This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss EVR 3 Solenoid Valve, model 032F1204. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent potential hazards.
2. پراڊڪٽ ختمview
The Danfoss EVR 3 is a normally closed (NC) solenoid valve designed for various industrial and refrigeration applications. It features 3/8 inch ODF (Outside Diameter Flared) connections, ensuring a secure and leak-tight fit. This valve is engineered for reliability and precise control of fluid flow.

شڪل 2.1: سامهون view of the Danfoss EVR 3 Solenoid Valve with the solenoid coil installed. This image highlights the main body, ODF connections, and the attached coil with its specifications.

شڪل 2.2: ريڙهه view of the Danfoss EVR 3 Solenoid Valve, indicating the flow direction with an arrow and displaying regulatory markings.

شڪل 2.3: The Danfoss EVR 3 Solenoid Valve (032F1204) shown with its original packaging box, displaying product details and "Made in Poland" label.
3. حفاظت جي ڄاڻ
- Always disconnect power before installing, servicing, or removing the solenoid valve.
- Ensure the system pressure is relieved before working on the valve.
- مناسب ذاتي حفاظتي سامان (پي پي اي) پائڻ جهڙوڪ حفاظتي چشما ۽ دستانا.
- تنصيب ۽ سار سنڀال صرف قابل عملدار طرفان ڪئي وڃي.
- Verify that the valve's specifications (pressure, temperature, fluid compatibility) match the application requirements.
- Avoid exposing the valve to excessive mechanical stress or vibration.
4. تنصيب
4.1 قبل از انسٽاليشن چيڪ
- Inspect the valve for any signs of damage during shipping.
- Confirm that the model number (032F1204) and specifications match your order and application.
- Ensure all necessary tools and fittings are available.
4.2 Mounting and Connection
- Mount the valve in a position that allows for easy access for maintenance and inspection. The valve can be installed in any position, but it is recommended to install with the coil upwards to prevent accumulation of debris.
- Ensure the flow direction arrow on the valve body aligns with the system's fluid flow.
- Connect the 3/8 inch ODF pipes to the valve's inlet and outlet ports. Use appropriate flaring tools and techniques to ensure a leak-free connection.
- Tighten connections to the manufacturer's recommended torque specifications to prevent leaks without over-stressing the valve body.
4.3 برقي ڪنيڪشن
- بجلي جي فراهمي کي يقيني بڻائيtage and frequency match the specifications of the solenoid coil.
- Connect the solenoid coil to the appropriate electrical circuit. Follow local electrical codes and safety standards.
- Secure all electrical connections to prevent accidental disconnection or short circuits.
5. آپريشن
The Danfoss EVR 3 (032F1204) is a normally closed (NC) solenoid valve. This means that when the solenoid coil is de-energized (no power), the valve remains closed, preventing fluid flow. When the solenoid coil is energized (power applied), the valve opens, allowing fluid to pass through.
- ڪوئل کي توانائي ڏيڻ: Applying the specified voltage to the solenoid coil will open the valve.
- ڪوئلي کي توانائي کان خالي ڪرڻ: Removing power from the solenoid coil will close the valve.
Monitor system pressure and flow rates after initial operation to ensure proper function and detect any anomalies.
6. سار سنڀال
6.1 روين جي چڪاس
- Periodically check for external leaks around the connections and valve body.
- Inspect the solenoid coil for any signs of overheating, damage, or loose connections.
- Listen for unusual noises during operation, which may indicate internal issues.
6.2 صفائي
- Keep the exterior of the valve clean and free from dust, dirt, and corrosive substances.
- If internal cleaning is required, consult a qualified technician or Danfoss service representative. Disassembly by untrained personnel can void warranty and cause damage.
6.3 Coil Replacement
If the solenoid coil fails, it can typically be replaced without removing the entire valve from the system. Ensure the power is disconnected before attempting coil replacement. Refer to the specific coil's instructions for detailed replacement procedures.
7. مسئلا حل ڪرڻ
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| Valve does not open when energized. |
|
|
| Valve does not close when de-energized. |
|
|
| Leakage from valve connections. |
|
|
8. وضاحتون
| وصف | قدر |
|---|---|
| برانڊ | ڊينفوس |
| ماڊل نمبر | 032F1204 (Part Number: G2401.38S) |
| قسم | Solenoid Valve, Normally Closed (NC) |
| ڪنيڪشن جو قسم | 3/8 inch ODF (Outside Diameter Flared) |
| شيءِ جو وزن | 8 ounces (approx. 0.5 LBR) |
| پيداوار جي ماپ (L x W x H) | 5.37 x 2.5 x 4 انچ |
| UPC-EAN | 5702422004189 |
| ٺاهيندڙ | ڊينفوس |
| تاريخ پهرين دستياب | ڊسمبر 14، 2016 |
9. وارنٽي ۽ سپورٽ
پراڊڪٽ وارنٽي، ٽيڪنيڪل سپورٽ، يا سروس بابت معلومات لاءِ، مھرباني ڪري سڌو سنئون ڊين فاس سان رابطو ڪريو يا انھن جي سرڪاري آفيس جو دورو ڪريو. website. Danfoss provides comprehensive support for its products to ensure customer satisfaction and optimal performance.
ڊين فاس آفيشل Webسائيٽ: www.danfoss.com