1. تعارف
This manual provides comprehensive instructions for the safe and effective installation, operation, and maintenance of the Eaton B-line Series B422-1 1/2AL Right Angle Beam Clamp. This aluminum clamp is designed for securing pipes or conduits to structural beams at a right angle, offering a robust connection with a specified load capacity.
Please read this manual thoroughly before installation and retain it for future reference. Adherence to these instructions will ensure proper function and safety.
2. حفاظت جي ڄاڻ
WARNING: Failure to follow these safety instructions may result in property damage, serious injury, or death.
- انسٽاليشن دوران هميشه مناسب ذاتي حفاظتي سامان (PPE) پائڻ، جنهن ۾ حفاظتي چشما ۽ دستانا شامل آهن.
- Ensure the structural beam and the pipe/conduit are capable of supporting the combined weight of the clamp, attached items, and any potential loads.
- Do not exceed the maximum rated load capacity of 500 lbs for this clamp.
- Verify that all bolts and nuts are securely tightened to the manufacturer's recommended torque specifications (if available, otherwise ensure firm tightness without over-tightening).
- cl جي چڪاس ڪريوamp and surrounding structure regularly for signs of wear, corrosion, or damage. Replace damaged components immediately.
- Installation should be performed by qualified personnel familiar with local building codes and safety regulations.
3. پيداوار جا حصا
The Eaton B-line Series B422-1 1/2AL Right Angle Beam Clamp typically consists of the following components:
- مکيه clamp body (aluminum)
- U-bolt or similar pipe-securing mechanism
- Mounting bolts and nuts (quantity as required for secure fastening)

شڪل 1: Illustration of the Eaton B422-1 1/2AL Right Angle Beam Clamp in an installed configuration.
This illustration demonstrates the correct installation of the Eaton B422-1 1/2AL Right Angle Beam Clamp. It shows the clamp securing a cylindrical pipe to the flange of a structural beam using two bolts and nuts. The clamp body is positioned over the beam flange, and the pipe is cradled by the U-shaped portion of the clamp, secured by the bolts.
4. سيٽ اپ ۽ تنصيب
- چڙهڻ جي جڳھ جي سڃاڻپ ڪريو: Select a suitable structural beam that can safely support the intended load. Ensure the beam flange is compatible with the clampجي ڊيزائن.
- پوزيشن Clamp: Place the main body of the B422-1 1/2AL clamp over the edge of the structural beam's flange. The curved portion designed to hold the pipe should face downwards.
- Insert Pipe/Conduit: Carefully position the 1 1/2-inch pipe or conduit into the U-shaped cradle of the clamp.
- محفوظ فاسٽنرز: Insert the provided bolts through the clamp body and the pipe-securing mechanism. Thread the nuts onto the bolts.
- ڪنيڪشن مضبوط ڪريو: Using appropriate tools, gradually tighten the nuts evenly until the clamp firmly grips both the beam and the pipe. Avoid over-tightening, which can damage the clamp or the pipe. Ensure the clamp is stable and does not wobble.
- آخري معائنو: Visually inspect the installed clamp to confirm it is properly seated, all fasteners are tight, and the pipe is securely held.
5. آپريٽنگ هدايتون
The Eaton B422-1 1/2AL beam clamp is a static support device. Its "operation" primarily involves ensuring it remains securely installed and within its load limits.
- لوڊ گنجائش: cl جي تابع نه ڪريوamp to loads exceeding 500 lbs. This rating includes the weight of the pipe/conduit and any contents or attached equipment.
- متحرڪ لوڊ: هن ڪلamp is designed for static loads. Avoid applications involving significant vibration, shock, or dynamic forces unless specifically engineered for such conditions.
- ماحولياتي خيالات: cl کي يقيني بڻايو وڃيamp is used in environments compatible with aluminum construction. Avoid exposure to corrosive agents that could compromise material integrity.
6. سار سنڀال
Regular maintenance ensures the longevity and safety of the beam clamp.
- وقتي معائنو: Conduct visual inspections at least annually, or more frequently in harsh environments or high-stress applications. Check for:
- لوز فاسٽنرز.
- Signs of corrosion, cracks, or deformation on the clamp body or fasteners.
- Damage to the pipe or beam at the clampنقطي.
- بندن کي مضبوط ڪريو: Re-tighten any loose bolts and nuts to ensure secure attachment.
- صفائي: ڪل صاف ڪريوamp as needed to remove dirt, dust, or debris that could obscure damage or contribute to corrosion.
- متبادل: If any part of the clamp shows significant wear, damage, or corrosion, replace the entire clamp assembly. Do not attempt to repair damaged clamps.
7. مسئلا حل ڪرڻ
This section addresses common issues that may arise with beam clamp تنصيب
- Clamp is Loose:
- سبب: Fasteners not tightened sufficiently or have loosened over time.
- حل: Re-tighten all bolts and nuts securely. If loosening persists, consider using thread-locking compound (if compatible with materials and environment) or consult a professional.
- Pipe/Conduit Slipping:
- سبب: ڪافي clamping force, incorrect pipe size, or excessive load.
- حل: Ensure fasteners are tight. Verify the pipe diameter is 1 1/2-inch for optimal fit. Reduce the load if it exceeds the clamp's capacity.
- Visible Damage to Clamp:
- سبب: Overloading, impact, or material fatigue.
- حل: Immediately remove the clamp from service and replace it with a new, undamaged unit. Do not use damaged clamps.
8. وضاحتون
| وصف | تفصيل |
|---|---|
| ٺاهيندڙ | Eaton Electrical |
| ماڊل نمبر | B422-1 1/2AL |
| حصو نمبر | B422-1 1/2AL |
| مواد | المونيم |
| Pipe/Conduit Size Compatibility | 1 1/2 انچ |
| وڌ ۾ وڌ درجه بندي لوڊ | 500 پائونڊ |
| حفاظتي فيڪٽر | 5 |
| شيون پيڪيج مقدار | 1 |
9. سپورٽ ۽ رابطي جي معلومات
For technical assistance, product inquiries, or to report issues, please contact Eaton Electrical customer support. Refer to the official Eaton website for the most current contact details and additional product resources.
Eaton Electrical Official Webسائيٽ: www.eaton.com
Please note that product specifications and information are subject to change without notice. Always refer to the latest documentation provided by the manufacturer.