FORA Painless Design Adjustable Lancing Device

FORA Painless Design Adjustable Lancing Device User Manual

Model: Painless Design Adjustable Lancing Device

1. تعارف

Thank you for choosing the FORA Painless Design Adjustable Lancing Device. This device is designed to assist in obtaining blood samples for glucose monitoring with enhanced comfort and safety. Please read this manual thoroughly before using the device to ensure proper operation and to understand all safety precautions.

اهم خاصيتون:

2. حفاظت جي ڄاڻ

Always follow basic safety precautions when using this lancing device to reduce the risk of injury or infection.

3. پراڊڪٽ ختمview

Familiarize yourself with the components of your FORA Lancing Device:

Diagram of FORA Lancing Device components: Cap, Depth indicator, Ejector, Release Button.

شڪل 3.1: Components of the FORA Lancing Device. This diagram illustrates the main parts: the protective cap, the depth indicator for setting penetration level, the ejector mechanism for safe lancet removal, and the release button to activate the lancing action.

4. سيٽ اپ

4.1 Inserting a Lancet

  1. Unscrew the cap from the lancing device.
  2. لينسيٽ هولڊر ۾ مضبوطيءَ سان هڪ نئون، جراثيم کان پاڪ لينسيٽ داخل ڪريو.
  3. Twist off the protective cap from the lancet. Retain this cap for safe disposal later.
  4. Replace the lancing device cap by screwing it back on.

4.2 Adjusting Penetration Depth

The lancing device features 6 adjustable depth settings. Rotate the cap to select the desired depth. A higher number indicates a deeper penetration.

Three-step illustration for collecting blood samples: 1. Select desired depth, 2. Pull cocking control back, 3. Lance the finger.

شڪل 4.1: Steps for preparing and using the lancing device. This image demonstrates selecting the penetration depth, cocking the device, and performing a finger prick.

5. آپريٽنگ هدايتون

5.1 Performing a Blood Sample (Fingerstick)

  1. پنهنجا هٿ صابڻ ۽ گرم پاڻي سان چڱيءَ طرح ڌوئو، پوءِ انهن کي مڪمل طور تي سڪيو.
  2. Ensure a new lancet is inserted and the depth setting is appropriate for your skin type (refer to Section 4.2).
  3. Pull the cocking control back until it clicks. The device is now armed.
  4. لانسنگ ڊيوائس کي مضبوطيءَ سان پنھنجي آڱر جي پاسي تي رکو.
  5. Press the release button to activate the lancet.
  6. Gently massage your finger from the base towards the tip to form a blood drop. Do not squeeze excessively.
  7. Apply the blood drop to your glucose meter test strip as instructed by your meter's manual.

5.2 Alternative Site Testing (AST)

The FORA Lancing Device includes a clear alternate site end cap for testing on areas other than the fingertip, such as the forearm or palm. Consult your healthcare professional before performing AST, as results from alternative sites may differ from fingertip results, especially during periods of rapid glucose change.

  1. Remove the standard cap and replace it with the clear AST cap.
  2. Select a suitable depth setting (AST generally requires a deeper setting due to thicker skin).
  3. Pull the cocking control back until it clicks.
  4. Press the clear AST cap firmly against the chosen alternative site (e.g., forearm or palm) and hold for a few seconds to create a vacuum.
  5. رليز بٽڻ کي دايو.
  6. Gently massage the area to form a blood drop.
  7. Apply the blood drop to your glucose meter test strip.

5.3 Safely Disposing of a Used Lancet

Proper disposal of used lancets is crucial to prevent accidental needle sticks and the spread of infection.

Two-step illustration for safely disposing of a used lancet: 1. Safely dispose by pushing the exposed tip into a protective disk, 2. Slide the ejector forward to remove the used lancet.

شڪل 5.1: Steps for safe lancet disposal. This image shows how to cap the lancet and then use the ejector mechanism to remove it from the device.

  1. لانسنگ ڊوائيس ڪيپ کي ختم ڪريو.
  2. Carefully place the protective cap (removed in Section 4.1) back onto the used lancet, ensuring the needle is fully covered. Alternatively, if your lancets come with a protective disk, push the exposed tip into the disk on a hard surface.
  3. Slide the ejector forward to release the capped lancet into an approved sharps container.
  4. لينسنگ ڊيوائس ڪيپ کي تبديل ڪريو.

6. سار سنڀال

6.1 Cleaning the Lancing Device

6.2 اسٽوريج

7. مسئلا حل ڪرڻ

If you encounter issues with your lancing device, refer to the table below for common problems and solutions.

مسئلوممڪن سببحل
Device does not cock or fire.Device not fully cocked; lancet not inserted correctly; device malfunction.Ensure the cocking control is pulled back until it clicks. Re-insert lancet. If problem persists, contact customer support.
ناکافي رت sampلي.Depth setting too shallow; insufficient blood flow; cold hands.Increase depth setting. Warm hands before testing. Gently massage the lanced area.
Pain during lancing.Depth setting too deep; reused lancet; lancing on calloused area.Decrease depth setting. Always use a new lancet. Choose a different lancing site.
Lancet cannot be ejected.Lancet stuck; ejector mechanism obstructed.Ensure the cap is removed. Gently try to slide the ejector. If stuck, carefully remove with tweezers and dispose of safely.

8. وضاحتون

خاصيتتفصيل
ماڊلPainless Design Adjustable Lancing Device
ڊيپٿ سيٽنگون6 ترتيب ڏيڻ واري سطح
Lancet CompatibilityMost standard lancets (28-33 gauge)
طول و عرضتقريبن 6.1 x 3.2 x 1 انچ
وزنتقريبن 1.6 آونس
ٺاهيندڙForaCare Inc.
ASINB01INS8T5I

9. وارنٽي ۽ سپورٽ

For warranty information, technical support, or to purchase accessories, please contact FORA customer service or visit the official FORA webسائيٽ.

You can find more information about FORA products and support at the FORA Store on Amazon.

لاڳاپيل دستاويز - Painless Design Adjustable Lancing Device

اڳيview FORA 6 بلڊ گلوڪوز ٽيسٽ اسٽرپ استعمال ڪندڙ جي معلومات ۽ درستگي ڊيٽا
FORA 6 بلڊ گلوڪوز ٽيسٽ اسٽرپس لاءِ جامع گائيڊ، جنهن ۾ ڊيڄاريندڙ، ارادي استعمال، حدون، هٿ کڻڻ، ٽيسٽنگ طريقا، نتيجن جي تشريح، معيار تي ضابطو، ڪيميائي ساخت، درستگي ڊيٽا، ۽ استعمال ڪندڙ جي ڪارڪردگي جي مطالعي جو احاطو ڪيو ويو آهي. صحت جي سار سنڀار جي ماهرن ۽ خود جاچ لاءِ معلومات شامل آهي.
اڳيview FORA Diamond MINI Blood Glucose Meter User Guide
A concise guide to using the FORA Diamond MINI blood glucose meter for self-testing. Learn how to measure blood glucose levels accurately and safely with step-by-step instructions.
اڳيview FORA Diamond GD50 Blood Glucose Meter: Instruction Guide
This guide provides step-by-step instructions for using the FORA Diamond GD50 blood glucose meter for self-testing. Learn how to prepare the device, test your blood glucose, and dispose of used materials safely.
اڳيview FORA 6 Blood Glucose Test Strips - User Guide and Specifications
This document provides comprehensive information on the FORA 6 Blood Glucose Test Strips, including intended use, limitations, storage, handling, testing procedures, and accuracy results. It is designed for both healthcare professionals and individuals managing diabetes.
اڳيview FORA 6 Connect Blood Glucose Meter User Guide
A concise guide to using the FORA 6 Connect blood glucose meter for self-testing, including setup, operation, and app connectivity.
اڳيview FORA 6 Test Strip Instructions, Specifications, and Accuracy Data
Comprehensive guide for FORA 6 Blood Glucose, Hematocrit, and Hemoglobin Test Strips, covering intended use, warnings, limitations, storage, testing procedures, accuracy results, and reference values.