1. تعارف
This manual provides essential information for the proper installation, operation, and maintenance of the RIELLO 3012174 Probe. This probe is a critical component designed specifically for use with RIELLO RS 28/1 and RS 38/1 Gas Burners, ensuring their safe and efficient operation. Please read this manual thoroughly before attempting any installation or service.
2. پراڊڪٽ ختمview
The RIELLO 3012174 Probe is a flame sensing or ignition electrode component integral to the control system of compatible RIELLO gas burners. Its primary function is to detect the presence of a flame or to provide the spark for ignition, thereby ensuring the safe and controlled combustion process. This probe is manufactured to precise specifications to guarantee compatibility and reliable performance with the designated burner models.
Figure 1: The RIELLO 3012174 Probe as supplied in its protective packaging. The image shows a slender metallic rod with a bent end, encased in clear plastic, with a label indicating the part number and manufacturer.
3. سيٽ اپ ۽ تنصيب
حفاظت جي خبرداري:
- Always disconnect power to the gas burner and shut off the gas supply before beginning any installation or service work.
- Installation should only be performed by qualified and certified technicians in accordance with local codes and regulations.
- مناسب گرائونڊنگ ۽ برقي ڪنيڪشن کي يقيني بڻايو وڃي.
تنصيب جا مرحلا:
- تياري: Ensure the burner is cool and all power and gas supplies are safely disconnected.
- رسائي: Carefully open the burner housing or access panel to locate the existing probe or the designated mounting point for the new probe.
- هٽائڻ (جيڪڏهن تبديل ڪيو وڃي): Disconnect any wiring attached to the old probe. Carefully unmount and remove the old probe, noting its orientation and position.
- Installation of New Probe: Insert the new RIELLO 3012174 Probe into its designated slot or mounting bracket. Ensure it is correctly oriented and securely fastened.
- وائرنگ: Reconnect any necessary wiring to the new probe, ensuring connections are tight and correct according to the burner's wiring diagram.
- ٻيهر گڏ ڪرڻ: Close and secure the burner housing or access panel.
- تصديق: Before restoring power and gas, double-check all connections and ensure no tools or debris are left inside the burner.
4. آپريٽنگ هدايتون
The RIELLO 3012174 Probe operates automatically as part of the gas burner's control sequence. Once installed, its function is integrated into the burner's ignition and flame supervision system. No direct user interaction is required for its operation.
- Upon a call for heat, the burner control unit initiates the ignition sequence.
- If the probe functions as an ignition electrode, it will generate a spark to ignite the gas.
- If the probe functions as a flame sensor, it will detect the presence of the flame. A successful flame detection signals the control unit to continue burner operation.
- In the absence of a detected flame within a specified safety time, the control unit will initiate a lockout, preventing uncombusted gas from accumulating.
5. سار سنڀال
Regular inspection and maintenance of the RIELLO 3012174 Probe are crucial for ensuring the long-term reliability and safety of your gas burner. Maintenance should be performed by a qualified technician.
- سالياني چڪاس: It is recommended to inspect the probe annually as part of routine burner maintenance.
- بصري چڪاس: Look for signs of wear, cracking, carbon buildup, or corrosion on the ceramic insulator and the metallic tip.
- صفائي: If carbon deposits are present, carefully clean the probe's tip and ceramic insulator using a fine abrasive pad or brush. Avoid damaging the ceramic.
- Gap Measurement (if applicable): For ignition electrodes, verify the spark gap according to the burner manufacturer's specifications.
- متبادل: Replace the probe if any damage is observed, if it shows excessive wear, or if it fails to perform its function reliably during burner operation.
6. مسئلا حل ڪرڻ
Issues related to the RIELLO 3012174 Probe often manifest as burner lockout or intermittent operation. Always ensure power and gas supplies are stable before troubleshooting.
| علامتي | ممڪن سبب | حل |
|---|---|---|
| Burner locks out after ignition attempt (no flame detected) |
|
|
| Intermittent burner operation or unexpected shutdowns |
|
|
جيڪڏهن مسئلا حل ڪرڻ جا قدم مسئلو حل نه ڪن، ته هڪ قابل سروس ٽيڪنيشن سان رابطو ڪريو.
7. وضاحتون
- حصو نمبر: 3012174
- ٺاهيندڙ: ريلو
- مطابقت: RIELLO RS 28/1 Gas Burners, RIELLO RS 38/1 Gas Burners
- فنڪشن: Flame sensing or ignition electrode (specific function depends on burner model and application)
- مواد: High-temperature resistant metallic alloy and ceramic insulator
8. سرڪاري پراڊڪٽ وڊيوز