LEDCTRL Flexible Neon LED Ctrl

وضاحتون
- Product Name: Silicone Diffuser Free Bend LED linear Light
- Material: PVC, Silicone, Metal
- بجلي جي فراهمي: ڊيڪس اين اينيمڪس وي
- Minimum Bending Diameter: 1200mm(Horizontal/Vertical)
- Cable Exit Options: End, Bottom, Side
پيداوار جي استعمال جون هدايتون
- The slotting length should be 50mm from the beginning + ProductLength + 50mm at the end. Ensure to create an extra slot for thecable conduit.
- Follow instructions to create proper drainage holes for the cement layer, roadbed, and permeable layer.
- مناسب پرو چونڊيوfile type and use joining brackets to secure them. Tighten the bracket with a screwdriver.
- پرو کي ڪٽيوfile according to the provided guidelines. Drill an adjoining hole if needed after cutting.
- Cut a hole in the rubber grommet for the cable exit and install the end cover and connector accordingly.
- Install fixing brackets as recommended and tighten them securely after the cement solidifies.
- Place the PVC protection cover to shield the profile ملبے کان.
- Ensure the cable is sheathed in the conduit to prevent cement hardening around it.
- Fill the ground with cement until it’s level with the surface.
- Clean the slot after removing the PVC protection cover.
- Connect and test the light before installation. Hide the cable and connector down the raceway.
- Install the light in place and test its functionality.
- Apply structural adhesive to secure the silicone diffuser in place.
اجزاء

تنصيب جون هدايتون
قدم 1
سلاٽنگ

قدم 2
- DRAINAGE LAYER CONSTRUCTION

Step 3 PROFILE شامل ٿيڻ

Step 4 PROFILE ڪٽڻ
نوٽ: drill a Φ10mm joining hole on the center of the last section of the profile if joining profiles is required after cutting.

Step 5: INSTALLATION OF END COVER & CONNECTOR
- Cut a hole in the rubber grommet that best fits the cable.

Step 6: INSTALLATION OF FIXING BRACKET
پاسي View
- After the cement solidifies, hammer the wall plug into the fixing hole measured by the installation shape.

مٿو View
- Recommend 6pcs fixing brackets per 1m and they should be spaced evenly on alternate sides

- Then tighten the fixing brackets with screws.

Step 7: INSTALLATION OF PVC PROTECTION COVER
- Put the PVC protection cover in place to protect the profile ملبے کان.

Step 8: INSTALLATION OF CABLE CONDUIT

- Sheathe the cable in the cable conduit completely to keep cement from hardening and jamming the cable.

Step 9 FILLING CEMENT
- Refill the ground until it’s level with the product surface.

Step 10: REMOVING THE PVC PROTECTION COVER
- Clean the slot after removing the cover.

Step 11: INSTALLATION OF FREE BEND LIGHT
نوٽ: Energize and test the light before the installation.

Step 12 LIGHTING TEST

Step 13 GLUE
- Apply the structural adhesive along the edge of the profile at both ends, a length to be glued around 5cm to prevent the silicone diffuser from being stolen.
- Adhesives such as DowCorning SJ168, 791, and 995 are highly recommended for this purpose.

Step 14 PLACING THE SILICONE DIFFUSER

Maintenance & Replacement of In-Ground Lights
Regular maintenance, systematic troubleshooting, and the use of standardized replacement components ensure long-term reliability, safety, and optimal performance of in-ground lighting systems.
روزاني سار سنڀال
- تعدد:
- Every 3-6 months (or immediately after extreme weather events such as earthquakes, heavy storms, floods, typhoons, or ice storms)
چڪاس جي چڪاس
Surface Debris
- Remove dirt, mud, leaves, or other obstructions blocking light emission
هلڪو ڪارڪردگي
- Check for flickering, dimming, or complete failure.
جسماني نقصان
- Inspect for cracks, deep scratches, or signs of impact on the silicone cover
Junction Box Integrity
- Verify waterproof connectors are intact with no aging or deterioration
تجويز ڪيل طريقو
Use a soft cloth with a neutral cleaner (avoid abrasive brushes or harsh chemicals).
Alternative Method (High-Pressure Cleaning)
A water jet gun is recommended for a deep, intensive cleaning. Cleaning machines are also advisable, provided the in-ground light can withstand the weight.
- Rinsing Pressure: 20-80bar (290-1160psi).
- Nozzle: fan nozzles only (disperses pressure); zero-degree nozzles may cause surface damage.
- Distance: 30-50cm. (can be 15cm for stubborn stains for 20-30 seconds max).
- Water Temperature: ≤40ºC (room temp or lukewarm).
متبادل هدايتون
متبادل حالتون
- Silicone Cover Damage: Cracks, deep dents (>3mm), or permanent stains affecting light output.
- Light Failure: flickering, dimming, extinguishing, or dead LEDs or no illumination at all.
STEP-BY-STEP REPLACEMENT
Critical Reminders:
- NEVER stretch the silicone cover before cutting it.
- نقصان کان بچڻ لاءِ گھڻي طاقت کان پاسو ڪريو.
- Clean the channel before reinstalling the cover.
| A. Silicone Cover Replacement |
| 1) Remove Old Cover. Use a screwdriver to pry open the cover from one end. Gently pull it out along the profile. |
| 2) Align Length & Cut New Cover |
| 3) Install New Cover: Install the new silicone cover and ensure it fits evenly along the profile. |
| B. Light Replacement | |
| 1) Power Off | Disconnect electricity completely. |
| 2) Locate the Faulty Light | Identify the exact position where the light needs replacement. |
| 3) Remove Silicone Cover | Follow step 1) in Section A. |
| 4) Extract Defective Light | Remove the failed light. |
| 5) Pre-Install | Test the new light before installation. |
| 6) Install New Light | Match polarity and ensure connectors are clean and dry. |
| 7) Post-Install | Restore power and test the new light again. |
| 8) Reinstall Silicone Cover | Carefully reposition the cover and ensure it fits evenly along the entire profile. |
رابطو ڪريو
- ڊبليو
- LED CTRL, 1/483 BALMAIN
- LILYFIELD, NSW 2040, AUSTRALIA
- وضاحتون تبديل ڪرڻ جي تابع
- WITHOUT NOTICE, VISIT ڊبليو
- سڀ کان وڌيڪ موجوده وضاحتن لاء.
- LED CONTROL PTE LTD UEN 201923077G
- 2025 LEDCTRL ALL RIGHTS RESERVED
FAQ
Q: What type of adhesive is recommended for installing the silicone diffuser?
A: Adhesives such as Dow Corning SJ168, 791, and 995 are highly recommended for securing the silicone diffuser.
Q: How many fixing brackets should be used per meter during installation?
A: It is recommended to use 6 fixing brackets per meter, spaced evenly on alternate sides for secure installation.
دستاويز / وسيلا
![]() |
LEDCTRL Flexible Neon LED Ctrl [pdf] انسٽاليشن گائيڊ FXNInGround, FX_FXNInGround, Flexible Neon LED Ctrl, Neon LED Ctrl, LED Ctrl |