Allanson 2721-628G

Allanson Ignition Transformer User Manual

Model: 2721-628G for Becket A, AF, AFG Burners

تعارف

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Allanson Ignition Transformer, Model 2721-628G. This transformer is specifically designed for use with Becket A, AF, and AFG series oil burners. Please read this manual thoroughly before attempting any installation or service.

حفاظت جي ڄاڻ

خبردار: Electrical shock hazard. Installation and servicing of this product must be performed by a qualified technician. Disconnect all power to the burner and heating system before installing, servicing, or removing the ignition transformer.

پيداوار ختمview

The Allanson Ignition Transformer (Model 2721-628G) is a critical component in oil burner systems, responsible for generating the high voltage required to ignite the fuel. It converts standard line voltage to a high-voltage spark, ensuring reliable ignition.

Allanson Ignition Transformer, front view ليبل سان

This image shows the Allanson Ignition Transformer, Model 2721-628G, from a front-top perspective. The primary label is visible, indicating "PRIMARY 120 V 60 HZ 250 VA" and "SECONDARY 10,000 V 23 MA". Two high-voltage terminals with springs are visible at the top, along with input wires extending from the sides. The unit is black with a green circular sticker on the side.

Allanson Ignition Transformer, side view

This image displays a side view of the Allanson Ignition Transformer. One of the high-voltage terminals with its spring is clearly visible, along with the input wiring. The mounting bracket is also visible on the side, and the green circular sticker is prominent on the main body of the transformer.

سيٽ اپ ۽ تنصيب

Installation of the ignition transformer should only be performed by a qualified HVAC technician or electrician. Incorrect installation can lead to equipment damage, fire, or serious injury.

  1. پاور ڪنيڪشن: Before starting, ensure all electrical power to the oil burner and heating system is completely disconnected at the main service panel. Verify with a voltagاي جاچ ڪندڙ.
  2. Access Old Transformer: Locate the existing ignition transformer on your Becket A, AF, or AFG burner. Note its mounting position and wiring connections.
  3. وائرنگ ختم ڪريو: Carefully disconnect the primary (low voltage) and secondary (high voltage) wiring from the old transformer. Label wires if necessary to ensure correct reconnection.
  4. Remove Old Transformer: Unmount the old transformer from its bracket or housing.
  5. Mount New Transformer: Mount the new Allanson 2721-628G transformer in the same location and orientation as the old one. Ensure it is securely fastened.
  6. وائرنگ ڳنڍڻ:
    • Connect the primary (120V) input wires to the designated terminals on the new transformer. Refer to the burner's wiring diagram for specific connections.
    • Connect the secondary (high voltage) output wires to the electrodes of the oil burner. Ensure a secure and proper connection to the spark gap.
  7. ڪنيڪشن جي تصديق ڪريو: Double-check all wiring connections for tightness and correctness according to the burner's specifications. Ensure no wires are pinched or exposed.
  8. بجلي بحال ڪريو ۽ ٽيسٽ ڪريو: Once all connections are secure and verified, restore power to the burner. Initiate a call for heat and observe the ignition sequence. The transformer should produce a strong, consistent spark.

آپريٽنگ اصول

The Allanson Ignition Transformer operates by stepping up the incoming 120V AC line voltage to a high voltage (10,000V) at a low current (23mA). This high voltage is then applied across the burner electrodes, creating an electrical arc (spark) that ignites the atomized fuel oil. The transformer is designed for intermittent duty, meaning it only operates during the ignition cycle of the burner, typically for a few seconds until stable combustion is established.

سار سنڀال

Regular maintenance helps ensure the longevity and reliable operation of your ignition transformer. All maintenance should be performed by a qualified technician with power disconnected.

مشڪلاتون

If your oil burner is experiencing ignition issues, the ignition transformer may be a contributing factor. Always ensure power is disconnected before inspecting components.

مسئلوممڪن سببحل
No Spark at Electrodes
  • No power to transformer
  • لوز يا منقطع وائرنگ
  • Internal transformer failure
  • Faulty primary control
  • سرڪٽ بريڪر ۽ وائرنگ چيڪ ڪريو.
  • معائنو ڪريو ۽ سڀني ڪنيڪشن کي محفوظ ڪريو.
  • Test transformer with a high-voltage tester (qualified technician only). Replace if faulty.
  • Consult burner manual for primary control troubleshooting.
ڪمزور يا وقفي وقفي سان چنگاري
  • Dirty or improperly gapped electrodes
  • Contaminated transformer terminals
  • Aging or failing transformer
  • Clean and adjust burner electrodes.
  • Clean transformer terminals and high-voltagاي تار.
  • Test transformer output. Replace if output is low.
Transformer Overheating/Humming
  • Short circuit in secondary wiring or electrodes
  • Internal transformer fault
  • Operating beyond rated duty cycle
  • Inspect electrodes and high-voltage wiring for shorts.
  • ٽرانسفارمر تبديل ڪريو.
  • Ensure primary control is cycling transformer correctly.

If troubleshooting steps do not resolve the issue, it is recommended to contact a qualified HVAC technician for further diagnosis and repair.

وضاحتون

وصفتفصيل
برانڊAllanson
ماڊل نمبر2721-628 جي
پرائمري جلدtage120 V
تعدد60 هز
Primary VA250 VA
ثانوي جلدtage10,000 V
ثانوي موجوده23 ايم اي
پيڪيج جي ماپ7.2 x 5.55 x 5.43 انچ
شيءِ جو وزن7.69 پائونڊ
ٺاهيندڙAllanson
وضاحت ميٽراي ٽي ايل

وارنٽي ڄاڻ

Specific warranty terms for the Allanson Ignition Transformer (Model 2721-628G) are provided by the manufacturer, Allanson. Please refer to the warranty documentation included with your purchase or visit the official Allanson website for detailed information regarding warranty coverage, duration, and claims procedures. Keep your proof of purchase for warranty purposes.

ڪسٽمر سپورٽ

For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact a qualified HVAC professional or refer to the official Allanson support channels. Contact information for Allanson can typically be found on their official webسائيٽ تي يا پراڊڪٽ پيڪنگنگ تي.

لاڳاپيل دستاويز - 2721-628 جي

اڳيview Allanson OMNI 2270U-3ST Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson OMNI 2270U-3ST universal electronic ignitor, featuring a built-in 3-second timer and diagnostic tool for oil burner systems. Includes technical specifications, dimensions, and contact information.
اڳيview Allanson 2270U-3ST OMNI Universal Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson 2270U-3ST OMNI Universal Electronic Ignitor, featuring a built-in 3-second timer and diagnostic capabilities for oil burner systems.
اڳيview ايلنسن انڊسٽريل گيس ٽرانسفارمر: وضاحتون ۽ ڪراس ريفرنس گائيڊ
ايلنسن انڊسٽريل گيس ٽرانسفارمرز لاءِ تفصيلي وضاحتون ۽ ڪراس ريفرنس چارٽ، جيڪي 1092-H، 1092-PF-G، ۽ ٻين جهڙن ماڊلز کي ڍڪيندا آهن، مختلف برنر ٺاهيندڙن لاءِ مطابقت جي معلومات سان.
اڳيview Allanson 2260 Series Electronic Ignitors Instruction Manual
Comprehensive instruction manual for Allanson 2260 series electronic ignitors (models 2260-TP, 2260-TPLP, 2260-TW, 2260-TWLP, 2260-P, 2260-TPLPJB). Includes installation, maintenance, testing, and mechanical specifications for commercial and industrial gas applications.
اڳيview Allanson ACL-SC-DMX DMX Sub-Controller Installation Manual
This installation manual provides detailed instructions for the Allanson ACL-SC-DMX DMX Sub-Controller, covering specifications, port configurations, wiring diagrams, and important safety precautions for RGBW lighting systems.
اڳيview Allanson CVW3125-120-277 Constant Voltage LED Power Supply - Class 2
Detailed specifications and features of the Allanson CVW3125-120-277 Constant Voltage LED Power Supply, a Class 2 driver designed for high-performance LED lighting applications with IP68 rating and 5-year warranty.