invt EC-PG805 TTL Incremental Encoder PG Expansion Module

اڳڪٿي
Thank you for choosing the INVT EC-PG805-05 TTL incremental encoder PG expansion module. The EC-PG805-05 TTL incremental encoder PG expansion module is used with the GD880 series VFD control box to detect the TTL or RS422 incremental encoder. The expansion module monitors the rotational speed of the motor by detecting the output signal of the encoder, providing real-time speed feedback for precise speed control. This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read through this manual carefully to ensure proper installation and running with excellent performance and powerful functions in full play.
پيداوار جون خاصيتون
- Incremental encoder multi-channel signal detection: IA+, IA -, IB+, IB -, IZ+, IZ-
- Provides power supply for encoders: 5V±5%/150mA
- Supports two input signal types: TTL differential signal input, RS422 signal input
- پلس ريفرنس ۽ فریکوئنسي ڊويزن جي پيداوار کي سپورٽ ڪري ٿو
- With the encoder disconnection detection function, it avoids the expansion of the system fault impact
- KTY84 / PT100 گرمي پد سينسر سگنل ذريعي موٽر جي درجه حرارت کي ڳولڻ جي قابل
- Adopts digital filtering technology to improve electromagnetic compatibility and realize long-distance stable reception of encoder signals.
پيداوار ختمview
ماڊل جي وضاحت

وضاحتون

جدول 1-1 وضاحتون
ٽيڪنيڪل پيراگراف

ٽيبل 1-2 ٽيڪنيڪل پيراگراف
نوٽ: The Disconnection detection function is only supported when the motor is running.
ساخت
Figure 1-2 Component diagram

ٽيبل 1-3 اجزاء جي وضاحت

تنصيب ۽ وائرنگ
تنصيب جي احتياط
Required tools: Phillips screwdriver PHl, straight screwdriver SL3

ٽيبل 2-1 Screw torque requirements

طول و عرض
The dimensions of the PG expansion module are 73.5x 103 x 34 mm (W*H*D).

انسٽاليشن هدايتون

It is recommended to place the PG expansion module in expansion slot 1 of the control box. The following is an exampسلاٽ 1 تي تنصيب جي le.
قدم 1: توسيع واري ماڊل کي ڪنٽرول باڪس جي توسيع واري سلاٽ 1 جي لاڳاپيل پوزيشن ۾ رکو، ان کي سلاٽ سان ترتيب ڏيو، ۽ پوءِ ان کي گڏ ڪريو.
قدم 2: Align the expansion module positioning hole with the positioning stud.
قدم 3:F: Fix with an M3 screw. The installation is complete.
نوٽ
- توسيع ماڊل ۽ ڪنٽرول باڪس برقي طور تي سلاٽ ذريعي ڳنڍيل آهن. مھرباني ڪري انھن کي جڳھ ۾ انسٽال ڪريو.
- توسيع واري ماڊل جي قابل اعتماد آپريشن کي يقيني بڻائڻ ۽ EMC گهرجن کي پورو ڪرڻ لاءِ، مهرباني ڪري قابل اعتماد گرائونڊنگ لاءِ تجويز ڪيل ٽوڪ مطابق پيچ کي سخت ڪريو.
ڌار ڪرڻ جون هدايتون
You disassemble the module by reversing the order of steps described in section 2.3 Installation instructions.
قدم 1: Disconnect all power supplies and disassemble all cables connected to the expansion module.
قدم 2: Use a Phillips screwdriver PHl to remove the grounding screws of the expansion module.
قدم 3: Lift the expansion module out of the control box, positioning stud, and pull it out to a suitable position. Disassembly is complete.
استعمال ڪندڙ جي وائرنگ ٽرمينل


نوٽ
- The number of the PG extension module that supports the KTY84 type and that supports the PT100 type are different. Please note this when placing an order.
- The PG expansion module supports one PT100 or three PT100s for use in series.
ٽيبل 2-3 X4 ٽرمينل فنڪشن تعريف

Table 2-4 Function definition of RJ45 interfaces X1-X2

Figure 2-3 External wiring diagram when using EC-PG805-05

نوٽ: For the PT100 temperature sensor application (in a 3-channel series connection), J3 should be shortened.
وائرنگ جي احتياط
نوٽ
- انڪوڊر وائرنگ لاءِ ڪابينا اندر، انھن کي مضبوط مداخلت واري ڪيبل (جهڙوڪ پاور ڪيبل) کان 30 سينٽي ميٽر جي تجويز ڪيل وقفي سان الڳ ڪريو.
- ڪابينا جي ٻاهران انڪوڊر وائرنگ لاءِ، پاور ڪيبل سان متوازي وائرنگ کان پاسو ڪريو ۽ انگوزي جي شڪل ٺاھڻ کان پاسو ڪريو. جيڪڏهن حالتون اجازت ڏين ٿيون، اهو وائرنگ لاء هڪ ڌاتو ڪنڊ استعمال ڪرڻ جي صلاح ڏني وئي آهي.
- To ensure high anti-interference capability in closed-loop control, you need to use a shielded wire for encoder cables and ground both ends of the cable, that is, connect the shielding layer on the motor side to the motor housing, and connect the shielding layer on the PG module side to the PE terminal.
ڪم ڪرڻ جي هدايت


Table 3-1 Function code parameters related to PG expansion module.


نوٽ: For other parameter settings of the EC-PG805-05 TTL incremental encoder PG expansion module, see the software manuals of the GD880 series inverter unit.
دستاويز / وسيلا
![]() |
invt EC-PG805 TTL Incremental Encoder PG Expansion Module [pdf] استعمال ڪندڙ دستياب 66001-01189, EC-PG805 TTL Incremental Encoder PG Expansion Module, EC-PG805, TTL Incremental Encoder PG Expansion Module, Incremental Encoder PG Expansion Module, Encoder PG Expansion Module, PG Expansion Module, Expansion Module, Module |