DIGITEN DHC101

DIGITEN DHC101 Digital Humidity Controller

استعمال ڪندڙ جي ھدايت وارو دستور

1. پراڊڪٽ ختمview

The DIGITEN DHC101 is a pre-wired digital humidistat designed for precise humidity control. It supports both humidification and dehumidification modes, making it suitable for a wide range of applications such as grow tents, mushroom cultivation, greenhouses, reptile enclosures, homebrewing, and more. The controller features a clear LED display, easy-to-use buttons, and a sensitive external sensor probe to accurately monitor and regulate humidity levels.

DIGITEN DHC101 Humidity Controller with sensor and power cables.

The DIGITEN DHC101 Humidity Controller, featuring a digital display, sensor probe, and pre-wired power outlet and plug.

Key features of DIGITEN DHC101 Humidity Controller including dehumidifying/humidifying, humidity percent, large screen, and alarm.

هڪ اوورview highlighting the controller's main features: dual-mode operation (humidifying/dehumidifying), percentage humidity display, large LED screen for readability, and an integrated alarm function.

2. سيٽ اپ جون هدايتون

  1. پيڪنگ کولڻ: Carefully remove the DHC101 controller and its accessories from the packaging. Ensure all components are present: the main controller unit, the external humidity sensor probe, and the pre-wired power cables.
  2. سينسر ڪنيڪشن: Locate the small jack on the side of the controller unit. Insert the plug of the external humidity sensor probe firmly into this jack. Ensure a secure connection.
  3. Humidity sensor probe for DIGITEN DHC101.

    The external humidity sensor probe with its connecting cable, designed for accurate environmental monitoring.

  4. لڳائڻ: Position the controller unit in a stable location. The unit can be hung using the integrated hanging hole or placed on a flat surface. Ensure the sensor probe is placed within the environment where humidity needs to be controlled, away from direct water spray or extreme temperatures that could affect its accuracy.
  5. پاور ڪنيڪشن: Plug the controller's main power plug into a standard electrical outlet. The LED display will illuminate, showing the current humidity reading.
  6. ڊوائيس ڪنيڪشن: Plug your humidifying or dehumidifying appliance (e.g., humidifier, dehumidifier, exhaust fan) into the pre-wired outlet on the DHC101 controller.

3. آپريٽنگ هدايتون

The DHC101 offers both humidification and dehumidification modes. The display shows the current humidity (PV), the set start humidity (SV), and the set stop humidity (DV).

Close-up of DIGITEN DHC101 display and ports.

تفصيلي view of the controller's illuminated LED display showing humidity readings and settings, along with the hanging hole, 3-prong grounded plug, and sensitive probe connection.

Setting Humidity Parameters:

  1. سيٽنگ موڊ داخل ڪريو: کي دٻايو ۽ رکو سيٽ button for 3 seconds to enter the parameter setting mode. The display will show 'F1'.
  2. پيرا ميٽر چونڊيو: استعمال ڪريو UP or هيٺ arrows to cycle through the parameters (F1, F2, F3, etc.).
  3. قدر کي ترتيب ڏيو: Once the desired parameter (e.g., F1 for start humidity) is displayed, press سيٽ ٻيهر ڏانهن view its current value. Use the UP or هيٺ arrows to adjust the value.
  4. سيٽنگ محفوظ ڪريو: دٻايو سيٽ to confirm and save the new value.
  5. سيٽنگ موڊ مان نڪرڻ: دٻايو ۽ رکو سيٽ for 3 seconds, or wait for 10 seconds without any button press, to exit the setting mode.

اهم پيٽرولر:

  • F1 (Start Humidity): Set the humidity percentage at which the connected device will activate.
  • F2 (Stop Humidity): Set the humidity percentage at which the connected device will deactivate.
  • F3 (Humidity Correction): Allows for calibration of the sensor reading if there is a known offset.
  • F4 (Delay Start Time): Sets a delay before the device activates, protecting compressors in certain appliances.
  • F5 (High Humidity Alarm): Set the upper humidity limit for an audible alarm.
  • F6 (Low Humidity Alarm): Set the lower humidity limit for an audible alarm.

The controller will automatically switch between humidification and dehumidification based on the F1 and F2 settings. If F1 < F2, it operates in humidification mode. If F1 > F2, it operates in dehumidification mode.

4. سار سنڀال

  • سينسر جي سنڀال: The humidity sensor is sensitive. Avoid submerging it in water or exposing it to corrosive substances. If the sensor becomes dirty, gently wipe it with a soft, dry cloth. Do not use abrasive cleaners.
  • يونٽ جي صفائي: Wipe the main controller unit with a soft, slightly damp cloth. Do not use strong detergents or solvents. Ensure the unit is unplugged before cleaning.
  • اسٽوريج: When not in use for extended periods, store the DHC101 in a cool, dry place, away from direct sunlight and extreme temperatures.

5. مسئلا حل ڪرڻ

  • Display Not On: Ensure the controller is securely plugged into a working power outlet. Check the power source.
  • Inaccurate Humidity Reading:
    • Verify the sensor probe is correctly connected to the unit.
    • Check the sensor's placement; it should be in the environment to be controlled, not obstructed or in direct contact with moisture.
    • Consider using the F3 (Humidity Correction) parameter to fine-tune the reading if you have a reference hygrometer.
  • Device Not Activating/Deactivating:
    • Confirm that the connected appliance is functioning correctly and is plugged firmly into the controller's outlet.
    • Review your F1 (Start Humidity) and F2 (Stop Humidity) settings to ensure they are appropriate for your desired operation mode (humidification or dehumidification).
    • Check the F4 (Delay Start Time) setting; a delay might be preventing immediate activation.
  • Alarm Sounds Continuously:
    • The alarm indicates that the humidity has exceeded the F5 (High Humidity Alarm) or fallen below the F6 (Low Humidity Alarm) threshold.
    • Adjust your F5/F6 alarm settings if the current range is too narrow for your application, or address the environmental condition causing the humidity excursion.

6. وضاحتون

خاصيتتفصيل
ماڊل نمبرDHC101
نمي ڪنٽرول رينج5% ~ 99% RH
جلدtage240 وولٽ
چڙهڻ جو قسمڀت جبل
بيٽري جي گهرجڪابه بيٽري جي ضرورت ناهي
ٺاهيندڙDIGITEN
پيڪيج جي ماپ8.23 x 8.23 x 1.73 انچ
شيءِ جو وزن14.99 اونس

7. وارنٽي ۽ سپورٽ

DIGITEN provides a one-year warranty for any product quality problems. If you encounter any issues with your DHC101 Humidity Controller, please contact DIGITEN customer support for assistance. Ensure you have your purchase details and model number (DHC101) ready when contacting support.

لاڳاپيل دستاويز - DHC101

اڳيview DIGITEN DHTC-1011 گرمي پد ۽ نمي ڪنٽرولر استعمال ڪندڙ دستياب
DIGITEN DHTC-1011 گرمي پد ۽ نمي ڪنٽرولر لاءِ استعمال ڪندڙ دستياب، ان جي خاصيتن، وضاحتن، سيٽنگ جي هدايتن، ۽ خرابي جي حل جي تفصيل سان.
اڳيview ٽائمر يوزر مينوئل سان Digiten TTC-1003 ٽمپريچر ڪنٽرولر
ٽائمر سان Digiten TTC-1003 ٽمپريچر ڪنٽرولر لاءِ استعمال ڪندڙ دستياب، هڪ 3-آئوٽليٽ ٿرموسٽٽ جيڪو پالتو جانورن جي پالڻ وارن ۽ ماحولياتي ڪنٽرول لاءِ ٺهيل آهي. ان جي خاصيتن، وضاحتن، ۽ پالتو جانورن جي بهترين آرام لاءِ گرمي، کولنگ، ۽ ٽائيمنگ افعال کي ڪيئن سيٽ اپ ڪجي بابت سکو.
اڳيview Digiten DTC-101 / DTC-151 ڊجيٽل گرمي پد ڪنٽرولر صارف دستياب ۽ وضاحتون
Digiten DTC-101 ۽ DTC-151 ڊجيٽل گرمي پد ڪنٽرولرز لاءِ جامع گائيڊ، تفصيل سان خاصيتون، سيٽ اپ، آپريشن، ٽيڪنيڪل وضاحتون، ۽ صحيح درجه حرارت جي انتظام لاءِ مسئلا حل ڪرڻ.
اڳيview DIGITEN وائرليس ٿرموسٽٽ WTC100 WTC200 يوزر دستياب
DIGITEN وائرليس ٿرموسٽٽ ماڊلز WTC100 ۽ WTC200 لاءِ جامع يوزر مينوئل، جنهن ۾ خاصيتون، وضاحتون، سيٽ اپ، آپريشن، مسئلو حل ڪرڻ، ۽ وارنٽي شامل آهن.
اڳيview DIGITEN DTC-101/DTC-151 ٿرموسٽٽ مينوئل: خاصيتون، سيٽ اپ، ۽ مسئلو حل ڪرڻ
DIGITEN DTC-101 ۽ DTC-151 ٿرموسٽيٽس لاءِ جامع يوزر مينوئل، جنهن ۾ خاصيتون، ٽيڪنيڪل وضاحتون، پينل هدايتون، سيٽنگ پيرا ميٽرز، فنڪشن موڊس (هيٽنگ/ٿڌڻ)، الارم، ٽربل شوٽنگ، ۽ وارنٽي جي معلومات شامل آهن.
اڳيview DIGITEN وائرليس پول ٿرماميٽر WPT-100 يوزر دستياب
DIGITEN وائرليس پول ٿرماميٽر ماڊل WPT-100 لاءِ استعمال ڪندڙ دستياب، تفصيل سان خاصيتون، وضاحتون، سيٽ اپ، آپريشن، مسئلو حل ڪرڻ، ۽ وارنٽي جي معلومات.