1. تعارف
The GIMA OXY 6 Finger Pulse Oximeter is a portable device designed for non-invasive spot-checking of arterial oxygen saturation (SpO2) and pulse rate. It is suitable for use in medical and hospital environments, as well as for personal use under medical guidance. This manual provides essential information for the safe and effective operation of the device.
2. حفاظت جي ڄاڻ
Please read all safety warnings and precautions before using the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is intended for spot-checking and not for continuous monitoring.
- ايم آر آئي يا سي ٽي ماحول ۾ آڪسيميٽر استعمال نه ڪريو.
- ڊوائيس کي پاڻي ۽ نمي کان پري رکو.
- Consult a medical professional for interpretation of readings. This device is not a substitute for professional medical advice.
- Ensure the finger is clean and free of nail polish or artificial nails, as these can affect accuracy.
- Avoid excessive movement during measurement to ensure stable readings.
3. پراڊڪٽ ختمview
The GIMA OXY 6 features a high-resolution OLED color display showing SpO2, pulse rate, pulse bar graph, perfusion index (PI), and battery level. It is designed for ease of use with a compact form factor.

شڪل 1: سامهون view of the GIMA OXY 6 Pulse Oximeter, displaying SpO2 and pulse rate values on its screen.
3.1. پيڪيج مواد

شڪل 2: The package includes the GIMA OXY 6 Pulse Oximeter, a plastic case, AAA batteries, and a lanyard.
- GIMA OXY 6 Pulse Oximeter
- 2 x AAA بيٽريون
- پلاسٽڪ کڻڻ وارو ڪيس
- لانڍي
- ھدايت وارو دستور

شڪل 3: The GIMA OXY 6 Pulse Oximeter attached to a lanyard, demonstrating its portability and ease of carrying.
4. سيٽ اپ
4.1. بيٽري لڳائڻ
- ڊوائيس جي پوئين پاسي واقع بيٽري ڪمپارٽمينٽ ڪَوَر کوليو.
- ڪمري اندر پولارٽي اشارن (+/-) جي مطابق ٻه AAA بيٽريون داخل ڪريو.
- بيٽري جي ڪمري واري ڍڪ کي محفوظ طور تي بند ڪريو.

شڪل 4: Open battery compartment showing placement for two AAA batteries.
5. آپريٽنگ هدايتون
5.1. ماپ کڻڻ
- پڪ ڪريو ته ڊوائيس ۾ تازيون بيٽريون نصب ٿيل آهن.
- cl کوليوamp آڪسيميٽر جو.
- Insert one finger (preferably the index, middle, or ring finger) into the rubber opening of the oximeter, ensuring the finger is fully inserted and resting on the sensor. The recommended finger thickness for this model is 1-22 mm.
- cl جاري ڪريوamp. ڊوائيس خودڪار طريقي سان آن ٿيندو ۽ ماپ شروع ڪندو.
- Keep your hand still during the measurement. Avoid bending your finger or making hand movements.
- Readings for SpO2, Pulse Rate, and Perfusion Index (PI) will appear on the display within a few seconds.

شڪل 5: The GIMA OXY 6 Pulse Oximeter correctly placed on a finger for measurement.
5.2. ڊسپلي کي سمجهڻ
- SpO2: Peripheral Oxygen Saturation, displayed as a percentage.
- پي آر: Pulse Rate, displayed in beats per minute (bpm).
- PI: Perfusion Index, a numerical value indicating the strength of the pulse signal at the sensor site.
- Pulse Bar Graph: Visual representation of pulse strength.
- بيٽري جو اشارو: موجوده بيٽري جي سطح ڏيکاري ٿو.
5.3. خودڪار بجلي بند
The device will automatically power off after approximately 8 seconds of inactivity or when the finger is removed.
5.4. گھٽ وولٽtage الارم
جڏهن ته بيٽري voltage is low, a low voltage alarm will be indicated on the display. Replace the batteries promptly to ensure accurate operation.
5.5. وائيس گائيڊ
The GIMA OXY 6 features an 8-language voice guide (English, French, Italian, Spanish, Greek, Portuguese, Arabic) for enhanced usability. Refer to the full manual for specific instructions on activating and changing voice guide settings.
6. سار سنڀال
6.1. صفائي
- آڪسيميٽر جي مٿاڇري کي نرم ڪپڙي سان صاف ڪريو dampطبي الڪوحل (70٪ ايٿانول يا آئسوپروپانول) سان ملايو ويو.
- ڊوائيس کي پاڻي يا ڪنهن به صفائي واري محلول ۾ نه ٻوڙيو.
- ٻيهر استعمال ڪرڻ کان اڳ پڪ ڪريو ته ڊوائيس مڪمل طور تي سڪي ويو آهي.
6.2. بيٽري مٽائڻ
بيٽرين کي تبديل ڪريو جڏهن گهٽ حجمtage indicator appears. Always use two new AAA alkaline batteries. Dispose of used batteries according to local regulations.
6.3. اسٽوريج
Store the oximeter in its plastic carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
7. مسئلا حل ڪرڻ
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| بجلي ڏيکارڻ بعد ڪوبه ڊسپلي نه | بيٽريون مئل يا غلط نصب ٿيل آهن. | بيٽريون تبديل ڪريو يا انهن کي صحيح طريقي سان ٻيهر انسٽال ڪريو، پولارٽي کي ڏسندي. |
| غلط پڙھڻ | Finger not properly inserted; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm the finger. |
| "فنگر آئوٽ" يا ساڳيو غلطي پيغام | آڱر نه ملي يا غلط طريقي سان رکيل هجي. | Ensure finger is fully inserted and resting on the sensor. |
| ڊوائيس غير متوقع طور تي بند ٿي وئي | Low battery; automatic power-off due to inactivity. | Replace batteries; ensure finger is inserted for measurement. |
8. وضاحتون
| ماڊل نمبر | 34285 (OXY 6) |
| ڊسپلي جو قسم | OLED رنگ ڊسپلي |
| ماپ جا پيرا ميٽر | SpO2, Pulse Rate, Perfusion Index (PI) |
| SpO2 Measurement Range | (Typical range, refer to device for exact range) |
| نبض جي شرح جي ماپ جي حد | (Typical range, refer to device for exact range) |
| درستگي | High precision and repeatability with noise suppression |
| بجلي جي گهرج | 2 x AAA 1.5V الڪلائن بيٽريون |
| بيٽري جي زندگي | Approximately 3 hours of continuous operation with full batteries |
| طول و عرض (L x W x H) | 16 x 5.5 x 10 سينٽي |
| وزن | 200 گرام (بيٽرين سميت) |
| Finger Thickness Range | 1-22 ملي ميٽر |
| وائيس گائيڊ | 8 languages (GB, FR, IT, ES, GR, PT, Arabic) |
9. وارنٽي ۽ سپورٽ
Information regarding specific warranty terms and customer support for the GIMA OXY 6 Pulse Oximeter is not provided in this document. Please refer to the product packaging or contact GIMA customer service for details.