This manual provides essential information for the proper installation, operation, and maintenance of the NOTIFIER FS-OSI-RI Adressable Beam Detector. The FS-OSI-RI is a sophisticated fire safety device designed to detect smoke over large areas by projecting and receiving an infrared beam. It is an integral component of an addressable fire alarm system, providing reliable early warning capabilities.

2. حفاظت جي ڄاڻ

Read all instructions carefully before installation and operation. This device must be installed by qualified personnel in accordance with all local and national electrical and fire codes. Disconnect power before servicing. Failure to follow these instructions may result in property damage, injury, or death. Regular testing and maintenance are crucial for optimal performance.

3. سيٽ اپ

3.1 کولڻ

Carefully remove the beam detector and its components from the packaging. Inspect all items for any signs of damage. Report any damage to your supplier immediately. Retain packaging for future transport or storage.

3.2 چڙهڻ

The FS-OSI-RI consists of a transmitter/receiver unit and a reflector. Mount the transmitter/receiver unit and the reflector on a stable surface, ensuring they are aligned and within the specified operating distance. Refer to the detailed mounting diagrams provided in the separate installation guide for precise placement and alignment procedures. Ensure the mounting location is free from obstructions and excessive vibration.

NOTIFIER FS-OSI-RI Adressable Beam Detector unit

Image 1: The NOTIFIER FS-OSI-RI Adressable Beam Detector unit. This image shows the main component of the beam detector, which houses both the infrared transmitter and receiver. It is typically mounted on a wall or ceiling, facing the reflector.

3.3 وائرنگ

Connect the detector to the addressable fire alarm control panel (FACP) using appropriate wiring methods as specified in the FACP manual and local codes. Ensure correct polarity and secure all connections. The device operates on a low-voltage power source provided by the FACP.

3.4 Initial Power-Up and Addressing

After all wiring is complete and verified, apply power to the FACP. The detector will perform a self-test. Set the unique address for the FS-OSI-RI using the addressing mechanism on the device, following the FACP's programming instructions. Proper addressing is critical for the FACP to identify the detector's location and status.

4. آپريٽنگ

4.1 بنيادي ڪارڪردگي

The FS-OSI-RI continuously monitors the infrared beam path between its transmitter/receiver unit and the reflector. When smoke enters the beam path, it obscures the beam, causing a reduction in the received signal. If the signal reduction exceeds a pre-set threshold for a specified duration, the detector will signal an alarm condition to the FACP.

4.2 اسٽيٽس جا اشارا

The detector features LED indicators to communicate its operational status:

  • گرين لائيٽ: عام آپريشن جي نشاندهي ڪري ٿو.
  • ڳاڙهو لال هڪ الارم حالت کي اشارو ڪري ٿو.
  • پيلو LED: Indicates a trouble condition (e.g., beam blockage, misalignment, fault).

4.3 سسٽم انٽيگريشن

As an addressable device, the FS-OSI-RI communicates its status directly to the FACP, allowing for precise identification of the alarm or trouble source. The FACP will then initiate appropriate responses, such as activating alarms, notifying emergency services, or displaying the event location.

5. سار سنڀال

5.1 صفائي

Periodically inspect the detector's lens and the reflector for dust, dirt, or other obstructions. Clean these surfaces using a soft, lint-free cloth. For stubborn dirt, a mild, non-abrasive cleaning solution may be used, applied to the cloth, not directly to the device. Ensure the device is powered down before cleaning.

5.2 Testing Procedures

Regular functional testing is essential. Perform tests in accordance with NFPA 72 and local authority having jurisdiction (AHJ) requirements. Testing typically involves:

  • Smoke Obscuration Test: Introduce an approved test smoke into the beam path to verify alarm activation.
  • ترتيب جي چڪاس: Verify proper beam alignment using the detector's alignment indicators or a dedicated alignment tool.
  • حساسيت ٽيسٽ: If applicable, verify the detector's sensitivity settings are within acceptable ranges.

5.3 بيٽري مٽائڻ

While the primary power source is typically wired, some systems may incorporate backup batteries. If your system includes a battery backup for the detector or its associated control module, ensure batteries are replaced according to the manufacturer's recommendations or when a low battery trouble signal is indicated by the FACP.

6. مسئلا حل ڪرڻ

Refer to the FACP manual for specific trouble codes and detailed troubleshooting steps. Below are general troubleshooting guidelines:

  • غلط الارم: Check for environmental factors such as dust, steam, insects, or direct sunlight interfering with the beam path. Verify proper alignment and cleanliness of the lens and reflector.
  • ڪابه سڃاڻپ ناهي: Ensure the detector is powered, correctly addressed, and properly aligned. Check for complete beam obstruction or damage to the unit/reflector.
  • Trouble Signal (Yellow LED): This often indicates a beam blockage, misalignment, or a fault within the unit. Re-align the beam, clean the optics, and check wiring connections. If the issue persists, contact technical support.
  • رابطي جون غلطيون: Verify wiring integrity between the detector and the FACP. Check the detector's address setting.

7. وضاحتون

خاصيتتفصيل
ماڊل نمبرFS OSI RI
حصو نمبرNFSOSIRI
ٺاهيندڙاطلاع ڏيڻ وارو
طاقت جو ذريعوBattery Powered (typically system-level backup or low-voltage from FACP)
الارم جو قسمAudible (via FACP)
اندازحفاظت
يو پي سي742779301956

8. وارنٽي ۽ سپورٽ

For warranty information, please refer to the documentation provided with your purchase or contact your authorized Notifier distributor. Technical support is available through your installer or Notifier's official support channels. Do not attempt to repair the device yourself, as this may void the warranty and compromise safety.

لاڳاپيل دستاويز - FS OSI RI

اڳيview نوٽيفائر DHX-501 ايئر ڊڪٽ اسموڪ ڊيٽيڪٽر انسٽاليشن ۽ سار سنڀال جو دستور
هي دستورالعمل نوٽيفائر DHX-501 انٽيليجنٽ ايئر ڊڪٽ اسموڪ ڊيٽيڪٽر هائوسنگ لاءِ تفصيلي انسٽاليشن، وائرنگ، ٽيسٽنگ، ۽ سار سنڀال جا طريقا مهيا ڪري ٿو. اهو نوٽيفائر CPX-551 ۽ SDX-551 ڊيٽيڪٽر هيڊز سان استعمال لاءِ عام وضاحتون، جزوي فهرستون، حفاظتي ڊيڄاريندڙ، قدم بہ قدم تنصيب، وقتي سار سنڀال، ۽ وضاحتون شامل ڪري ٿو.
اڳيview OSI-R-SS ۽ OSI-RA-SS روايتي سنگل اينڊڊ ريفليڪٽو اميجنگ بيم اسموڪ ڊيٽيڪٽر
نوٽيفائر OSI-R-SS ۽ OSI-RA-SS ترقي يافته روايتي سنگل اينڊڊ ريفليڪٽو اميجنگ بيم اسموڪ ڊيٽيڪٽر آهن جيڪي وڏين ڇتين وارن کليل علائقن لاءِ ٺهيل آهن. اهي بديه ترتيب، عمارت جي حرڪت ۽ سج جي روشني جي مزاحمت، خودڪار حساسيت سيٽنگون، ۽ ڊرفٽ معاوضو پيش ڪن ٿا، انهن کي گودامن، ايٽريم ۽ راندين جي ميدانن لاءِ مثالي بڻائين ٿا.
اڳيview نوٽيفائر NFS-320 انٽيليجنٽ ايڊريس ايبل فائر الارم سسٽم ڊيٽا شيٽ
نوٽيفائر NFS-320 انٽيليجنٽ ايڊريس ايبل فائر الارم سسٽم لاءِ جامع ڊيٽا شيٽ، ان جي خاصيتن، انٽيليجنٽ سينسنگ صلاحيتن، فليش اسڪين پروٽوڪول، سسٽم جي وضاحتن، مطابقت رکندڙ ڊوائيسز، ۽ ايجنسي جي منظورين جي تفصيل سان.
اڳيview نوٽيفائر 30-3003 ڌماڪي جو ثبوت دونھين جي چڪاس ڪندڙ: خاصيتون ۽ وضاحتون
خطرناڪ صنعتي ماحول لاءِ ٺهيل نوٽيفائر 30-3003 ايڪسپلوزن پروف اسموڪ ڊيٽيڪٽر جون خاصيتون، ايپليڪيشنون ۽ ٽيڪنيڪل وضاحتون دريافت ڪريو.
اڳيview Notifier Intelligent VESDA-E VEU SLC with VESDAnet Detectors | Honeywell
Comprehensive technical data sheet for Notifier Intelligent VESDA-E VEU SLC with VESDAnet detectors (VEU-A00-NTF-VN, VEU-A10-NTF-VN). Learn about Flair detection technology, UL 268 7th Edition compliance, connectivity, modes of operation, specifications, and integration with Honeywell fire alarm control panels.
اڳيview نوٽيفائر AFP-2800 فائر الارم پينل: آپريٽرز، انسٽاليشن، ۽ پروگرامنگ مينوئل
نوٽيفائر AFP-2800 فائر الارم پينل لاءِ جامع دستور، جيڪو آپريٽرز جي گائيڊ، انسٽاليشن جي طريقيڪار، پروگرامنگ، سسٽم جي وضاحت، وضاحتون، ۽ خرابي جي حل کي ڍڪيندو آهي. سسٽم سيٽ اپ ۽ سار سنڀال لاءِ ضروري آهي.