PNI PG200

PNI PG200 GSM/PSTN وائرليس الارم سسٽم يوزر مينوئل

ماڊل: PG200

1. تعارف

This manual provides detailed instructions for the installation, operation, and maintenance of your PNI PG200 GSM/PSTN Wireless Alarm System. Please read this manual thoroughly before using the system to ensure proper functionality and safety. This system is designed to provide security for your premises using a combination of wireless and wired sensors, communicating alerts via GSM and landline networks.

2. پراڊڪٽ ختمview ۽ اجزاء

The PNI PG200 alarm system includes a main control panel, various sensors, remote controls, and a siren. Understanding each component is crucial for effective system setup and operation.

PNI PG200 Alarm System Kit in packaging with main unit, sensors, and remotes

شڪل 2.1: The PNI PG200 Wireless Alarm System kit, showing the main control unit, remote controls, siren, motion sensor, and door/window sensor, both in packaging and as individual components.

All PNI PG200 alarm system components laid out

شڪل 2.2: هڪ مڪمل view of all components included with the PNI PG200 system, including the main panel, power adapter, siren, remote controls, motion sensor, and door/window sensor.

2.1 مين ڪنٽرول پينل

Close-up of PNI PG200 main control panel front

شڪل 2.3: سامهون view of the PNI PG200 main control panel, featuring an LCD display, numeric keypad, and function buttons for arming, disarming, and intelligent modes.

Close-up of PNI PG200 main control panel rear ports

شڪل 2.4: ريڙهه view of the PNI PG200 main control panel, showing ports for Line 1, Line 2 (landline connections), Power input, Siren output, and an On/Off switch.

The main control panel is the central unit of the alarm system. It features an LCD display, a numeric keypad for inputting codes, and buttons for various functions such as Arming, Intelligent Arming, and Disarming. It also houses the GSM module and connections for landlines.

2.2 ريموٽ ڪنٽرول

Close-up of PNI PG200 remote controls

شڪل 2.5: Two remote controls for the PNI PG200 system, each with buttons for arming, disarming, and panic functions, and an extendable antenna.

Two remote controls are provided for convenient arming and disarming of the system from a distance. They typically include buttons for full arming, disarming, and a panic function.

2.3 وائرليس موشن سينسر

Close-up of PNI PG200 wireless motion sensor

شڪل 2.6: A wireless passive infrared (PIR) motion sensor for the PNI PG200 system, designed to detect movement within its coverage area.

The system includes wireless motion sensors (PIR sensors) that detect movement within their field of view. These sensors communicate wirelessly with the main control panel.

2.4 سائرن

A 110 dB siren is included to provide an audible alert during an alarm event. It connects to the main control panel and can deter intruders.

3. سيٽ اپ ۽ تنصيب

Careful installation is essential for the optimal performance of your alarm system.

3.1 Main Control Panel Installation

  1. لڳائڻ: Choose a central location for the main control panel, away from direct sunlight, heat sources, and areas prone to moisture. Ensure it is within range of your wireless sensors and has access to a power outlet and, if used, a landline connection.
  2. چڙهڻ: The unit can be self-adhesive or mounted using screws (not specified if included). Secure the main panel firmly to a wall at an accessible height.
  3. پاور ڪنيڪشن: Connect the provided DC power adapter to the 'POWER' input on the rear of the main panel (refer to Figure 2.4). Plug the adapter into a standard electrical outlet.
  4. Siren Connection: Connect the included siren to the 'SIREN' output port on the rear of the main panel.

3.2 SIM Card and Landline Connection

  1. سم ڪارڊ داخل ڪرڻ: Open the SIM card slot cover (location not specified, typically on the side or rear). Insert a standard GSM SIM card into the designated slot. Ensure the SIM card is active and has sufficient credit for calls and SMS messages.
  2. Landline Connection: If using a landline, connect your telephone line(s) to the 'LINE 1' and/or 'LINE 2' ports on the rear of the main panel (refer to Figure 2.4).

3.3 سينسر جي انسٽاليشن ۽ جوڙو ٺاهڻ

The system supports 99 wireless zones and 2 wired zones.

  1. Wireless Sensor Placement: Install wireless motion sensors in areas where intrusion is likely, such as hallways, entry points, or rooms with valuables. Install door/window sensors on all entry points. Ensure sensors are placed within the wireless range of the main panel.
  2. Wired Sensor Connection: For the 2 wired zones, connect compatible wired sensors (e.g., magnetic contacts, vibration sensors) to the designated wired input terminals on the main panel (refer to product diagram for exact location, not explicitly shown in provided images).
  3. Pairing Wireless Sensors: Refer to the specific instructions in your full user manual for the pairing process. Generally, this involves putting the main panel into a 'learning' or 'pairing' mode and then triggering each wireless sensor (e.g., opening a door, waving in front of a motion sensor) to register it with the system. Assign each sensor to a specific zone.

4. آپريٽنگ هدايتون

The PNI PG200 offers multiple ways to control your alarm system.

4.1 هٿياربند ۽ غير مسلح ڪرڻ

  • Via Keypad: Enter your user code on the main panel's keypad and press the 'ARMING' button for full arming or 'INTELLIGENT' for partial arming. Enter your user code and press 'DISARMING' to disarm the system.
  • ريموٽ ڪنٽرول ذريعي: Press the 'Arm' button on your remote control for full arming. Press the 'Disarm' button to disarm. Remote controls have a range of up to 100m in open fields.
  • Via SMS/Call: The system supports remote control via SMS commands or voice calls. Specific commands will be detailed in the full user manual. You can send an SMS with a specific code or call the system's number and enter a sequence of keys to arm or disarm.

4.2 Smart Home Arming (Zone-Specific)

The system allows for partial arming, where only specific zones are armed. This is useful when you are at home and want to secure certain areas (e.g., perimeter sensors) while moving freely in others. Consult your full user manual for instructions on configuring and activating zone-specific arming.

4.3 الارم نوٽيفڪيشن

Upon detection of an intrusion, the system will activate the siren and send alerts to up to 6 pre-programmed phone numbers (mobile or landline) via SMS or voice call, utilizing both GSM and landline communication modules.

5. سار سنڀال

Regular maintenance ensures the longevity and reliability of your alarm system.

  • بيٽري چيڪ: The system includes a backup battery. Periodically check the battery status indicator on the main panel. Replace batteries in wireless sensors as needed (typically indicated by a low battery warning on the sensor or main panel).
  • صفائي: Clean the main panel and sensors with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • سسٽم ٽيسٽ: Periodically test the system by triggering a sensor while armed to ensure the siren activates and notifications are sent.

6. مسئلا حل ڪرڻ

If you encounter issues with your PNI PG200 system, refer to the following common problems and solutions:

  • System Not Arming: Ensure all zones are closed (doors/windows shut, no motion detected). Check for low battery warnings from sensors.
  • No SMS/Call Alerts: Verify the SIM card is correctly inserted, active, and has credit. Check landline connection. Ensure emergency numbers are correctly programmed.
  • غلط الارم: Check sensor placement for environmental factors (e.g., pets, drafts, direct sunlight on motion sensors). Ensure sensors are securely mounted.
  • ريموٽ ڪنٽرول ڪم نه ڪري رهيو آهي: Check the remote control's battery. Ensure you are within range of the main panel.

For more complex issues, consult the comprehensive user manual or contact PNI customer support.

7. وضاحتون

برانڊPNI
ماڊل نمبرپي جي 200
ٺاهيندڙONLINESHOP SRL
پيداوار جي ماپ (L x W x H)32.5 x 24.5 x 7.3 سينٽي
شيءِ جو وزن490 گرام
رنگاڇو
طاقت جو ذريعوDC
جلدtage12 وولٽ
انسٽاليشن جو طريقوخود چپکڻ وارو
آواز جي سطح110 ڊيسيبل
خاص خاصيتون99 Wireless Zones + 2 Wired Zones, Remote Arming, GSM and Landline Communication
استعمالصرف اندروني استعمال
شامل اجزاءMain board, metal casing, LCD keypad, user manual
بيٽري (ies) شامل آهنها
مطابقت رکندڙ ڊوائيسزاسمارٽ فون
رابطي ٽيڪنالاجيوائرڊ ، وائرليس
انتباہ جو قسمصرف حرڪت
ڪنٽرول جو طريقوريموٽ ڪنٽرول

8. وارنٽي ۽ سپورٽ

For warranty information and technical support, please refer to the documentation included with your product or visit the official PNI webسائيٽ. ڪنهن به وارنٽي دعوائن لاءِ خريداري جي ثبوت طور پنهنجي خريداري جي رسيد رکو.

لاڳاپيل دستاويز - پي جي 200

اڳيview PNI S002 Wired Outdoor Siren - User Manual and Technical Specifications
Comprehensive user manual for the PNI S002 wired outdoor siren, detailing features, installation, technical specifications, and connection diagrams for alarm systems.
اڳيview PNI SafeHouse HS650 وائرليس الارم سسٽم يوزر مينوئل
PNI SafeHouse HS650 وائرليس الارم سسٽم لاءِ جامع يوزر مينوئل، جيڪو Tuya Smart ايپ سان خاصيتون، تنصيب، ترتيب، ۽ آپريشن کي ڍڪيندو آهي.
اڳيview گيٽ آٽوميشن سسٽم لاءِ PNI RC800 ريموٽ ڪنٽرول - يوزر مينوئل
PNI RC800 ريموٽ ڪنٽرول لاءِ استعمال ڪندڙ مينوئل، حفاظت بابت هدايتون مهيا ڪرڻ، PNI AP800C ۽ PNI MAB300 سسٽم سان جوڙڻ، ٽيڪنيڪل وضاحتون، ۽ EU مطابقت.
اڳيview PNI Escort HP 62DE پورٽبل سي بي ريڊيو يوزر مينوئل
PNI Escort HP 62DE پورٽيبل CB ريڊيو لاءِ استعمال ڪندڙ دستياب. قابل اعتماد رابطي لاءِ ان جي خاصيتن، آپريشن، حفاظتي احتياط، ۽ ٽيڪنيڪل وضاحتن بابت سکو.
اڳيview PNI SafeHouse HS600 وائرليس الارم سسٽم يوزر مينوئل
Comprehensive user manual for the PNI SafeHouse HS600 wireless alarm system, detailing its main functions, installation, configuration, and operation via the Tuya Smart app. Learn about its advanced features for home security.
اڳيview PNI SafeHouse HS003 Wireless Motion Sensor User Manual
Comprehensive user manual for the PNI SafeHouse HS003 wireless motion sensor. Covers product information, main functions, description, LED indicators, PCB layout, installation, testing, detection range, technical parameters, and troubleshooting. Includes EU Declaration of Conformity link.