Apera Instruments 3M KCL Storage Soaking Solution

ماڊل: AI1107

برانڊ: اپيرا انسٽرومينٽس

پيداوار ختمview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

اهم خاصيتون شامل آهن:

سيٽ اپ ۽ تياري

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

تصوير: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

آپريٽنگ هدايتون

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. اليڪٽرروڊ مان حفاظتي ڪيپ کي هٽايو.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Clean the electrode thoroughly.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

مشڪلاتون

This section addresses common issues related to electrode performance and how the storage solution can help.

مسئلوممڪن سببحل
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

وضاحتون

وصفتفصيل
پيداوار جو نالو3M KCL Storage Soaking Solution
ماڊل نمبراي 1107
برانڊايپيرا اوزار
شيءِ جو مقدار8 فلوئڊ اونس (تقريبن 236 ملي ليٽر)
KCL Concentration3M (3 mol/L)
شيون فارممائع
پيڪيج جي ڄاڻبوتل
پيداوار جي ماپ6.3 x 1.97 x 2.36 انچ
شيءِ جو وزن9 آونس
اصل جو ملڪآمريڪا

وارنٽي ڄاڻ

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webسائيٽ تي وڃو يا سڌو سنئون انهن جي گراهڪ سپورٽ سان رابطو ڪريو.

مدد ۽ رابطو

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webسائيٽ:

www.aperainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

لاڳاپيل دستاويز - اي 1107

اڳيview کاڌي جي جاچ لاءِ اپيرا SX811-SS پورٽيبل پي ايڇ ميٽر: هدايت نامو ۽ وضاحتون
صحيح کاڌي جي جاچ لاءِ ٺهيل، اپيرا SX811-SS پورٽيبل پي ايڇ ميٽر لاءِ جامع هدايت نامو ۽ ٽيڪنيڪل وضاحتون. خاصيتن، ڪيليبريشن، سيٽ اپ، USB ڪميونيڪيشن، ۽ خرابي جي حل بابت سکو.
اڳيview PH60Z-HT سمارٽ پي ايڇ ميٽر استعمال ڪندڙ دستياب - اپيرا اوزار
اپيرا انسٽرومينٽس PH60Z-HT سمارٽ پي ايڇ ميٽر لاءِ استعمال ڪندڙ مينوئل، ان جي خاصيتن، آپريشن، ڪيليبريشن، سار سنڀال، ۽ اعليٰ درجه حرارت ۽ ڪاسٽڪ حلن لاءِ خرابين جي حل جي تفصيل سان.
اڳيview PH60Z-PW سمارٽ پي ايڇ-ميٽر Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Smart pH-Meter. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen in reinem Wasser.
اڳيview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
اڳيview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.
اڳيview APERA اوزار pH 4.00 بفر حل حفاظتي ڊيٽا شيٽ
APERA انسٽرومينٽس pH 4.00 بفر حل لاءِ حفاظتي ڊيٽا شيٽ (SDS)، سڃاڻپ، خطرن، پهرين امداد، هٿ ڪرڻ، اسٽوريج، ۽ ريگيوليٽري تعميل بابت ضروري معلومات فراهم ڪري ٿي.