ASTRALPOOL Peristaltic Pump 12L/H 1 bar (Model 57178) Instruction Manual

1. تعارف

1.1 پيداوار ختمview

The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.

1.2 حفاظتي ڄاڻ

Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.

  • ڪنهن به انسٽاليشن يا سار سنڀال ڪرڻ کان اڳ هميشه بجلي بند ڪريو.
  • Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
  • تصديق ڪريو ته پاور سپلائي voltage matches the pump's requirements (230 Volts AC).
  • Do not operate the pump with damaged cables or connections.
  • ڪيميڪلز کي هٿ ڪرڻ يا سار سنڀال ڪرڻ وقت مناسب ذاتي حفاظتي سامان (PPE) پائڻ.

2. سيٽ اپ ۽ تنصيب

2.1 پمپ تي چڙهڻ

Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.

2.2 برقي ڪنيڪشن

The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.

2.3 Fluid Connections

Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

Astralpool Peristaltic Pump 57178 showing the transparent cover, internal tubing, and connection ports.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.

3. آپريٽنگ هدايتون

3.1 شروعاتي شروعاتي

  1. Ensure all fluid connections are secure and the pump is properly mounted.
  2. Verify that the fluid source is available and the discharge line is correctly routed.
  3. Plug the pump into the power supply.

3.2 Flow Regulation

The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).

4. سار سنڀال

4.1 عام سار سنڀال

  • Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
  • Check all connections for leaks and tighten if required.
  • Keep the pump's exterior clean and free from dust and debris.

4.2 صفائي

To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.

5. مسئلا حل ڪرڻ

مسئلوممڪن سببحل
پمپ شروع نٿو ٿئيبجلي جي فراهمي ناهي
خراب ٿيل پاور ڪيبل
پاور ڪنيڪشن ۽ آئوٽليٽ چيڪ ڪريو
Inspect and replace cable if damaged
نه وهندڙ وهڪرينلڪي بند ٿيل يا بند ٿيل
انٽ فلٽر بند ٿيل
Potentiometer set to 0%
Inspect and clear tubing
انٽ فلٽر کي صاف يا تبديل ڪريو
Adjust potentiometer to desired flow rate
Inconsistent flowقطار ۾ هوا
Worn tubing
سسٽم مان هوا کي ڦوڪيو
Replace peristaltic tubing
Leakage at connectionsلاڳاپا لاڳاپا
Damaged seals/tubing
سڀني رابطن کي مضبوط ڪريو
Inspect and replace seals or tubing

6. ٽيڪنيڪل وضاحتون

تفصيلقدر
برانڊAstralpool
ماڊل نمبر57178
پيداوار جي ماپ (L x W x H)23 x 11 x 13 سينٽي
وزن900 گرام
جلدtage230 وولٽ (AC)
وهڪري جي شرحUp to 12 L/H (continuously adjustable)
وڌ ۾ وڌ دٻاءُ1 بار
اسپيئر پارٽس جي دستيابيمعلومات دستياب ناهي

لاڳاپيل دستاويز - 57178

اڳيview ايسٽرل پول هيلو ڊوزر پي ايڇ ڊوزنگ ماڊيول انسٽاليشن مينوئل
ايسٽرل پول هيلو ڊوزر پي ايڇ ڊوجنگ ماڊيول لاءِ انسٽاليشن مينوئل، حفاظتي هدايتون، سسٽم اوور کي ڍڪينديview، تنصيب، ڪنٽرول، سار سنڀال، ۽ مسئلا حل ڪرڻ.
اڳيview AstralPool QB800 روبوٽڪ پول ڪلينر: استعمال ڪندڙ مينوئل ۽ گائيڊ
هي دستورالعمل AstralPool QB800 روبوٽڪ پول ڪلينر جي انسٽاليشن، آپريشن، سار سنڀال، ۽ خرابي جي حل لاءِ جامع هدايتون مهيا ڪري ٿو.
اڳيview آبي استعمالن لاءِ ASTRALPOOL اسٽينلیس سٹیل جي سار سنڀال جي گائيڊ
آبي ماحول ۾ ASTRALPOOL اسٽينلیس سٹیل جي حصن کي برقرار رکڻ لاءِ ضروري گائيڊ. صفائي، آڪسائيڊشن کي روڪڻ، ۽ ڊگهي عمر کي يقيني بڻائڻ لاءِ بهترين طريقا سکو.
اڳيview ايسٽرل پول ڪلاسڪ پلس ملٽي پورٽ والو: انسٽاليشن، سار سنڀال، ۽ مسئلا حل ڪرڻ جي گائيڊ
ايسٽرل پول ڪلاسڪ پلس ملٽي پورٽ والو (ماڊل 73950-1000) لاءِ تفصيلي گائيڊ. والو آپريشن، قدم بہ قدم انسٽاليشن، ضروري سار سنڀال جا طريقا، مڪمل حصن جي فهرست، ۽ سوئمنگ پول فلٽر سسٽم لاءِ عام خرابين جي حل کي ڍڪي ٿو.
اڳيview ايسٽرل پول هيلو ايڪسپينڊ آٽوميشن ايڪسپينڊ ماڊيول انسٽاليشن مينوئل
هي دستورالعمل AstralPool Halo Xpand آٽوميشن ايڪسپينڊ ماڊل لاءِ انسٽاليشن جون هدايتون مهيا ڪري ٿو، جنهن ۾ سسٽم جي تفصيل شامل آهيview، ماؤنٽنگ، پاور ڪنيڪشن، جوڙو، ترتيب، ڪنٽرول طريقا، ۽ مسئلا حل ڪرڻ.
اڳيview بلوٽوٿ سان ايسٽرل پول وائرون سالٽ ڪلورينيٽر: انسٽاليشن ۽ آپريٽنگ مينوئل
بلوٽوٿ سان ايسٽرل پول وائرون سالٽ ڪلورينيٽر لاءِ جامع انسٽاليشن، آپريشن، ۽ سار سنڀال جي گائيڊ. سيٽ اپ، ٽربل شوٽنگ، ۽ پول ڪيمسٽري مئنيجمينٽ سکو.