1. تعارف
The Vertiv Liebert IntelliSlot RDU120 Network Card is an advanced remote monitoring adapter designed to enhance the management capabilities of Vertiv products. This card facilitates secure and flexible communication, enabling real-time data access and system status monitoring for critical infrastructure.
1.1 پيداوار ختمview
The RDU120 provides web access and data transmission via industry-standard protocols such as SNMP, Modbus, and BACNet. It supports environmental monitoring through compatible Geist Sensors for parameters like temperature, humidity, leak detection, and contact closures. Its UL2900-1 cybersecurity certification ensures secure online communication and data integrity.
1.2 اهم خاصيتون
- UL2900-1 Cybersecurity Certified: Ensures secure online communication.
- Secure Boot with Hardware Trust Anchor: Prevents unauthorized software tampڀڙڪائڻ.
- Flexible Communication: Supports SNMP, Modbus, and BACnet protocols.
- Standard RESTful API Support: Facilitates easy configuration and updates.
- 1 جي بي ايٿرنيٽ: Compatible with modern network environments and web برائوزر.
- ماحولياتي نگراني: Supports Geist Sensors for various environmental parameters.
2. حفاظت جي ڄاڻ
Please read and understand all safety instructions before installing or operating the Vertiv Liebert IntelliSlot RDU120 Network Card. Failure to follow these instructions may result in injury, damage to the product, or voiding of the warranty.
- Ensure the host device is powered off and disconnected from the power source before installation.
- Handle the network card by its edges to avoid touching electronic components.
- Use appropriate electrostatic discharge (ESD) precautions when handling the card.
- Do not expose the card to moisture or extreme temperatures.
- Only use accessories and cables approved by Vertiv.
3. پيڪيج مواد
پيڪيج کولڻ وقت پڪ ڪريو ته سڀئي شيون موجود آهن ۽ انهن کي ڪو نقصان نه پهتو آهي:
- Vertiv Liebert IntelliSlot RDU120 Network Card
- تڪڙي شروعات جي ھدايت (جيڪڏهن قابل اطلاق هجي)
- چڙهڻ وارا اسڪرو (جيڪڏهن قابل اطلاق هجي)
جيڪڏهن ڪا به شيءِ غائب يا خراب آهي، ته فوري طور تي پنهنجي سپلائر سان رابطو ڪريو.
4. پراڊڪٽ ختمview
Familiarize yourself with the physical components and ports of the RDU120 Network Card.

شڪل 4.1: مجموعي طور view of the RDU120 Network Card, displaying the circuit board and connectors.

شڪل 4.2: زاويه view of the RDU120, showing the front panel and card profile.

شڪل 4.3: تفصيلي view of the RDU120 front panel, indicating port labels.

شڪل 4.4: پاسي view of the RDU120, showing its form factor and mounting bracket.
4.1 Front Panel Ports and Indicators
- ايٿرنيٽ پورٽ (RJ45): For 1 Gb network connectivity.
- USB پورٽ: For local configuration or firmware updates.
- RS-485/232 Ports: For serial communication with compatible devices.
- Activity/Link LEDs: Indicate network activity and connection status.
5. سيٽ اپ
5.1 تنصيب جا مرحلا
- Power Down Host Device: Ensure the Vertiv equipment where the RDU120 will be installed is completely powered off and unplugged.
- Locate IntelliSlot Bay: Identify the dedicated IntelliSlot bay on your Vertiv device.
- Insert RDU120 Card: Carefully slide the RDU120 Network Card into the IntelliSlot bay until it is fully seated. Ensure the front panel aligns with the device's chassis.
- محفوظ ڪارڊ: Use any provided screws or retention clips to secure the card in place.
- نيٽ ورڪ ڪيبل ڳنڍيو: Connect a standard Ethernet cable from your network switch or router to the Ethernet port on the RDU120 front panel.
- Power On Host Device: Reconnect power to the Vertiv equipment and power it on. The RDU120 will initialize with the host device.
5.2 شروعاتي ترتيب
Upon initial power-up, the RDU120 will typically obtain an IP address via DHCP. If DHCP is not available or a static IP is required, refer to the detailed configuration guide available on the Vertiv support webسائيٽ.
- تائين رسائي Web انٽرفيس: کوليو a web browser and enter the IP address of the RDU120. If DHCP is used, you may need to use a network scanner or the host device's interface to find the assigned IP.
- ڊفالٽ سندون: Use the default username and password provided in the product documentation for initial login. Change these immediately for security.
- نيٽ ورڪ سيٽنگون: Configure static IP address, subnet mask, gateway, and DNS servers as per your network requirements.
6. آپريٽنگ
6.1 Web انٽرفيس نيويگيشن
The RDU120's web interface provides comprehensive control and monitoring capabilities. Navigate through the menus to access various settings and data points.
- ڊيش بورڊ: اوور مهيا ڪري ٿوview of system status, alarms, and key parameters.
- نگراني: View real-time data, historical trends, and sensor readings.
- ٺاھ جوڙ: Adjust network settings, user accounts, and communication protocols.
- Alarms & Notifications: Set up alarm thresholds and configure email/text message alerts.
6.2 Monitoring Data
The RDU120 supports various protocols for data integration with Building Management Systems (BMS) and network monitoring tools.
- SNMP (سادي نيٽ ورڪ مئنيجمينٽ پروٽوڪول): Use SNMP v1/v2c/v3 for polling data and receiving traps. Refer to the MIB file for OID definitions.
- موڊبس: Access data via Modbus TCP/IP. Consult the Modbus register map for details.
- BACnet: Integrate with BACnet/IP systems for building automation.
6.3 Alarm and Notification Management
Configure the RDU120 to send alerts for critical events:
- Define alarm thresholds for monitored parameters (e.g., temperature, voltag۽.
- Configure email recipients and SMTP server settings for email notifications.
- Set up SMS gateway for text message alerts (if supported by your service provider).
6.4 ماحولياتي نگراني
When connected to compatible Geist Sensors, the RDU120 can monitor environmental conditions:
- درجه حرارت ۽ نمي: Monitor ambient conditions in server racks or rooms.
- ليڪ جي چڪاس: Detect water leaks to prevent equipment damage.
- Door Closures: Monitor access to cabinets or rooms.
7. سار سنڀال
7.1 فرم ویئر تازه ڪاريون
Regularly check the Vertiv support webجديد فرم ويئر اپڊيٽس لاءِ سائيٽ. فرم ويئر اپڊيٽس نوان خاصيتون، ڪارڪردگي بهتري، ۽ سيڪيورٽي واڌارا مهيا ڪري سگھن ٿا.
- مناسب firmware ڊائون لوڊ ڪريو file from the Vertiv webسائيٽ.
- Access the firmware update section in the RDU120 web انٽرفيس.
- Follow the on-screen instructions to upload and install the firmware. Do not power off the device during the update process.
7.2 سسٽم بيڪ اپ ۽ بحالي
It is recommended to back up the RDU120's configuration settings periodically, especially before major changes or firmware updates.
- Export configuration settings from the web انٽرفيس.
- Store the backup file هڪ محفوظ هنڌ ۾.
- Use the restore function to revert to a previous configuration if needed.
8. مسئلا حل ڪرڻ
This section provides solutions to common issues you might encounter with the RDU120 Network Card.
| مسئلو | ممڪن سبب | حل |
|---|---|---|
| رسائي نه ٿو ڪري سگھجي web انٽرفيس. | غلط IP پتو؛ نيٽ ورڪ ڪنيڪٽوٽي جو مسئلو؛ فائر وال جي رسائي کي بلاڪ ڪرڻ. | Verify IP address; Check network cable and switch; Disable temporary firewall for testing; Ensure RDU120 is powered on. |
| No data via SNMP/Modbus/BACnet. | Protocol not enabled; Incorrect configuration; Network routing issue. | Ensure protocol is enabled in RDU120 settings; Verify IP addresses and port numbers; Check network routes and firewalls. |
| Alarms not being sent. | Incorrect notification settings; SMTP server issues; Email address errors. | Verify alarm thresholds and notification recipients; Test SMTP server connectivity; Check spam folders. |
| Card not detected by host device. | Card not fully seated; Incompatible host device; Card malfunction. | Reseat the card firmly; Consult host device compatibility list; Contact Vertiv support if issue persists. |
For more complex issues, refer to the comprehensive troubleshooting guide on the Vertiv support website or contact Vertiv technical support.
9. وضاحتون
Technical specifications for the Vertiv Liebert IntelliSlot RDU120 Network Card:
| وصف | قدر |
|---|---|
| پيداوار جي ماپ | 5.2 x 2.97 x 1.45 انچ |
| شيءِ جو وزن | 5.9 اونس |
| ASIN | B0F2MN6WTB |
| شيون ماڊل نمبر | آر ڊي يو 120 |
| تاريخ پهرين دستياب | مارچ 27، 2025 |
| ٺاهيندڙ | ورٽيو |
| برانڊ | ورٽيو |
| يو پي سي | 767041039627 |
10. وارنٽي ۽ سپورٽ
10.1 وارنٽي ڄاڻ
Vertiv products are backed by a standard limited warranty. For specific warranty terms and conditions applicable to your RDU120 Network Card, please refer to the warranty documentation included with your purchase or visit the official Vertiv webسائيٽ.
10.2 ٽيڪنيڪل سپورٽ
For technical assistance, product inquiries, or troubleshooting beyond the scope of this manual, please contact Vertiv Technical Support. Support contact information can be found on the official Vertiv webسائيٽ:
Vertiv Official Webسائيٽ: www.vertiv.com
Please have your product model number (RDU120) and serial number ready when contacting support.