1. تعارف
Thank you for choosing the Rossmax Swiss Design X5 Automatic Blood Pressure Monitor. This device is designed for accurate and reliable measurement of blood pressure and pulse rate at home. It incorporates advanced PARR (Pulse Arrhythmia) technology for early detection of Atrial Fibrillation (AFib), Premature Contraction (PC), Tachycardia, and Bradycardia during regular blood pressure checks. Please read this manual thoroughly before use to ensure proper operation and to maximize the benefits of this device.
2. حفاظت جي ڄاڻ
اهم: Always consult your physician for diagnosis and treatment. Self-diagnosis and treatment based on measurement results can be dangerous.
- هي ڊوائيس صرف بالغن جي استعمال لاء آهي.
- Do not use this device on infants, toddlers, or children.
- هي ڊوائيس بلڊ پريشر کي ماپڻ کان سواءِ ڪنهن به مقصد لاءِ استعمال نه ڪريو.
- Keep the device and cuff out of reach of children.
- ڊوائيس کي جدا ڪرڻ يا مرمت ڪرڻ جي ڪوشش نه ڪريو.
- Cardiac disorders require medical attention. The PARR technology assists in early diagnosis by detecting arrhythmia during blood pressure checks without additional user interaction or measurement prolongation.
- If you experience any discomfort during measurement, press the power button to immediately stop the inflation.
3. اجزاء اوورview
The Rossmax X5 Blood Pressure Monitor package includes the following components:
- Rossmax X5 Main Unit
- Universal Cone Cuff (24-40cm)
- هدايت نامو (هي دستاويز)
- 4 x AA بيٽريون (شامل)

شڪل 3.1: سامهون view of the Rossmax X5 Automatic Blood Pressure Monitor, showing the digital display, control buttons, and connected cuff.

شڪل 3.2: The Universal Cone Cuff (24-40cm) included with the Rossmax X5 monitor.
4. سيٽ اپ
4.1 بيٽري لڳائڻ
- يونٽ جي پوئين پاسي واري بيٽري جو ڍڪ کوليو.
- Insert four (4) AA size batteries according to the polarity indicators (+ and -) inside the compartment.
- بيٽري جي ڍڪ کي محفوظ طور تي بند ڪريو.
نوٽ: The device can also be powered by an optional AC adaptor (not included).

شڪل 4.1: پاسي view of the monitor, indicating the 6V DC power input and DATA port.

شڪل 4.2: A closer look at the 6V DC power input and DATA port for optional connectivity.
4.2 Cuff Connection
Insert the air plug of the cuff firmly into the air jack on the left side of the monitor. Ensure a secure connection to prevent air leakage during measurement.
5. آپريٽنگ هدايتون
5.1 ماپ کان اڳ
- ماپ کان گهٽ ۾ گهٽ 30 منٽ اڳ کائڻ، شراب پيئڻ، سگريٽ نوشي ۽ ورزش ڪرڻ کان پاسو ڪريو.
- ماپ وٺڻ کان پهريان گهٽ ۾ گهٽ 5 منٽن لاء آرام ڪريو.
- Sit upright with your back supported and feet flat on the floor.
- پنهنجو هٿ ٽيبل تي رکو ته جيئن ڪف دل جي سطح تي هجي.
- Ensure the cuff is applied directly to your bare arm, not over clothing.
5.2 ڪف لاڳو ڪرڻ
- Slide the end of the cuff through the metal ring to form a loop. The smooth cloth should be on the inside of the cuff loop.
- Place the cuff on your left upper arm so that the air tube runs down the inside of your arm.
- The bottom edge of the cuff should be approximately 2-3 cm (0.8-1.2 inches) above your elbow.
- Wrap the cuff snugly around your arm. Ensure it is not too tight or too loose.
5.3 ماپ وٺڻ
- کي دٻايو طاقت مانيٽر کي چالو ڪرڻ لاءِ بٽڻ.
- The cuff will automatically inflate. Remain still and silent during the measurement.
- Once the measurement is complete, the monitor will display your Systolic (SYS), Diastolic (DIA) blood pressure, and Pulse rate.
- The display will also show indicators for PARR technology (ARR/AFib/PC) if detected.
- The measurement will be automatically stored in the device's memory.
- The device will auto-shut-off approximately 1 minute after the last key operation.
5.4 Understanding Display Indicators
- ايس ايس: Systolic blood pressure (upper value).
- ڊي آءِ اي Diastolic blood pressure (lower value).
- PULSE /min: Your pulse rate in beats per minute.
- ARR: Arrhythmia detection.
- AFib: Atrial Fibrillation detection.
- PC: Premature Contraction detection.
- M: Memory indicator. The device stores 60 memories for each of two zones.
6. سار سنڀال
6.1 صفائي
- Clean the monitor and cuff with a soft, dry cloth.
- گھڙڻ وارا صاف ڪندڙ استعمال نه ڪريو يا ڊوائيس کي پاڻي ۾ نه ٻوڙيو.
6.2 اسٽوريج
- ڊوائيس کي ٿڌي، سڪل جاءِ تي، سڌي سج جي روشني ۽ انتهائي گرمي پد کان پري رکو.
- جيڪڏهن ڊوائيس گهڻي عرصي تائين استعمال نه ٿيندي، ته پوءِ ليڪيج کي روڪڻ لاءِ بيٽريون هٽايو.
7. مسئلا حل ڪرڻ
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| ڪو به ڊسپلي نه جڏهن پاور آن | بيٽريون ختم ٿي ويون آهن يا غلط طور تي لڳايون ويون آهن. | بيٽريون تبديل ڪريو يا پولارٽي چيڪ ڪريو. |
| ڪف نه ٿو ڦُلي يا ڪمزوري سان ڦُلي ٿو | Cuff not connected properly or air leakage. | Ensure cuff air plug is firmly inserted. Check cuff for damage. |
| غلط پڙھڻ | Improper cuff placement, movement during measurement, or incorrect posture. | Re-apply cuff correctly, remain still and silent, ensure proper posture. |
| ڊسپلي تي غلطي پيغام | Refer to the specific error code in the full manual (if available) or contact support. | Repeat measurement after resting. If error persists, contact customer support. |
For further assistance, please contact Rossmax customer support.
8. وضاحتون
| خاصيت | تفصيل |
|---|---|
| Measurement Range (Pressure) | 30 ~ 260 mmHg |
| Measurement Range (Pulse) | 40 ~ 199 بيٽس / منٽ |
| Accuracy (Pressure) | ± 3 ايم ايم ايڇ جي |
| Accuracy (Pulse) | پڙهڻ جو ± 5٪ |
| ياداشت جي صلاحيت | هر زون x 60 زونن لاءِ 2 ياداشتون |
| Deflation | خودڪار ايئر ڇڏڻ والو |
| خودڪار بند | آخري اهم آپريشن کان پوء 1 منٽ |
| ٺاهيندڙ | راسمڪس |
| اصل جو ملڪ | چين |
| پيداوار جي ماپ | 16.5 x 14 x 8 سينٽي |
| شيءِ جو وزن | 0.45 جي |
| طاقت جو ذريعو | Battery Powered, Adaptor facility |
| ڊسپلي جو قسم | ڊجيٽل |
| شامل اجزاء | ڪفن |
| بيٽريون | 2 AA بيٽريون گھربل (شامل) |
9. وارنٽي ۽ سپورٽ
The Rossmax X5 Automatic Blood Pressure Monitor comes with a 5-year lifetime calibration warranty. For any product-related queries, technical support, or warranty claims, please contact Rossmax customer support.
Rossmax Customer Support Number: 8884555054