GESAIL 05-742G

GESAIL Bird Bath Heater Instruction Manual

ماڊل: 05-742G

تعارف

The GESAIL Bird Bath Heater is designed to prevent bird bath water from freezing during winter, ensuring a continuous water source for birds and other small animals. This thermostatically controlled deicer operates only when necessary, providing a safe and energy-efficient solution for your outdoor bird bath.

Image showing a cardinal in snow and a frozen bird bath on one side, and a heated bird bath with the GESAIL deicer on the other, illustrating the product's purpose.

The GESAIL Bird Bath Heater ensures birds have access to unfrozen water even in cold winter conditions, contrasting with a frozen bird bath.

اهم حفاظتي هدايتون

  • استعمال ڪرڻ کان پهريان سڀ هدايتون احتياط سان پڙهو.
  • Ensure the heater is fully submerged in water before plugging it into a power outlet. Operating the heater out of water can cause damage and create a fire hazard.
  • Use only with a properly grounded 120V AC outlet. The heater features a safe 3-prong grounded plug.
  • هي پيداوار صرف ٻاهرين استعمال لاء ٺهيل آهي.
  • Do not use with an extension cord unless it is rated for outdoor use and is properly grounded.
  • Keep the power cord away from sharp objects, hot surfaces, and moving parts.
  • Do not attempt to open or repair the unit. Refer all servicing to qualified personnel.
  • صاف ڪرڻ يا ڪنهن به سار سنڀال ڪرڻ کان اڳ هميشه هيٽر کي ان پلگ ڪريو.
  • The heating element is enclosed in cast aluminum to protect animals from direct contact and scalding.
Close-up image of the GESAIL bird bath heater showing its internal heating coils and a 3-prong grounded plug, highlighting its safety features.

The GESAIL Bird Bath Heater features a safely enclosed heating element and a 3-prong grounded plug for enhanced safety.

پيداوار ختمview

The GESAIL Bird Bath Heater (Model 05-742G) is a 50W, 120V thermostatically controlled deicer crafted from heavy-duty cast aluminum. Its robust design ensures durability and resistance to rust, calcification, and staining. The heater is suitable for various bird bath materials, including metal, plastic, stone, and glass, without causing damage. The 25-inch PVC electric cord provides efficient and safe power delivery.

مٿي کان هيٺ view of the GESAIL bird bath heater, an off-white, oblong device with a gray power cord and a three-prong plug.

The GESAIL Bird Bath Heater, Model 05-742G, is designed for reliable performance.

ٽيڪنيڪل وضاحتون

تفصيلتفصيل
ماڊل نمبر05-742 جي
طاقت50 واٽ
جلدtage120 وولٽ
پيداوار جي ماپ6.5 x 2.75 x 1.5 انچ
شيءِ جو وزن1.06 پائونڊ
ڪنڊ ڊگھائي25 inches (PVC)
موادHeavy Duty Cast Aluminum
Thermostat ڪنٽرولها

سيٽ اپ ۽ تنصيب

Follow these steps to properly set up your GESAIL Bird Bath Heater:

  1. مناسب جڳھ چونڊيو: Place your bird bath in a stable location, ensuring it is easily accessible for maintenance and has a nearby outdoor, grounded 120V power outlet.
  2. هيٽر کي پوزيشن ڪريو: Gently place the GESAIL Bird Bath Heater in the center of your bird bath. The heater is weighted to remain at the bottom.
  3. Ensure Water Coverage: Fill the bird bath with water, making sure the heater is completely submerged. The thermostatic control requires full water immersion to function correctly and safely.
  4. پاور سان ڳنڍيو: Plug the 3-prong grounded plug into a suitable outdoor 120V AC grounded outlet. The heater will automatically begin to operate when the water temperature approaches freezing.
  5. آپريشن جو مشاهدو ڪريو: The heater will activate as needed to prevent ice formation. It will not significantly warm the water, only keep it from freezing.
A small blue bird perched on the edge of a bird bath, with the GESAIL bird bath heater submerged in the water, demonstrating proper placement.

Proper placement of the GESAIL Bird Bath Heater in a bird bath.

Watch this video for a visual guide on how the GESAIL Bird Bath Heater works to prevent freezing:

Official GESAIL video demonstrating the bird bath heater's function in preventing water from freezing in winter conditions.

آپريشن

The GESAIL Bird Bath Heater is designed for simple, automatic operation. Once plugged in and fully submerged, its integrated thermostat monitors the water temperature. It will only activate when the water temperature drops to near freezing, consuming power efficiently and preventing ice formation. The heater is specifically engineered not to significantly warm the water, maintaining a natural environment for birds while ensuring access to liquid water.

Two small birds splashing in a bird bath with water droplets visible, indicating the water is unfrozen and accessible.

Birds enjoying fresh, unfrozen water provided by the GESAIL Bird Bath Heater.

سنڀال ۽ سار سنڀال

  • باقاعده صفائي: The heavy-duty cast aluminum construction is designed to be easy to clean and resist calcification, rust, and stains. Periodically clean the heater and bird bath to remove debris and maintain hygiene. Always unplug the heater before cleaning.
  • پاڻي جي سطح برقرار رکڻ: Ensure the heater remains fully submerged in water at all times during operation. Check the water level regularly, especially during dry periods or if evaporation is high, and refill as needed.
  • موسمي ذخيرو: When not in use, especially during warmer months, unplug the heater, clean it thoroughly, and store it in a dry, safe place.
Diagram illustrating the durable features of the GESAIL bird bath heater: made of cast aluminum, no rust, easy to clean, and suitable for various bird bath types.

The GESAIL Bird Bath Heater is constructed from durable cast aluminum for easy cleaning and longevity.

مسئلا حل ڪرڻ واري گائيٽ

مسئلوممڪن سببحل
Heater is not preventing freezing.پلگ ان ٿيل ناهي، پاور او يوtage, insufficient water level, extreme cold.Check power connection. Ensure heater is fully submerged. Verify power to the outlet. In extremely low temperatures, a small amount of ice may form around the edges, but the center should remain clear.
Heater appears to be always on or off.Thermostat operating as designed, or unit malfunction.The thermostat activates only when water temperature approaches freezing. It will turn off when the water is above freezing. This is normal operation. If it seems to malfunction, ensure proper water level and contact customer support.
Water is heating up too much.Incorrect product expectation.This heater is designed to prevent freezing, not to heat the water significantly. The water will remain cold but liquid.
Power cord is too short.Standard cord length.Use an outdoor-rated extension cord if necessary, ensuring it is properly grounded and suitable for outdoor conditions.

وارنٽي ۽ ڪسٽمر سپورٽ

GESAIL stands behind the quality of its products. This Bird Bath Heater is covered by a manufacturer's warranty against defects in materials and workmanship under normal use. Please refer to the product packaging or the GESAIL official webمخصوص وارنٽي شرطن ۽ مدت لاءِ سائيٽ.

For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact GESAIL Customer Support through the retailer where the product was purchased or visit the official GESAIL webرابطي جي معلومات لاء سائيٽ.

رابطي جي ڄاڻ:
Manufacturer: GESAIL
Webسائيٽ: GESAIL Store on Amazon (عام پڇا ڳاڇا ۽ پراڊڪٽ جي معلومات لاءِ)

لاڳاپيل دستاويز - 05-742 جي

اڳيview Eberspächer Airtronic / Airtronic M Technical Manual: Installation, Operation, and Maintenance
Comprehensive guide for Eberspächer Airtronic 2/4 series air heaters, covering technical specifications, installation procedures, operation, maintenance, and troubleshooting. Includes details on Airtronic D2, D4, and B4 models.
اڳيview Eberspächer Airtronic S3, M3, L3, XL3 Technical Description and Installation Guide
Comprehensive technical description and installation guide for Eberspächer Airtronic S3, M3, L3, and XL3 commercial and recreational engine-independent air heaters. Covers product specifications, installation procedures, operation, maintenance, and safety regulations.
اڳيview ايبرسپيچر ايئرٽرونڪ ڊي 2 ڊيزل ايئر هيٽر: لڳائڻ ۽ انسٽاليشن گائيڊ
هي گائيڊ Eberspächer AIRTRONIC D2 ڊيزل ايئر هيٽر لاءِ جامع ٽيڪنيڪل وضاحتون ۽ انسٽاليشن جون هدايتون مهيا ڪري ٿو. اهو ضروري ٽيڪنيڪل ڊيٽا، حفاظتي ضابطن، ۽ مختلف گاڏين جي ايپليڪيشنن لاءِ آپريشنل هدايتن کي ڍڪيندو آهي، محفوظ ۽ ڪارآمد انسٽاليشن کي يقيني بڻائيندو آهي.
اڳيview Eberspächer Airtronic S2 & M2 Technical Description and Installation Guide
Comprehensive technical description and installation guide for Eberspächer Airtronic S2 and Airtronic M2 diesel and petrol air heaters. Covers product information, installation procedures, operation, maintenance, safety, and electrical diagrams.
اڳيview Eberspächer Hydronic S3 Commercial Technical Description & Installation Guide
Comprehensive technical description and installation guide for the Eberspächer Hydronic S3 Commercial auxiliary diesel heater, covering product information, installation procedures, operation, electrical diagrams, and troubleshooting.
اڳيview Eberspächer Airtronic S2 & M2 Vehicle Heater Repair Manual
Official repair instructions and technical guide for Eberspächer Airtronic S2 and M2 commercial and recreational vehicle air heaters, covering troubleshooting, maintenance, and specifications.