1. تعارف
This manual provides essential information for the safe and effective use of the Testo 750-2 Voltage Tester. Please read these instructions thoroughly before operating the device. Proper use ensures accurate measurements and user safety.
The Testo 750-2 is a robust voltage tester designed for electrical professionals. It features a clear LED display for voltage indication, continuity testing, phase rotation detection, and a built-in flashlight for use in dimly lit environments. It also includes GFCI trip functionality.
2. حفاظت جي ڄاڻ
WARNING: Electrical shock hazard. Failure to follow these instructions may result in serious injury or death.
- Always verify the tester's functionality on a known live source before and after use.
- جيڪڏهن ٽيسٽر خراب نظر اچي يا صحيح طريقي سان ڪم نه ڪري رهيو هجي ته ان کي استعمال نه ڪريو.
- Adhere to all local and national safety regulations for electrical work.
- مناسب ذاتي حفاظتي سامان (پي پي اي) پائڻ، جهڙوڪ موصل دستانا ۽ حفاظتي چشما.
- وڌ ۾ وڌ حجم کان وڌيڪ نه ڪريوtagڊوائيس لاءِ بيان ڪيل اي ريٽنگون.
- بجلي جي ماپ ڪرڻ وقت اڪيلو ڪم ڪرڻ کان پاسو ڪريو.
- استعمال دوران ٽيسٽ پروبس تي آڱرين کي فنگر گارڊز جي پويان رکو.
3. پيڪيج مواد
Ensure all items are present and undamaged upon unpacking:
- Testo 750-2 Voltagاي جاچ ڪندڙ
- 2 x AAA بيٽريون (اڳ ۾ نصب ٿيل يا الڳ الڳ شامل)
- استعمال ڪندڙ جو دستياب (ھي دستاويز)
4. پراڊڪٽ ختمview
The Testo 750-2 Voltage Tester consists of two main units connected by a flexible cable. Each unit houses a test probe and controls.

شڪل 1: سامهون view of the Testo 750-2 Voltage Tester. Shows the two main units, test probes (L1, L2), and the LED display indicating voltage levels (12V to 690V AC/DC), continuity (Rx), and phase rotation (L/R).

شڪل 2: زاويه view of the Testo 750-2 Voltage Tester, highlighting its ergonomic design and the integrated flashlight button on the left unit.

شڪل 3: ريڙهه view of the Testo 750-2 Voltage Tester, showing safety markings and product information.

شڪل 4: بند ڪرڻ view of the Testo 750-2 display and controls, showing the voltage indicator LEDs, continuity indicator, phase rotation indicators (L/R), and the flashlight button.
اهم اجزاء:
- Test Probes (L1, L2): For making contact with electrical circuits.
- ايل ايل ڊسپلي: اشارو voltage levels (AC/DC), continuity, and phase rotation.
- ٽارچ بٽڻ: بلٽ ان ٽارچ کي چالو ڪري ٿو.
- GFCI ٽيسٽ بٽڻ: Initiates a GFCI trip test.
- بيٽري جو خانو: Located on the rear of one unit.
5. سيٽ اپ
5.1. بيٽري لڳائڻ
The Testo 750-2 requires 2 AAA batteries for operation. These are typically included.
- Locate the battery compartment cover on the rear of the tester.
- Use a suitable tool (e.g., a small screwdriver) to open the compartment.
- Insert 2 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- بيٽري ٽوڪريءَ کي compڪڻ سان محفوظ سان بند ڪريو.
The device will perform a self-test upon battery installation or when first used, indicated by all LEDs briefly illuminating.
6. آپريٽنگ هدايتون
6.1. جلدtagاي ٽيسٽنگ (اي سي/ڊي سي)
حجم کي ماپڻ لاءtage:
- Ensure the tester is clean and undamaged.
- Connect the L1 and L2 test probes to the points where voltage کي ماپيو وڃي.
- The LED display will illuminate to indicate the detected voltage level (e.g., 12V, 24V, 50V, 120V, 230V, 400V, 690V).
- DC Voltage, the polarity will also be indicated (+/-).
- An audible signal will sound when voltage جو پتو لڳايو ويو آهي.
Note: The Testo 750-2 is designed to provide a clear indication of voltage presence even with discharged batteries, ensuring safety.
6.2. لڳاتار جاچ
To test for continuity (low resistance):
- Ensure the circuit or component is de-energized before testing for continuity.
- Connect the L1 and L2 test probes across the circuit or component.
- If continuity is detected (resistance below a certain threshold), the "Rx" LED will illuminate, and an audible signal will sound.
6.3. Phase Rotation Testing
To determine phase rotation in three-phase systems:
- Connect the L1 probe to the first phase (e.g., L1).
- Connect the L2 probe to the second phase (e.g., L2).
- The "L" or "R" LED will illuminate to indicate the direction of the rotating magnetic field (left or right).
- For a complete three-phase test, connect the L1 probe to L1, L2 probe to L2, then L1 probe to L2, L2 probe to L3, and finally L1 probe to L3, L2 probe to L1, observing the sequence.
6.4. GFCI Trip Test
To test Ground Fault Circuit Interrupter (GFCI) functionality:
- Connect the L1 and L2 test probes to the live and ground terminals of the GFCI-protected outlet or circuit.
- Press and hold the GFCI test button on the tester.
- The GFCI device should trip, interrupting power to the outlet/circuit.
- Release the button and reset the GFCI device.
CAUTION: This test will temporarily cut power to the circuit. Ensure no critical equipment is connected or that appropriate precautions are taken.
6.5. بلٽ ان ٽارچ
To activate the flashlight, press the flashlight button located on one of the tester units. Press again to turn it off. This feature is useful for illuminating dark work areas.
7. سار سنڀال
7.1. صفائي
Clean the tester regularly with a damp ڪپڙو. گھڙڻ وارا صاف ڪندڙ يا محلول استعمال نه ڪريو. پڪ ڪريو ته ڊوائيس اسٽوريج يا ايندڙ استعمال کان اڳ سڪي وڃي.
7.2. بيٽري مٽائڻ
When the battery low indicator appears (if applicable) or the device's performance degrades, replace the batteries as described in Section 5.1. Always use new AAA batteries of the same type.
7.3. اسٽوريج
Store the tester in a dry, clean environment, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
8. مسئلا حل ڪرڻ
- No Indication / Device Not Turning On:
- بيٽري جي انسٽاليشن ۽ پولارٽي چيڪ ڪريو.
- بيٽرين کي نئين سان تبديل ڪريو.
- Ensure probes are making good contact with the test points.
- متضاد پڙهڻ:
- Verify the tester on a known live source.
- Check for damaged test leads or probes.
- Ensure proper contact with the circuit.
- GFCI Test Not Tripping:
- Ensure the GFCI outlet/circuit is properly wired and functional.
- Confirm the tester is connected correctly (live to ground).
- If the GFCI still does not trip, the GFCI device itself may be faulty and requires inspection by a qualified electrician.
If problems persist, contact Testo customer support.
9. وضاحتون
| خاصيت | تفصيل |
|---|---|
| ماڊل نمبر | 0590 7502 |
| جلدtage حد | 12V to 690V AC/DC |
| تسلسل ٽيسٽ | Yes (audible and visual) |
| مرحلو گردش ٽيسٽ | Yes (L/R indication) |
| GFCI Trip Function | ها |
| ٽارچ | تعمير ٿيل |
| طاقت جو ذريعو | 2 x AAA بيٽريون (شامل) |
| پيداوار جي ماپ (L x W x H) | 10.63 x 2.56 x 1.38 انچ |
| شيءِ جو وزن | 9.17 آونس (260 گرام) |
| ٺاهيندڙ | Testo, Inc. |
| اصل جو ملڪ | آمريڪا |
10. وارنٽي ڄاڻ
Testo, Inc. products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Testo webسائيٽ. وارنٽي دعوائن لاءِ خريداري جو ثبوت رکو.
11. سپورٽ ۽ رابطو
For technical support, service, or further information regarding your Testo 750-2 Voltage Tester, please contact Testo, Inc. directly:
- Webسائيٽ: www.testo.com
- Refer to the official Testo website for regional contact details and support resources.





