پيداوار ختمview
The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.
اهم خاصيتون شامل آهن:
- Designed for conditioning and extending the life of your probes.
- Made with reagent grade chemicals to ensure optimal performance of your pH probes.
- Double-sealed packaging to ensure freshness and prevent leakage.
- Expiration date clearly specified on the bottle for proper inventory management.
سيٽ اپ ۽ تياري
Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

تصوير: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.
آپريٽنگ هدايتون
Routine Electrode Storage
To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.
- Ensure the electrode is clean.
- اليڪٽرروڊ مان حفاظتي ڪيپ کي هٽايو.
- Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
- Place the electrode into the solution, ensuring the sensing part is completely submerged.
- Secure the electrode in the solution to prevent spillage and evaporation.
Restoring Dry or Sluggish Electrodes
If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.
- Clean the electrode thoroughly.
- Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
- Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
- After soaking, rinse the electrode with distilled water and perform a calibration before use.
Maintenance and Storage of Solution
To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:
- اسٽوريج جي درجه حرارت: Store the solution between 5°C and 30°C (41°F and 86°F). Avoid extreme temperatures.
- سيل ڪرڻ: Always keep the container tightly closed when not in use to prevent evaporation and contamination. The double-sealed packaging helps maintain freshness.
- مدو ختم ٿيڻ جي تاريخ: Refer to the expiration date printed on the bottle. Do not use the solution past its expiration date, as its chemical properties may degrade, affecting its effectiveness.
- آلودگي: Avoid introducing foreign substances into the solution. If the solution appears cloudy or discolored, it may be contaminated and should be replaced.
مشڪلاتون
This section addresses common issues related to electrode performance and how the storage solution can help.
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| Electrode shows unstable readings or slow response. | Electrode membrane is dry or dehydrated. | Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged. |
| Electrode requires frequent calibration. | Improper storage leading to degradation of electrode performance. | Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking. |
| Solution appears cloudy or contaminated. | Exposure to contaminants or expired solution. | Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution. |
وضاحتون
| وصف | تفصيل |
|---|---|
| پيداوار جو نالو | 3M KCL Storage Soaking Solution |
| ماڊل نمبر | اي 1107 |
| برانڊ | ايپيرا اوزار |
| شيءِ جو مقدار | 8 فلوئڊ اونس (تقريبن 236 ملي ليٽر) |
| KCL Concentration | 3M (3 mol/L) |
| شيون فارم | مائع |
| پيڪيج جي ڄاڻ | بوتل |
| پيداوار جي ماپ | 6.3 x 1.97 x 2.36 انچ |
| شيءِ جو وزن | 9 آونس |
| اصل جو ملڪ | آمريڪا |
وارنٽي ڄاڻ
Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webسائيٽ تي وڃو يا سڌو سنئون انهن جي گراهڪ سپورٽ سان رابطو ڪريو.
مدد ۽ رابطو
For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webسائيٽ:
(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)