1. تعارف
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 system. Please read this manual thoroughly before attempting to install or operate the unit to ensure safe and efficient use.
The Solaxx CLGE40 is designed to provide efficient water treatment for pools up to 40,000 gallons, integrating multiple functions into a single, compact unit.
2. حفاظت جي ڄاڻ
Always observe the following safety precautions to reduce the risk of injury, electric shock, fire, or damage to the unit.
- برقي حفاظت: Ensure the unit is connected to a properly grounded outlet. Do not operate with damaged cords or plugs. Disconnect power before servicing.
- ڪيميائي سنڀال: Follow all manufacturer's instructions for handling pool chemicals. Avoid direct contact with skin and eyes.
- تنصيب: Installation must be performed by a qualified professional in accordance with all local and national electrical and plumbing codes.
- پاڻي جي معيار: Maintain proper water chemistry as specified in this manual to ensure optimal performance and longevity of the unit.
- ٻار ۽ پالتو جانور: آپريشن ۽ سار سنڀال دوران ٻارن ۽ پالتو جانورن کي يونٽ کان پري رکو.
3. پراڊڪٽ ختمview

شڪل 3.1: سامهون view of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 unit. This image displays the main body of the unit, including the control panel with various indicators and buttons, and the transparent cell housing below.

شڪل 3.2: زاويه view of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 unit. This perspective provides a clearer view of the transparent cell, which allows for visual inspection, and the plumbing connection points on either side.
The CLGE40 system integrates a salt chlorine generator with advanced control features. Key components include the control unit, the electrolytic cell, and various sensors for optimal performance.
4. سيٽ اپ ۽ تنصيب
4.1 قبل از انسٽاليشن چيڪ لسٽ
- پڪ ڪريو ته سڀئي جزا موجود آهن ۽ انهن کي نقصان نه پهتو آهي.
- Ensure adequate space for installation and maintenance.
- Confirm power supply meets unit requirements (refer to specifications).
- Have necessary plumbing tools and materials ready.
4.2 پلمبنگ جي انسٽاليشن
- Select an appropriate location in the return line after the filter and heater.
- Cut the existing PVC pipe and install the provided unions.
- Securely attach the electrolytic cell to the unions, ensuring proper flow direction as indicated on the cell.
- Apply PVC cement to all connections for a watertight seal. Allow adequate curing time.
4.3 برقي ڪنيڪشن
- پڪ ڪريو ته سرڪٽ بريڪر تي بجلي بند آهي.
- Connect the control unit to a dedicated, grounded electrical outlet or circuit as per local electrical codes.
- Connect the cell cable to the control unit.
- Do not restore power until all connections are secure and the system is filled with water.
5. آپريٽنگ هدايتون
5.1 شروعاتي شروعات
- Ensure pool water chemistry is balanced (pH, alkalinity, calcium hardness).
- Add pool salt to achieve the recommended salinity level (typically 3000-3500 ppm). Allow salt to dissolve completely.
- حوض پمپ تي موڙ.
- Restore power to the Solaxx CLGE40 unit.
- Press the "ON/OFF" button to activate the unit.
5.2 Adjusting Chlorine Output
The unit features an adjustable output level to control chlorine production. Use the "+" and "-" buttons on the control panel to increase or decrease the output percentage. Monitor your pool's free chlorine level and adjust as needed to maintain desired sanitation.
5.3 اشارو روشنيون
- آن/بند: طاقت جي حالت کي ظاهر ڪري ٿو.
- پيداوار: Bar graph showing current chlorine production level.
- گھٽ لوڻ: Illuminates when salt level is below optimal. Add salt.
- ڪوبه وهڪرو: Indicates insufficient water flow through the cell. Check pump and plumbing.
- ٿڌو پاڻي: Illuminates if water temperature is too low for efficient operation.
- CLEAN CELL: Indicates the cell requires cleaning.
- CELL LIFE LOW: Indicates the electrolytic cell is nearing the end of its lifespan and may need replacement soon.
6. سار سنڀال
6.1 سيل جي صفائي
The electrolytic cell may accumulate scale deposits over time, reducing efficiency. The "CLEAN CELL" indicator will illuminate when cleaning is required.
- Turn off the unit and pool pump, and disconnect power.
- Remove the electrolytic cell from the plumbing.
- Prepare a cleaning solution of 1 part muriatic acid to 4 parts water in a plastic container. Always add acid to water, never water to acid.
- Submerge the cell plates in the solution, ensuring the electrical connections remain dry.
- Allow to soak until bubbling stops (typically 5-15 minutes). Do not over-soak.
- Rinse the cell thoroughly with fresh water.
- Reinstall the cell and restore power.
6.2 سياري ڪرڻ
In areas subject to freezing temperatures, the unit must be properly winterized to prevent damage.
- يونٽ کي بجلي بند ڪريو.
- Drain all water from the electrolytic cell and plumbing lines connected to the unit.
- Remove the cell and store it in a dry, temperature-controlled environment.
7. مسئلا حل ڪرڻ
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| "LOW SALT" indicator on | Low salt level in pool water. | Test salt level and add salt as needed. Allow time for dissolution. |
| "NO FLOW" indicator on | Insufficient water flow through cell. | Check pool pump operation, filter cleanliness, and ensure valves are open. |
| "CLEAN CELL" indicator on | Scale buildup on cell plates. | Clean the electrolytic cell as per Section 6.1. |
| Low chlorine output | Low salt, dirty cell, low water temperature, or incorrect output setting. | Check salt level, clean cell, ensure water temperature is adequate, increase output setting. |
| يونٽ پاور نه ٿي رهيو آهي | No power supply, tripped breaker, or faulty connection. | Check power outlet, reset circuit breaker, ensure all electrical connections are secure. |
8. وضاحتون
- ماڊل: CLGE40 Resilience E Series
- Maximum Pool Size: 40,000 گيلن
- ٺاهيندڙ: سولڪسڪس
- پيڪيج جي ماپ: 12 x 12 x 8 انچ
- ASIN: B0B96WPR34
- Recommended Salt Level: 3000-3500 پي ايم پي
نوٽ: وضاحت بغير اطلاع جي تبديلي سان ٿي سگھي ٿي.
9. وارنٽي ۽ سپورٽ
For warranty information, please refer to the warranty card included with your product or visit the official Solaxx webسائيٽ. وارنٽي دعوائن لاءِ خريداري جو ثبوت رکو.
For technical support, troubleshooting assistance, or to order replacement parts, please contact Solaxx Customer Service:
- Webسائيٽ: www.solaxx.com
When contacting support, please have your product model number (CLGE40) and serial number ready.