ENTTEC 73539 DIN PIXIE
پيداوار جي ڄاڻ
وضاحتون:
- ڪسٽم پروٽوڪول ٺاھڻ جي ھدايت
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
پيداوار جي استعمال جون هدايتون
تعارف:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
سيٽ اپ گهرجون:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
مطابقت رکندڙ فرم ویئر
ڪسٽم پروٽوڪول ٺاھڻ ھيٺ ڏنل ENTTEC پکسل سنڀاليندڙن ۾ ڏيکاريل آھي:
| SKU | پيداوار | فرم ویئر نسخو |
| 73539 | DIN PIXIE | V2.0 يا مٿي |
| 70067 | PIXELATOR MINI | V2.0 يا مٿي |
| 70068 | پڪسيليٽر مني MK2 | V1.0 يا مٿي |
| 71521 | OCTO MK2 | V4.0 يا مٿي |
| 71522 | OCTO MK3 | V1.0 يا مٿي |
تعارف
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- هي مضمون صارفين کي حجم کي ترتيب ڏيڻ جي قابل بڻائي ٿوtage ٽائمنگ سپورٽ ٿيل پروٽوڪول جي بنياد تي جيڪڏهن ڊيٽا ٽرانسميشن جو طريقو اسان جي سپورٽ ڪيل پروٽوڪولن مان ڪنهن سان ملندو آهي.
- هي دستاويز هڪ ڪسٽم پکسل پروٽوڪول ٺاهڻ ۽ معيار جي تصديق ڪرڻ لاءِ سيٽ اپ جون هدايتون مهيا ڪري ٿو.
سيٽ اپ گهربل
ڪسٽم پروٽوڪول ٺاھڻ لاءِ ھيٺيون شيون گھربل آھن:
- ڊيٽا شيٽ: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- ڊوائيس: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
ڪسٽم پروٽوڪول ٺاھڻ جي ھدايت
هي خاصيت صارفين کي ڊيٽا جي حجم کي ترتيب ڏيڻ جي اجازت ڏئي ٿيtage timing to meet specific protocol needs. To create a custom protocol:
- مطابقت واري پکسل پروٽوڪول لاءِ ڊيٽا شيٽ جي تصديق ڪريو.
- ڪسٽم پروٽوڪول فيچر کي فعال ڪرڻ لاءِ ڊوائيس جي يوزر انٽرفيس ڏانھن وڃو.
- پکسل فيڪٽر جي ڊيٽا حجم کي ترتيب ڏيوtage وقت ذريعي web ٺاهيندڙ جي ڊيٽا شيٽ جي مطابق انٽرفيس.
قدم 1: مطابقت واري پروٽوڪول لاءِ ڊيٽا شيٽ جي تصديق ڪريو
- ڊيٽا شيٽ مان توهان جي گهربل پروٽوڪول جي ڊيٽا ٽرانسميشن جي طريقي جي تصديق ڪريو.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- سڀ کان وڌيڪ عام طريقو ڊيٽا کي بغير اضافي بٽ منتقل ڪري ٿو (مثال طور، D1-D2-D3…Dn).
Example: ڄاڻ ورتي وئي WB2812B جي ڊيٽ شيٽ مان
- ڪجهه پروٽوڪول، جهڙوڪ TM1814، شامل آهن اضافي ڊيٽا اڳيان (مثال طور، C1-C2-D1-D2…Dn).
Example: ڄاڻ ورتي وئي TM1814 جي ڊيٽ شيٽ مان
- سڀ کان وڌيڪ عام طريقو ڊيٽا کي بغير اضافي بٽ منتقل ڪري ٿو (مثال طور، D1-D2-D3…Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- ڊيوائس پاران سپورٽ ڪيل ملندڙ پروٽوڪول کي نامزد ڪريو (يا مٿين مان چونڊيو example) that shares the same data transmission method as your desired pixel protocol.
- وڌيڪ تشڪيل لاءِ قدم 2 ڏانھن وڃو.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web انٽرفيس
- گوگل ڪروم جي طور تي تجويز ڪيل آهي web browser to access the OCTO/PIXELATOR MINI’s web انٽرفيس.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webايپ ڊائون لوڊ ڪرڻ لاءِ سائيٽ www.enttec.com.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
آئوٽ ڏانھن وڃو جتي مطلوب پکسل فيڪٽر سان ڳنڍيل آھي. ڊراپ ڊائون لسٽ مان هڪ پکسل پروٽوڪول چونڊيو جيڪو ساڳيو ٽرانسميشن جو طريقو شيئر ڪري ٿو قدم 1 ۾ تصديق ٿيل.
- Enable Custom protocol (Continue to Step 3)
ڊيٽا حجم تائين رسائي حاصل ڪرڻ لاءِ 'ڪسٽم' ٽڪ باڪس کي فعال ڪريوtage وقت جي ترتيب. ڪسٽم پروٽوڪول کي غير فعال ڪرڻ لاءِ چيڪ ڪريو.
DIN PIXIE لاءِ
- DIN PIXIE کي USB قسم-B استعمال ڪندي ڪمپيوٽر سان ڳنڍيو.
- EMU سافٽ ويئر لانچ ڪريو.
- ڊوائيس لاء اسڪين ڪريو ۽ دريافت ڪيل DIN PIXIE جي Conf تي ڪلڪ ڪريو.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
مرحلا 3: حسب ضرورت سيٽ ڪريوtage وقت
- حجم سان ملائيtagتوهان جي گهربل پروٽوڪول جي ڊيٽا شيٽ تي وقت. ڪسٽم پروٽوڪول جي ضرورت آهي 4 ان پٽن کي مڪمل ڪرڻ لاءِ ڊيٽا حجمtagوقت جي ترتيب:
جلدtage Timing Definition بٽ 0 هاءِ ٽائيم (T0H) جلدtagڪوڊ 0 لاءِ وڌيڪ وقت گھربل آھي. بٽ 1 هاءِ ٽائيم (T1H) جلدtagڪوڊ 1 لاءِ وڌيڪ وقت گھربل آھي. Overall Bit Time: ڪل حجمtage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
ري سيٽ وقت ڪل حجمtagهر ڊيٽا بيچ جي وچ ۾ ڊيٽا ٽرانسميشن کي ري سيٽ ڪرڻ لاء گهٽ وقت گهربل. 
- ڊيٽا شيٽ - ڊيٽا جلدtage وقت جي معلومات Example
WB2818B جي ڊيٽ شيٽ مان- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage وقت جي حد.
- حجم ڀريوtagاي وقت جي حد ڪسٽم فيلڊ ۾ آئوٽ پٽ سيٽنگون ۾.

اهم
- ENTTEC recommends taking the median value of the range for the start.
- استعمال ڪندڙ کي تبديل ٿيل قدر کي اثر انداز ڪرڻ لاءِ سيٽنگون بچائڻو پوندو.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
نتيجو
- هن گائيڊ ڏيکاريو ته ڪيئن هڪ ڪسٽم پروٽوڪول قائم ڪجي اهل ENTTEC ڊوائيسز لاءِ ۽ توهان جي گهربل پکسل فيڪسچر جي ڊيٽا شيٽ جي تصديق ڪرڻ تي ٽيڪنيڪل ڄاڻ مهيا ڪئي.
- انهن قدمن تي عمل ڪندي، صارف هڪ ڪسٽم پکسل پروٽوڪول ٺاهي سگھن ٿا جيڪو ڊراپ-ڊائون لسٽ ۾ نه مليو آهي بغير ٽيڪنيڪل سپورٽ يا نئين فرم ويئر رليز جي انتظار جي. جيڪڏهن توهان وٽ سوال آهي يا صحيح معلومات ڳولڻ ۾ مشڪل آهي، مقامي آفيسن تي اسان جي دوستانه سپورٽ ٽيم سان رابطو ڪريو.
FAQ
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web برائوزر.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
دستاويز / وسيلا
![]() |
ENTTEC 73539 DIN PIXIE [pdf] هدايت نامو DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |