A-iPower SUA4000iED

A-iPower SUA4000iED Dual Fuel Inverter Generator Instruction Manual

Model: SUA4000iED

1. تعارف

This manual provides essential instructions for the safe operation, maintenance, and troubleshooting of your A-iPower SUA4000iED Dual Fuel Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.

2. اهم حفاظتي ڄاڻ

Failure to follow these safety instructions can result in serious injury or death. Always operate the generator in accordance with all local regulations and safety guidelines.

2.1 ڪاربن مونو آڪسائيڊ جو خطرو

  • Generators produce carbon monoxide, an odorless, colorless, and poisonous gas.
  • ڪڏهن به نه operate the generator indoors, in a garage, or in any enclosed space.
  • جنريٽر کي هميشه ٻاهر سٺي هوادار علائقي ۾ هلايو، دريون، درن ۽ وينٽن کان پري.
  • Install battery-operated carbon monoxide alarms in your home or RV.

2.2 باهه جو خطرو

  • Gasoline and propane are highly flammable.
  • ريفيول صرف ان صورت ۾ جڏهن انجڻ بند ۽ ٿڌي هجي.
  • Do not smoke or allow open flames near the generator, especially during refueling.
  • Store fuel in approved containers in a well-ventilated area, away from ignition sources.

2.3 اليڪٽريڪل شاڪ جو خطرو

  • Do not operate the generator in wet conditions or expose it to rain or snow.
  • Ensure all electrical connections are secure and dry.
  • Use only grounded extension cords and appliances.
  • Never connect the generator directly to your home's electrical system without a transfer switch installed by a qualified electrician.

3. جنريٽر جا جزا

Familiarize yourself with the various parts of your A-iPower SUA4000iED generator.

A-iPower SUA4000iED Inverter Generator, front-side view

شڪل 3.1: سامهون واري پاسي view of the A-iPower SUA4000iED Inverter Generator, highlighting the control panel and outlets.

3.1 ڪنٽرول پينل ختمview

The control panel provides access to all operational controls and outlets.

  • مکيه سوئچ: Controls engine operation (OFF, RUN, START).
  • ٻارڻ چونڊيندڙ: Allows selection between Gasoline and Propane (LPG).
  • Low Idle Mode Switch: Engages fuel-saving mode.
  • آئوٽليٽ: Includes 2 NEMA 120V AC 20A Household outlets, 1 NEMA 120V AC 30A L5-30R Locking outlet, and 2 USB ports.
  • سرڪٽ ٽوڙيندڙ: Protects against overload.
  • ڪلاڪ ميٽر: Displays total operating hours for maintenance tracking.
Close-up of the A-iPower generator's control panel with a hand pressing the electric start button.

Figure 3.2: Detail of the control panel, showing the electric start button and various switches.

3.2 Other Key Features

  • Telescoping Handle and Wheels: آسان ٽرانسپورٽ لاء.
  • Oil Fill/Drain: Access points for engine oil.
  • ايئر فلٽر ڪَوَر: For maintenance access.
  • بيٽري جو خانو: Houses the starting battery.

4. سيٽ اپ جون هدايتون

Follow these steps to prepare your generator for first use.

4.1 پيڪنگ ۽ چڪاس

  1. پيڪنگ مان جنريٽر ۽ سڀئي لوازمات احتياط سان هٽايو.
  2. Inspect the generator for any shipping damage. Contact customer support immediately if damage is found.
  3. Verify all included items are present: 30A RV adapter, tool kit, 12V DC charging cables, oil funnel, owner's manual, quick start guide.
Image showing the A-iPower SUA4000iED generator with an overlay listing included accessories: 30A RV Adaptor, Tool Kit, 12V DC Charging Cables, Oil Funnel, Owners Manual, Quick Start Guide.

Figure 4.1: Contents included with the A-iPower SUA4000iED generator.

4.2 انجڻ جو تيل شامل ڪرڻ

The generator is shipped without engine oil. You must add the correct amount and type of oil before starting.

  1. جنريٽر کي ھڪڙي سطح جي مٿاري تي رکو.
  2. تيل ڀرڻ واري ڪيپ/ڊپ اسٽڪ کي ڳوليو.
  3. Using the provided oil funnel, slowly add 10W-30 engine oil until it reaches the upper mark on the dipstick. Do not overfill.
  4. تيل ڀرڻ واري ڪيپ کي محفوظ طور تي تبديل ڪريو.

4.3 بيٽري ڳنڍڻ

The generator includes a battery for electric start. It may require connection before first use.

  1. بيٽري جي ڪمري کي ڳولھيو.
  2. Connect the positive (+) battery cable (red) to the positive (+) terminal and the negative (-) battery cable (black) to the negative (-) terminal. Ensure connections are secure.

4.4 جنريٽر ۾ تيل ڀرڻ

This generator operates on both gasoline and propane (LPG).

4.4.1 گيسولين

  1. پڪ ڪريو ته جنريٽر بند ۽ ٿڌو آهي.
  2. ٻارڻ جي ڪيپ کوليو.
  3. Fill the fuel tank with fresh, unleaded gasoline (minimum 87 octane). Do not overfill. Leave space for fuel expansion.
  4. ايندھن جي ڍڪ کي محفوظ طور تي بند ڪريو.

4.4.2 Propane (LPG)

  1. Connect the propane hose (included) to the generator's propane inlet and to a standard propane tank.
  2. پڪ ڪريو ته سڀئي ڪنيڪشن تنگ آهن ته جيئن ليڪ نه ٿئي.
  3. پروپين ٽينڪ تي والو کي آهستي آهستي کوليو.

5. آپريٽنگ هدايتون

Learn how to start and operate your dual fuel inverter generator.

5.1 جنريٽر شروع ڪرڻ

Ensure the generator is on a level surface, outdoors, and away from any obstructions.

5.1.1 Electric Start (Gasoline)

  1. Ensure the fuel selector is set to 'Gasoline'.
  2. Turn the main switch to the 'START' position. The engine should crank and start.
  3. Once started, release the switch to the 'RUN' position.

5.1.2 Electric Start (Propane)

  1. Ensure the propane tank valve is open and the hose is securely connected.
  2. Set the fuel selector to 'Propane'.
  3. Turn the main switch to the 'START' position. The engine may take a few extra seconds to start on propane.
  4. Once started, release the switch to the 'RUN' position.

5.1.3 ريموٽ شروع

The generator comes with a remote control for convenient starting.

  1. Follow steps 5.1.1 or 5.1.2 to select the desired fuel type.
  2. Ensure the main switch is in the 'RUN' position.
  3. Press the 'START' button on the remote control.

5.2 Low Idle Mode

Engage the 'Low Idle Mode' switch to optimize fuel consumption and reduce noise when power demand is low. The engine speed will automatically adjust to match the load.

A-iPower generator operating with a sound meter displaying 58.0 decibels, indicating quiet operation.

Figure 5.1: The generator's quiet operation, often enhanced by Low Idle Mode.

5.3 بجلي جي لوڊ کي ڳنڍڻ

  1. Once the generator is running stably, plug in your appliances or extension cords into the appropriate outlets.
  2. جنريٽر جي درجه بندي ٿيل هلندڙ واٽ کان وڌيڪ نه ڪريوtagاي (پيٽرول تي 3500W، پروپين تي 3200W).
  3. For RV use, utilize the 30A L5-30R locking outlet with the provided adapter.
A-iPower SUA4000iED generator connected to an RV via an electrical cord, demonstrating its RV-ready capability.

Figure 5.2: Generator connected for RV power.

5.4 متوازي آپريشن

The SUA4000iED is capable of parallel operation with another compatible A-iPower inverter generator to increase total power output. A parallel kit (sold separately) is required.

  1. Refer to the parallel kit's instruction manual for detailed connection procedures.
  2. Ensure both generators are off before connecting the parallel kit.
  3. Start both generators according to their individual starting procedures.
Two A-iPower SUA4000iED generators connected for parallel operation, with cables linking their parallel outlets.

Figure 5.3: Two generators configured for parallel operation.

5.5 جنريٽر بند ڪرڻ

  1. جنريٽر مان سڀ بجليءَ جي لوڊ کي ڌار ڪريو.
  2. جنريٽر کي ڪجهه منٽن لاءِ بغير لوڊ ڪرڻ جي ٿڌو ٿيڻ جي هلڻ ڏيو.
  3. Turn the main switch to the 'OFF' position.
  4. جيڪڏهن پروپين استعمال ڪري رهيا آهيو، ته پروپين ٽينڪ تي والو بند ڪريو.

6. سار سنڀال

باقاعده سار سنڀال بهترين ڪارڪردگي کي يقيني بڻائي ٿي ۽ توهان جي جنريٽر جي زندگي کي وڌائي ٿي.

6.1 سار سنڀال جو شيڊول

خدمت جو سامانپهريون 20 ڪلاڪهر 50 ڪلاڪن ۾ / ساليانوهر 100 ڪلاڪن ۾ / ساليانو
انجڻ جي تيل جي سطح چيڪ ڪريو
انجڻ جو تيل تبديل ڪريو
صاف ايئر فلٽر
اسپارڪ پلگ جو معائنو ڪريو
ايندھن فلٽر چيڪ ڪريو

6.2 انجڻ جو تيل تبديل ڪرڻ

  1. تيل کي گرم ڪرڻ لاءِ انجن کي ڪجهه منٽن لاءِ هلايو، پوءِ ان کي بند ڪريو.
  2. تيل جي ڊرين پلگ هيٺان هڪ ڊرين پين رکو.
  3. Remove the oil drain plug and oil fill cap to allow the oil to drain completely.
  4. Replace the drain plug and refill with the recommended amount and type of new oil (10W-30).
  5. استعمال ٿيل تيل کي ذميواري سان ضايع ڪريو.

6.3 ايئر فلٽر جي صفائي

  1. ايئر فلٽر جي ڍڪ کي هٽايو.
  2. Remove the foam air filter element.
  3. Wash the element in warm, soapy water, rinse, and allow to air dry completely.
  4. Lightly oil the foam element with engine oil, then squeeze out excess oil.
  5. Reinstall the air filter and cover.

6.4 اسپارڪ پلگ جي چڪاس

  1. Remove the spark plug cap and use a spark plug wrench to remove the spark plug.
  2. Inspect the electrode for wear and carbon buildup. Clean or replace as necessary.
  3. Check the spark plug gap and adjust if needed.
  4. اسپارڪ پلگ ۽ ڪيپ کي ٻيهر انسٽال ڪريو.

6.5 بيٽري جي سار سنڀال

To maintain the starting battery, especially during storage:

  • Use a 12V battery tender to keep the battery charged.
  • If storing for extended periods, disconnect the battery or run the generator monthly to recharge it.

7. مسئلا حل ڪرڻ

هي سيڪشن عام مسئلن کي حل ڪري ٿو جيڪي توهان کي پنهنجي جنريٽر سان منهن ڏيڻا پوندا.

7.1 انجن شروع نه ٿيندو

  • ٻارڻ ناهي: Check gasoline level or propane tank connection and valve.
  • Incorrect Fuel Selection: Ensure the fuel selector matches the fuel being used.
  • گھٽ تيل: The generator has a low oil shutdown feature. Check oil level and add if necessary.
  • اسپارڪ پلگ: اسپارڪ پلگ کي گندگي يا نقصان لاءِ چيڪ ڪريو.
  • Battery (Electric Start): Ensure the battery is charged and properly connected. Cold temperatures can affect battery performance.
  • چوڪس: Ensure the choke is in the correct position for starting (usually closed when cold, open when warm).

7.2 ڪابه پاور آئوٽ پُٽ ناهي

  • سرڪٽ برڪر ٽرپ: Check and reset any tripped circuit breakers on the control panel.
  • اوور لوڊ: Reduce the total load connected to the generator.
  • Faulty Cord/Appliance: Test with a different appliance or cord.

7.3 ٻارڻ جو رساو

  • لوز ڪنيڪشن: Check all fuel lines and connections for tightness.
  • Damaged Gasket/Carburetor: If leaks persist, especially from the carburetor area, discontinue use and contact customer support.

8. وضاحتون

Technical details for the A-iPower SUA4000iED Inverter Generator.

خاصيتتفصيل
ماڊلSUA4000iED
انجڻ223cc OHV 4-Stroke
شروعاتي واٽ (پيٽرول)4000W
هلندڙ واٽ (پيٽرول)3500W
شروعاتي واٽ (پروپين)3500W
رننگ واٽس (پروپين)3200W
ٻارڻ جو قسمگيسولين، پروپين
شروعاتي قسمElectric Start, Remote Start
شور جي سطح58 dB (at 25% load)
پيداوار جي ماپ60.45 x 48.77 x 55.88 سينٽي (23.8 x 19.2 x 22 انچ)
وزن56.7 ڪلوگرام (124.7 پائونڊ)
آئوٽليٽ2x 120V AC 20A, 1x 120V AC 30A L5-30R, 2x USB

9. وارنٽي ڄاڻ

A-iPower products are backed by a manufacturer's warranty. Please refer to the warranty card included with your generator or visit the official A-iPower webسڀ کان وڌيڪ جديد ۽ تفصيلي وارنٽي شرطن ۽ ضابطن لاءِ سائيٽ. وارنٽي دعوائن لاءِ خريداري جو ثبوت رکو.

10. ڪسٽمر سپورٽ

For technical assistance, parts, or warranty inquiries, please contact A-iPower customer support:

  • Webسائيٽ: Visit the official A-iPower webسوالن ۽ سپورٽ وسيلن لاءِ سائيٽ.
  • فون: Refer to your owner's manual or the A-iPower webموجوده رابطي نمبرن لاءِ سائيٽ.
  • اي ميل: Use the contact form or email address provided on the A-iPower webسائيٽ.

When contacting support, please have your generator's model number (SUA4000iED) and serial number ready.

لاڳاپيل دستاويز - SUA4000iED

اڳيview A-iPower SUA5800iED ڊول فيول انورٽر جنريٽر: خاصيتون، وضاحتون، ۽ ٽيڪنالاجي
تفصيلي ختمview A-iPower SUA5800iED ڊول فيول انورٽر جنريٽر، جنهن ۾ اهم خاصيتون، ٽيڪنيڪل وضاحتون، ڪنٽرول پينل فنڪشن، ۽ فيول سينس ٽيڪنالاجي شامل آهن. ان جي 5800 شروعاتي واٽ، 224cc انجن، ۽ وڌايل رن ٽائم صلاحيتن بابت سکو.
اڳيview A-iPower GXS4300iDC Generator Quick Start Guide - Model 1491001
Concise quick start guide for the A-iPower GXS4300iDC dual fuel inverter generator. Learn how to unpack, add fuel and oil, start the engine, shut down, store, and switch between gasoline and propane (LPG). Includes essential safety warnings regarding carbon monoxide.
اڳيview A-iPower XOS2300iD 2300 Watt Dual Fuel Inverter Generator
Specifications and features for the A-iPower XOS2300iD, a 2300 Watt Dual Fuel Inverter Generator with Fuel Sense Technology, EPA certified, lightweight design, and clean power output.
اڳيview A-iPower SUA2301iD Portable Generator Owner's Manual
Comprehensive owner's manual for the A-iPower SUA2301iD portable generator. Covers safety precautions, operation, maintenance, troubleshooting, and warranty information for this dual-fuel (gasoline/propane) generator.
اڳيview A-iPower SUA12000EDP Portable Generator Owner's Manual: Safety, Operation, and Maintenance Guide
Comprehensive owner's manual for the A-iPower SUA12000EDP portable generator. Learn about safe operation, setup, maintenance, troubleshooting, and specifications for reliable power generation. Features dual fuel capability (gasoline/propane) and critical carbon monoxide safety information.
اڳيview A-iPower SUA2000iD 2000 Watt Dual Fuel Inverter Generator Specifications and Features
Detailed specifications and features for the A-iPower SUA2000iD 2000 Watt Dual Fuel Inverter Generator, including power output, fuel types, run time, noise level, and technical data.