The Trane CNT07941 Control Circuit Board is an Original Equipment Manufacturer (OEM) component designed for American Standard and Trane HVAC systems. This board serves as a critical control unit, specifically a 1-stage, 120V HSI (Hot Surface Ignition), 1-speed inducer control board without a cover. It is a direct replacement for various older models, including CNT07541, BAF00434, CNT03797, and others.

This circuit board is essential for the proper functioning of compatible gas furnace models, managing ignition sequences and overall system operation. It is important to note that this is a factory OEM component and not a universal replacement, ensuring compatibility and optimal performance with specified Trane and American Standard units.

Trane CNT07941 Control Circuit Board in packaging next to the board itself

Image: The Trane CNT07941 Control Circuit Board, shown both in its original packaging and as a standalone component, highlighting its design and form factor.

2. حفاظت جي ڄاڻ

WARNING: Installation and servicing of HVAC components should only be performed by qualified, experienced technicians. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read and understand these instructions thoroughly before attempting any installation or service.

3. سيٽ اپ ۽ تنصيب

This section provides general guidelines for replacing a furnace control board. Specific steps may vary depending on your furnace model. Always consult your furnace's service manual for detailed instructions.

  1. پاور ڪنيڪشن: Turn off all electrical power to the furnace at the main service panel or circuit breaker. Verify power is off using a voltagاي ميٽر.
  2. رسائي ڪنٽرول بورڊ: Locate and open the furnace's control panel or access door. The control board is typically mounted within this compartment.
  3. دستاويز جي وائرنگ: Before disconnecting any wires, take clear photographs of the existing wiring connections to the old control board. Label each wire and its corresponding terminal on the old board. This is crucial for correct re-installation.
  4. تارون ڌار ڪريو: Carefully disconnect all wires from the old control board. Note any specific connectors or harnesses.
  5. پراڻو بورڊ هٽايو: Unmount the old control board. It may be secured with screws, clips, or standoffs.
  6. نئون بورڊ انسٽال ڪريو: Mount the new Trane CNT07941 control board in the same location as the old one, ensuring it is securely fastened.
  7. وائرنگ ڳنڍڻ: Using your documented photographs and labels, carefully connect all wires to the corresponding terminals on the new control board. Double-check every connection for accuracy and tightness.
  8. محفوظ رسائي پينل: Close and secure the furnace's control panel or access door.
  9. پاور بحال ڪريو: Restore electrical power to the furnace at the main service panel or circuit breaker.
  10. ٽيسٽ آپريشن: Initiate a heating cycle to verify proper operation of the furnace. Observe the ignition sequence and fan operation.
بند ڪرڻ view of the Trane CNT07941 Control Circuit Board, showing various components and connection points.

تصوير: هڪ تفصيلي view of the Trane CNT07941 circuit board, illustrating the layout of its electronic components and terminal blocks for wiring connections.

4. آپريٽنگ اصول

The Trane CNT07941 Control Circuit Board is the central processing unit for your furnace's heating cycle. It receives signals from the thermostat and other safety devices to manage the sequence of operations, including:

The board also incorporates diagnostic features, often indicated by an LED light, to assist in troubleshooting system faults.

5. سار سنڀال

The Trane CNT07941 control board itself requires minimal maintenance. However, regular maintenance of the overall HVAC system is crucial for its longevity and proper function.

6. مسئلا حل ڪرڻ

If your furnace is not operating correctly after installing the Trane CNT07941 control board, or if you suspect a board-related issue, consider the following common troubleshooting steps. Always ensure power is disconnected before inspecting or touching internal components.

عام مسئلا حل ڪرڻ جا منظرنامو
علامتيممڪن سببعمل
Furnace not starting (no fan, no heat)No power to furnace, thermostat issue, loose wiring, tripped safety switch.Check circuit breaker. Ensure thermostat is set to heat and temperature is above ambient. Verify all wiring connections to the board are secure. Check furnace safety switches (e.g., limit switch, rollout switch).
Inducer motor runs, but no ignitionFaulty igniter, clogged pressure switch hose, gas supply issue, flame sensor dirty/faulty.Check if gas valve is open. Inspect igniter for cracks or damage. Clean flame sensor. Check pressure switch hose for blockages.
بلور فين مسلسل هلندو آهيThermostat fan setting, stuck fan relay on board, faulty limit switch.Ensure thermostat fan setting is "Auto". If problem persists, professional diagnosis is recommended.
Error code displayed on board LEDمخصوص سسٽم جي خرابي.Refer to your furnace's service manual for the meaning of the specific flash code and recommended corrective actions.

If troubleshooting steps do not resolve the issue, or if you are uncomfortable performing these checks, it is strongly recommended to contact a certified HVAC technician. Attempting repairs without proper knowledge and tools can be dangerous and may void warranties.

7. وضاحتون

Key specifications for the Trane CNT07941 Control Circuit Board:

Diagram showing the dimensions of the Trane CNT07941 Control Circuit Board, with measurements 4 15/16 inches by 5 15/16 inches.

Image: A technical diagram illustrating the physical dimensions of the Trane CNT07941 circuit board, indicating its length and width for accurate fitment.

لاڳاپيل دستاويز - CNT07941_v220

اڳيview ٽرين ۽ آمريڪي معياري IFC بورڊ جي ناڪامي سروس بليٽن - لازمي طور تي ٻيهر ڪم
مخصوص فرنس ماڊلز ۾ انٽيگريٽيڊ فرنس ڪنٽرول (IFC) بورڊ جي ناڪامين بابت ٽرين ۽ آمريڪن اسٽينڊرڊ کان سرڪاري سروس بليٽن. تفصيل غلطي ڪوڊ 5، متاثر ماڊل، ۽ لازمي ٻيهر ڪم جي هدايتون.
اڳيview ٽرين RTWD/RTUD آر نيوال سروس پروگرام ڪٽ جي انسٽاليشن جون هدايتون
RTWD ۽ RTUD چلرز لاءِ ٽرين رينوال سروس پروگرام ڪٽ جي انسٽاليشن جون هدايتون، حصن جي جڳھ، حفاظتي ڊيڄاريندڙ، ماحولياتي خدشن، ۽ حصن جي خرابين جي تفصيل سان.
اڳيview ٽرين جامع ٿڌي پاڻي جي نظام جي ڊيزائن ڪيٽلاگ
ٽرينر جو جديد ٿڌي پاڻي جي نظامن جي ڊيزائننگ لاءِ جامع ڪيٽلاگ. هي گائيڊ سسٽم جي حصن، جديد ڊيزائن جي اصولن، ترتيبن، ۽ چلرز، کولنگ ٽاورز، پمپس، ۽ ڪنٽرول والوز لاءِ چونڊ معيار جي تفصيل ڏئي ٿو. اهو تجارتي ۽ صنعتي HVAC ايپليڪيشنن ۾ ڪارڪردگي، اعتبار، ۽ قيمت جي اثرائتي حاصل ڪرڻ تي ڌيان ڏئي ٿو، جنهن ۾ ٽريسر چلر پلانٽ ڪنٽرول ۽ ٽرينر ڊيزائن اسسٽ تي بصيرت شامل آهي.
اڳيview آر ٽي ايڇ ڊي چلرز لاءِ ٽرين اي ايف ڊي آر ريٽروفٽ انسٽاليشن جون هدايتون
RTHD چلرز لاءِ ٽرين AFDR ريٽروفٽ ايئر ڪولڊ ايڊاپٽيو فريڪوئنسي ڊرائيو™ لاءِ جامع انسٽاليشن گائيڊ. حفاظت، ماحولياتي حالتن، ماڊل جي تفصيلن، ۽ قابليت رکندڙ اهلڪارن لاءِ قدم بہ قدم انسٽاليشن جي طريقيڪار کي ڍڪي ٿو.
اڳيview ٽرين Ignitor لڳائڻ جون هدايتون KIT03033USA
ٽرين اگنيٽر KIT03033USA لاءِ تفصيلي انسٽاليشن هدايتون، حفاظتي ڊيڄاريندڙ، ماحولياتي خيال، ۽ قابل اهلڪارن لاءِ قدم بہ قدم طريقا شامل آهن.
اڳيview ٽرين ايئر فائي ™ وائرليس ڪميونيڪيشن سينسر (WCS) تڪڙو حوالو گائيڊ
هي گائيڊ ٽرين ايئر-فائي™ وائرليس ڪميونيڪيشن سينسر (WCS) لاءِ تڪڙي حوالي جي معلومات فراهم ڪري ٿو، جنهن ۾ ڪمري جي گرمي پد، سسٽم سيٽنگون، فين جي رفتار، قبضي کي منظم ڪرڻ، ۽ غلطي ڪوڊ کي سمجهڻ جي تفصيل شامل آهي. ان ۾ حفاظتي ڊيڄاريندڙ ۽ بيٽري جي زندگي جا اشارا شامل آهن.