1. تعارف
This manual provides detailed instructions for the safe and efficient operation of your Albott 9000 BTU Mini Split Air Conditioner Heat Pump. This inverter ductless AC system offers cooling, heating, dehumidifying, and fan modes, designed for spaces up to 450 sq. ft. It features energy-efficient operation with an 18.5 SEER2 rating and includes a self-cleaning function for easy maintenance.

Figure 1: Albott 9000 BTU Mini Split Air Conditioner Heat Pump and included accessories.
2. اهم حفاظتي ڄاڻ
WARNING: Risk of Fire. Flammable Refrigerant Used. To Be Repaired ONLY By Trained Service Personnel. Do Not Puncture Refrigerant Tubing. Dispose Of Properly In Accordance With Federal Or Local Regulations.
- Installation and servicing of this equipment should only be performed by qualified, licensed HVAC technicians.
- برقي جھٽڪو کي روڪڻ لاءِ مناسب گرائونڊنگ کي يقيني بڻايو وڃي.
- Do not install or operate the air conditioner until the power is off for at least five minutes.
- مناسب هوا جي وهڪري کي يقيني بڻائڻ لاءِ ٻاهرين يونٽ جي چوڌاري علائقي کي رڪاوٽن کان پاڪ رکو.
- Avoid installing near heat sources, steam sources, or areas with flammable/explosive gases.
3. دٻي ۾ ڇا آهي
Your Albott Mini Split Air Conditioner package includes the following components:
- اندروني يونٽ
- ٻاهرين يونٽ
- ھدايت وارو دستور
- ريموٽ ڪنٽرول
- بيٽريون (الڪائن)
- Hanging plate for the indoor unit
- Drain pipe for the indoor unit
- Installation dimension drawing template
- 14.76 Ft communication wires
- ڀت جي آستين
- پوٽي
- Copper connection pipe - air pipe
- Copper connection pipe - liquid pipe
- 8.2 Ft power cord
- ٽيپ

Figure 2: All components included in the Albott Mini Split Air Conditioner package.
4. سيٽ اپ ۽ تنصيب
Proper installation is crucial for optimal performance and safety. It is recommended that installation be performed by a licensed professional.
4.1 قبل از انسٽاليشن چيڪ
- Ensure the installation location for the indoor unit is hard, flat, and firm to avoid vibration and noise.
- Maintain adequate clearance around both indoor and outdoor units for proper airflow. Refer to the dimension drawing for specific clearances.
- Avoid installing near heat sources, steam sources, or in areas with smoke, oil, flammable, or corrosive gases.

Figure 3: Recommended clearances for indoor unit installation.
4.2 اندروني يونٽ جي انسٽاليشن
- Remove the mounting bracket from the back of the indoor unit.
- Use the provided paper pattern/template to identify the exact location for drilling holes for the mounting bracket and piping.
- Drill screw holes in the corresponding positions and insert expansion tubes.
- Securely mount the bracket on the wall using expansion screws.
- Drill a wall hole for the refrigerant pipes, ensuring it is inclined outward by 5-10 degrees with a diameter of 60-80mm. Use an anti-dust bag to collect debris.
- Confirm the direction for placing the air conditioning ducts and remove the knock-out panel with a knife, removing any burrs to prevent damage to the drain pipe.
- Pass the communication cable through the hole on the back of the indoor unit and connect the wires to the terminal board according to the color-coded wiring diagram. Secure the wires with the fixing plate.
- Connect the drain hose to the water outlet pipe, ensuring a tight fit.
- Line up all wires and pipes neatly, wrap them together with plastic tapes, and pass them through the wall hole.
- Hang the indoor unit on the mounting plate, ensuring it clicks firmly into place.
- Use pipe protection rings and putty to seal the wall hole around the pipes.
Video 1: Detailed installation guide for the split air conditioner, including indoor unit setup and wiring.
4.3 آئوٽ ڊور يونٽ جي انسٽاليشن
- Place the outdoor unit in a suitable location, either on a wall bracket (purchased separately) or directly on the ground. Ensure the location is firm and flat to prevent vibration and noise.
- Maintain adequate clearance around the outdoor unit. Refer to the dimension drawing for specific clearances.
- Connect the two refrigerant pipes (gas and liquid) to the outdoor unit, ensuring the joints fit snugly and are tightened with a wrench.
- Remove the electrical box cover by unscrewing the three screws.
- Pass the power cable wires through the cover hole (usually the right-hand hole) and fix the wires to the terminal board according to the wiring diagram. Secure the fixing plate.
Video 2: Detailed installation guide for the split air conditioner, including outdoor unit setup and wiring.
4.4 Vacuuming and Refrigerant Release
- Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram.
- Vacuumize the system for at least 15 minutes, ensuring the pressure gauge value is ≤ -0.1MPa (-76cmHg / 500µm).
- Maintain the pressure for 3-5 minutes after vacuumizing. The pressure springback should be ≤ 0.05MPa.
- Open the 1/4 liquid valve and remove the charging hose.
- Using an Allen wrench, open all the liquid valves and gas valves. Finally, retighten the three caps.
Video 3: Detailed installation guide for the split air conditioner, including vacuuming and refrigerant release.
5. آپريٽنگ هدايتون
Your Albott Mini Split system offers multiple modes and features for optimal comfort control.
5.1 ريموٽ ڪنٽرول افعال
The remote control allows you to adjust settings from up to 30 feet away. It features buttons for mode selection, temperature adjustment, fan speed, and special functions.

Figure 4: Remote control for Albott Mini Split Air Conditioner.
5.2 آپريٽنگ موڊس
- کولنگ موڊ: Provides efficient cooling to maintain desired room temperature.
- گرمي موڊ: Functions as a heat pump to warm your space.
- ڊيهوميڊائيفائنگ موڊ: هوا ۾ نمي جي سطح گھٽائي ٿي.
- پکي جي موڊ ٿڌي يا گرم ڪرڻ کان سواءِ هوا کي گردش ڪري ٿو.
- خودڪار موڊ: Automatically selects the appropriate mode based on the set temperature and ambient conditions.
- سمهڻ جو طريقو: توانائي بچائيندي آرامده ننڊ لاءِ گرمي پد ۽ پنکڙي جي رفتار کي ترتيب ڏئي ٿو.
- ايڪو موڊ: Optimizes energy consumption for cost savings.

Figure 5: The 4-in-1 functionality of the Albott Mini Split system.
5.3 گرمي پد ۽ فين جي رفتار جي ترتيب
- Adjust temperature settings between 60°F and 90°F using the remote control.
- Select from Low, Mid, High, or Turbo fan speeds to control airflow intensity.
- Utilize the 4-way swing function for personalized airflow direction.

Figure 6: 4D Adjustable Airflow for optimal comfort.
6. سار سنڀال
Regular maintenance ensures the longevity and efficiency of your unit.
6.1 خود صفائي جو ڪم
The unit features a 135°F self-cleaning function to help remove dust buildup. A reminder will appear every 500 hours of operation to activate the 30-minute self-cleaning cycle.

Figure 7: Self-cleaning technology for hassle-free maintenance.
6.2 هٽائڻ وارو مٽي فلٽر
The detachable dust filter can be easily removed for quick and hassle-free cleaning. Regular cleaning of the filter helps trap dust and particles, ensuring fresher air circulation and enhanced durability of internal components.

Figure 8: Detachable dust filter for easy cleaning.
7. وضاحتون
| خاصيت | تفصيل |
|---|---|
| برانڊ | Albott |
| ماڊل ڄاڻ | SAC011 |
| ٿڌي طاقت | 9000 برطانوي حرارتي يونٽ |
| گرمائش جي گنجائش | 9200 BTU |
| ڪوريج ايريا | 450 اسڪوائر فوٽ تائين |
| موسمي توانائي جي ڪارڪردگي جو تناسب (SEER2) | 18.5 |
| جلدtage | 220 وولٽ |
| واتtage | 800 واٽ |
| شور جي سطح | 29 ڊيسيبل |
| پيداوار جي ماپ | 29.92"ڊي x 11.61"ڊي x 7.9"ايڇ |
| خاص خاصيتون | 4 Way Swing, Auto Clean, Dust Filter, Fast Cooling, Heating & Cooling Function |

Figure 9: Product dimensions and technical specifications.
8. وارنٽي ۽ سپورٽ
For any product inquiries, technical support, or warranty claims, please contact Albott customer service. A customer review mentioned that Albott provides prompt responses and resolutions. You can reach them at: support@albott-us.com.