ
For information regarding product warranty, technical support, or service, please refer to the official Legrand website or contact your local Legrand distributor. Keep your purchase receipt as proof of purchase.