This manual provides essential information for the proper use, maintenance, and storage of the 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100, model 60927. This product is designed to be used with compatible 3M half and full facepiece respirators featuring a bayonet-style connection.
The 3M 60927 cartridge/filter is NIOSH-approved for protection against mercury vapor, chlorine, sulfur dioxide, organic vapor, and hydrogen sulfide. It also includes a P100 particulate filter for protection against certain oil and non-oil based particulates.

شڪل 1: سامهون view of the 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927. The magenta color indicates its specific protection capabilities.
2. حفاظت جي ڄاڻ
خبردار: Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. These products are intended for workplace use by trained industrial and occupational customers. They are not intended for consumer use.
- Always refer to NIOSH guidelines for proper use of respiratory protection equipment.
- Consult the respirator manufacturer's instructions for specific attachment procedures and compatibility.
- Ensure the cartridge is appropriate for the specific contaminants and concentrations present in your work environment.
- Do not use in atmospheres immediately dangerous to life or health (IDLH).
- سينڊ بلاسٽنگ لاءِ استعمال نه ڪريو.
- Leave the contaminated area immediately if breathing becomes difficult, dizziness or other distress occurs, or if you smell or taste contaminants.
- Replace cartridges according to a change-out schedule or sooner if breakthrough occurs.
- Store unused cartridges in their original packaging in a clean, dry area away from contaminants.
پراڊڪٽ جي چونڊ ۽ استعمال ۾ مدد لاءِ، پنهنجي سائيٽ تي موجود حفاظتي پيشيور، صنعتي صفائي ڪندڙ، يا ٻئي موضوع جي ماهر سان صلاح ڪريو.
3. سيٽ اپ ۽ تنصيب
The 3M 60927 Cartridge/Filter is designed for easy attachment to compatible 3M half and full facepiece respirators using a bayonet connection system.
3.1 گهربل سامان
- 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 (Model 60927)
- Compatible 3M Half or Full Facepiece Respirator (sold separately)
3.2 تنصيب جا مرحلا
- اجزاء جي چڪاس ڪريو: Before each use, inspect the cartridge/filter and the respirator facepiece for any signs of damage, cracks, or wear. Do not use damaged equipment.
- Align Cartridge: Align the bayonet connection on the cartridge with the corresponding receptacle on the respirator facepiece. The cartridge should be oriented so the 3M logo and model number are visible and facing outwards.
- Attach Cartridge: Push the cartridge onto the receptacle and twist clockwise approximately a quarter turn until it clicks into place. Ensure both cartridges (if using a dual-cartridge respirator) are securely attached.
- مهر جي چڪاس ڪريو: Conduct a positive and/or negative pressure user seal check as described in your respirator's instruction manual to ensure a proper fit and seal.

شڪل 2: هيٺيون view of the 3M 60927 cartridge, highlighting the bayonet connection point for attachment to a respirator.
4. آپريٽنگ هدايتون
Once properly installed on a compatible 3M respirator and a successful user seal check has been performed, the 3M 60927 cartridge/filter provides respiratory protection.
- پائڻ جو وقت: The service life of the cartridge depends on various factors including contaminant concentration, breathing rate, humidity, and temperature. Follow your employer's change-out schedule or local regulations.
- Contaminant Detection: The cartridge is designed to filter specific gases, vapors, and particulates. If you detect the smell or taste of contaminants, or experience irritation, immediately leave the contaminated area and replace the cartridges.
- P100 Particulate Filter: The integrated P100 filter provides high-efficiency particulate filtration against both oil and non-oil based aerosols.

Figure 3: An industrial worker utilizing respiratory protection, demonstrating a typical application environment for the 3M 60927 cartridge.
5. مينٽيننس ۽ اسٽوريج
5.1 ڪارٽريج جي متبادل
Cartridges must be replaced when:
- Contaminants are detected by smell, taste, or irritation.
- Breathing resistance significantly increases.
- The established change-out schedule is reached.
- ڪارٽريج خراب آهي.
To replace, twist the used cartridge counter-clockwise to detach it from the respirator. Dispose of used cartridges according to local regulations. Install new cartridges following the "Setup and Installation" steps.
5.2 اسٽوريج
Store unused cartridges in their original, sealed packaging in a clean, dry, and cool environment, away from direct sunlight and contaminants. Do not store near chemicals or in areas with high humidity.
6. مسئلا حل ڪرڻ
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| Smell/Taste of Contaminants | Cartridge breakthrough, improper seal, cartridge expired, wrong cartridge type. | Immediately leave contaminated area. Replace cartridges. Re-check seal. Ensure correct cartridge for hazard. |
| Difficulty Breathing | Cartridges clogged with particulates, high breathing rate, physical exertion. | Immediately leave contaminated area. Replace cartridges. Reduce exertion. |
| Cartridge not attaching securely | Improper alignment, damaged bayonet connection on cartridge or respirator. | Ensure correct alignment and twist until click. Inspect for damage; replace if necessary. |
| Discomfort or Irritation | Improper fit, allergic reaction to materials, contaminants bypassing seal. | Re-adjust respirator fit. Perform seal check. Consult safety professional. |
7. وضاحتون
| خاصيت | تفصيل |
|---|---|
| ماڊل نمبر | 60927 |
| برانڊ | 3M |
| تحفظ جو قسم | Mercury Vapor, Organic Vapor, Acid Gas, P100 Particulate |
| NIOSH جي منظوري | ها |
| ڪنيڪشن جو قسم | ـ Bayonet |
| رنگ | ميگنٽا |
| پيداوار جي ماپ (L x W x H) | 17.3 x 15.1 x 11.1 inches (packaging dimensions, individual cartridge smaller) |
| تاريخ پهرين دستياب | جنوري 14، 2020 |
| ٺاهيندڙ | 3M |
8. وارنٽي ۽ سپورٽ
3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers.
For additional product information, technical support, or warranty details, please visit the official 3M website or contact your local 3M representative. It is crucial to select and use products in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations.